A planar PDMS micropump using in-contact minimized-leakage check valves

被引:31
|
作者
Ni, Junhui [1 ,2 ]
Huang, Fengliang [2 ,3 ]
Wang, Bin [2 ]
Li, Beizhi [1 ]
Lin, Qiao [2 ]
机构
[1] Donghua Univ, Coll Mech Engn, Shanghai, Peoples R China
[2] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[3] Nanjing Normal Univ, Sch Elect & Automat Engn, Nanjing, Peoples R China
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
THERMOPNEUMATIC-ACTUATED MICROPUMP; SYSTEMS; FUTURE;
D O I
10.1088/0960-1317/20/9/095033
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a micropump with a simple planar design featuring compliant in-contact check valves in a single layer, which allows for a simple structure and easy system integration. The micropump, based on poly(dimethylsiloxane) (PDMS), primarily consists of a pneumatically driven thin membrane, a pump chamber, and two in-plane check valves. The pair of check valves is based on an in-contact flap-stopper configuration and is able to minimize leakage flow, greatly enhancing the reliability and performance of the micropump. Systematic experimental characterization of the micropump has been performed in terms of the frequency response of the pumping flow rate with respect to factors including device geometry (e. g. chamber height) and operating parameters (e. g. pneumatic driving pressure and backpressure). The results demonstrate that this micropump is capable of reliably generating a maximum flow rate of 41 mu L min(-1) and operating against a high backpressure of up to 25 kPa. In addition, a lumped-parameter theoretical model for the planar micropump is also developed for accurate analysis of the device behavior. These results demonstrate the capability of this micropump for diverse applications in lab-on-a-chip systems.
引用
收藏
页数:7
相关论文
共 8 条
  • [1] A MEMS-based PDMS Micropump Utilizing Electromagnetic Actuation and Planar In-contact Check Valves
    Ni, Junhui
    Li, Beizhi
    Yang, Jiangguo
    MANUFACTURING ENGINEERING AND AUTOMATION I, PTS 1-3, 2011, 139-141 : 1574 - 1577
  • [2] A magnetically driven PDMS micropump with ball check-valves
    Pan, TR
    McDonald, SJ
    Kai, EM
    Ziaie, B
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2005, 15 (05) : 1021 - 1026
  • [3] RESONANTLY DRIVEN PIEZOELECTRIC MICROPUMP WITH PDMS CHECK VALVES AND COMPRESSIBLE SPACE
    Ma, Yu-ting
    Wang, Xue-yan
    Zhong, Jin-feng
    Feng, Zhi-hua
    2014 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES, AND DEVICE APPLICATIONS (SPAWDA), 2014, : 158 - 161
  • [4] A pneumatic PDMS micropump with in-plane check valves for disposable microfluidic systems
    Ni, Junhui
    Li, Beizhi
    Yang, Jianguo
    MICROELECTRONIC ENGINEERING, 2012, 99 : 28 - 32
  • [5] Planar microfabricated check valves utilizing large compliance of PDMS
    Yang, Bozhi
    Lin, Qiao
    MICRO-ELECTRO-MECHANICAL SYSTEMS - 2005, 2005, 7 : 737 - 740
  • [6] Assembly and Simple Demonstration of a Micropump Installing PDMS-Based Thin Membranes as Flexible Micro Check Valves
    Tanaka, Yo
    Sato, Kae
    Kitamori, Takehiko
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2009, 5 (05) : 516 - 520
  • [7] Root cause detection of leakage in check valves using multi-scale signal analysis
    Tong, Chengbiao
    Sepehri, Nariman
    Zhou, Jiang
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (01) : 55 - 67
  • [8] Root cause detection of leakage in check valves using multi-scale signal analysis
    Chengbiao Tong
    Nariman Sepehri
    Jiang Zhou
    Journal of Mechanical Science and Technology, 2023, 37 : 55 - 67