Microchannel evaporators of the residential air-conditioner

被引:0
|
作者
Cho, Honggi [1 ]
Cho, Keumnam [1 ]
机构
[1] Sungkyunkwan Univ, Sch Mech Engn, Seoul 110745, South Korea
关键词
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The objective of present work was to evaluate the performance of microchannel evaporators of the residential air-conditioner using R-22. Six prototype evaporators were manufactured and tested with psychrometric calorimeter test facilities. The test was conducted in two different ways. Each evaporator consisted of two parallel flow type heat exchangers connected with several return pipes. The heat exchanger had 41 microchannel tubes that had 8 rectangular ports with the hydraulic diameter of 1.3 mm. For the vapor compression system(VCS), the flow area ratio and the number of return pipe had a great effect on the cooling capacity. Type 3 with the flow area ratio of 73/58% showed best cooling capacity. The effect of the number of circuit and merging manifold on the cooling capacity was relatively small. For the refrigerant circulation system(RCS), the cooling capacity of the test evaporators was a little bit changed as the mass flow rate and inlet quality increased. The effect of mass flow rate on the cooling capacity was slightly superior to that of inlet quality. The effect of the number of circuit on the cooling capacity was different with the result of the VCS, while the effect of merging manifold was negligible. The cooling capacity proportionally increased as the vertical inclination angle of the evaporator increased due to gravity force.
引用
收藏
页码:625 / 630
页数:6
相关论文
共 50 条
  • [1] DISTURBANCE CAUSED BY RESIDENTIAL AIR-CONDITIONER NOISE
    BRADLEY, JS
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1993, 93 (04): : 1978 - 1986
  • [2] Towards a Residential Air-Conditioner Usage Model for Australia
    Goldsworthy, Mark
    [J]. ENERGIES, 2017, 10 (09):
  • [3] Residential air-conditioner usage in China and efficiency standardization
    Wu, Jianghong
    Liu, Chaopeng
    Li, Hongqi
    Ouyang, Dong
    Cheng, Jianhong
    Wang, Yuanxia
    You, Shaofang
    [J]. ENERGY, 2017, 119 : 1036 - 1046
  • [4] THE AIR-CONDITIONER ILLNESS
    BRESTOWSKI, J
    GRALL, Y
    AIACHE, JM
    MENAUT, P
    MOLINA, C
    [J]. REVUE FRANCAISE D ALLERGOLOGIE ET D IMMUNOLOGIE CLINIQUE, 1981, 21 (4-5): : 221 - 225
  • [5] TREE AS AIR-CONDITIONER
    HALLER, JM
    [J]. AMERICAN HORTICULTURAL MAGAZINE, 1969, 48 (02): : 79 - &
  • [6] AIR-CONDITIONER DISEASE
    BRESTOWSKI, J
    GRALL, Y
    AIACHE, JM
    MENAUT, P
    MOLINA, C
    [J]. REVUE FRANCAISE D ALLERGOLOGIE ET D IMMUNOLOGIE CLINIQUE, 1982, 22 (01): : 41 - 41
  • [7] MODELING OF A SOLAR-ASSISTED DESICCANT AIR-CONDITIONER FOR A RESIDENTIAL BUILDING
    SMITH, RR
    HWANG, CC
    DOUGALL, RS
    [J]. ENERGY, 1994, 19 (06) : 679 - 691
  • [8] New absorption air-conditioner
    Chekir, Nihel
    [J]. 2014 5TH INTERNATIONAL RENEWABLE ENERGY CONGRESS (IREC), 2014,
  • [9] REDUCING AIR-CONDITIONER NOISE
    不详
    [J]. BATTELLE TECHNICAL REVIEW, 1968, 17 (08): : 24 - &
  • [10] Green air-conditioner design
    Qiu Haitao
    Wu Yan
    Sun Shouqian
    [J]. 7TH INTERNATIONAL CONFERENCE ON COMPUTER-AIDED INDUSTRIAL DESIGN & CONCEPTUAL DESIGN, 2006, : 466 - 469