Rotational positioning of the tibial tray in total knee arthroplasty: A CT evaluation

被引:27
|
作者
Berhouet, J. [1 ,2 ]
Beaufils, P. [1 ]
Boisrenoult, P. [1 ]
Frasca, D. [3 ]
Pujol, N. [1 ]
机构
[1] Versailles St Quentin Univ, Andre Mignot Hosp, Versailles Hosp Ctr, Dept Orthopaed & Trauma, F-78157 Le Chesnay, France
[2] Univ Tours, Trousseau Univ Reg Hosp Ctr, Dept Orthopaed & Trauma, F-37170 Chambray Les Tours, France
[3] Univ Poitiers, La Miletrie Univ Hosp Ctr, Dept Anaesthesia & Intens Care, F-86021 Poitiers, France
关键词
Knee; Total knee arthroplasty; Tibial rotation; Computed tomography scanning (CT scanning); Tibial component positioning; FEMORAL COMPONENT; PATELLAR TRACKING; DISTAL FEMUR; ALIGNMENT; AXIS; REPLACEMENT; LANDMARKS; ANATOMY; SCAN;
D O I
10.1016/j.otsr.2011.05.006
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Various surgical techniques have been described to set the rotational alignment of the tibial baseplate during total knee arthroplasty. The self-positioning method ("self-adjustment'') aligns the tibial implant according to the rotational alignment of the femoral component which is used as a reference after performing repeated knee flexion/extension cycles. Postoperative computed tomography scanning produces accurate measurements of the tibial baseplate rotational alignment with respect to the femoral component. Hypothesis: The rotational positioning of the tibial baseplate matches the rotation of the femoral component with parallel alignment to the prosthetic posterior bicondylar axis. Patients and methods: A 3-month follow-up CT scan was carried out after primary total knee arthroplasty implanted in osteoarthritic patients with a mean 7.8 degrees varus deformity of the knee in 50 cases and a mean 8.7 degrees valgus deformity of the knee in 44 cases. The NexGen LPS Flex (Zimmer) fixed-bearing knee prosthesis was used in all cases. An independant examiner (not part of the operating team) measured different variables: the angle between the anatomic transepicondylar axis and the posterior bicondylar axis of the femoral prosthesis (prosthetic posterior condylar angle), the angle between the posterior bicondylar axis and the posterior marginal axis of the tibial prosthesis, the angle between the posterior marginal axis of the tibial prosthesis and the posterior marginal axis of the tibial bone and finally the angle between the anatomic transepicondylar axis and the posterior marginal axis of the tibial prosthesis. Results: For the genu varum and genu valgum subgroups, the mean posterior condylar axis of the femoral prosthesis was 3.1 degrees (SD: 1.91; extremes 0 degrees to 17.5 degrees) and 4.7 degrees (SD: 2.7; extremes 0 degrees to 11 degrees) respectively. The tibial baseplate was placed in external rotation with respect to the femoral component: 0.7 degrees (SD : 4.45; extremes -9.5 degrees to 9.8 degrees) and 0.9 degrees (SD: 4.53; extremes -10.8 degrees to 9.5 degrees), but also to the native tibia: 6.1 degrees (SD: 5.85; extremes -4.6 degrees to 22.5 degrees) and 12.5 degrees (SD: 8.6; extremes -10 degrees to 28.9 degrees). The tibial component was placed in internal rotation relative to the anatomic transepicondylar axis: 1.9 degrees (SD : 4.93; extremes -13.6 degrees to 7 degrees) and 3 degrees (SD : 4.38; extremes -16.2 degrees to 4.8 degrees). Discussion: The tibial component is aligned parallel to the femoral component whatever the initial frontal deformity (P congruent to 0.7). However, a difference was observed between the rotational alignment of the tibial baseplate and the native tibia depending on the initial deformity and could be attributed to the morphological variations of the bony tibial plateau in case of genu valgum. Conclusion: The self-positioning method is a reproducible option when using this type of implant since it allows the tibial component to be positioned parallel to the posterior border of the femur. Level of evidence: Level III. Observational prospective study. (C) 2011 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:699 / 704
页数:6
相关论文
共 50 条
  • [1] Fracture of the tibial tray after total knee arthroplasty
    Altintas, F
    Sener, N
    Ugutmen, E
    [J]. JOURNAL OF ARTHROPLASTY, 1999, 14 (01): : 112 - 114
  • [2] Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver study
    Rossi, Roberto
    Bruzzone, Matteo
    Bonasia, Davide Edoardo
    Marmotti, Antonio
    Castoldi, Filippo
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2010, 18 (07) : 889 - 893
  • [3] Evaluation of tibial rotational alignment in total knee arthroplasty: a cadaver study
    Roberto Rossi
    Matteo Bruzzone
    Davide Edoardo Bonasia
    Antonio Marmotti
    Filippo Castoldi
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 889 - 893
  • [4] Total Knee Arthroplasty With Asymmetric Femoral Condyles and Tibial Tray
    Crockarell, John R., Jr.
    Hicks, John M.
    Schroeder, R. Jason
    Guyton, James L.
    Harkess, James W.
    Lavelle, David G.
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (01): : 108 - 113
  • [5] Rotational alignment of the tibial component in total knee arthroplasty
    Bindelglass, DF
    [J]. ORTHOPEDICS, 2001, 24 (11) : 1049 - 1052
  • [6] Rotational alignment of the tibial component in total knee arthroplasty
    Indelli, Pier Francesco
    Graceffa, Angelo
    Marcucci, Massimiliano
    Baldini, Andrea
    [J]. ANNALS OF TRANSLATIONAL MEDICINE, 2016, 4 (01)
  • [7] Effect of tibial tray design on cement morphology in total knee arthroplasty
    Schlegel, Ulf J.
    Pueschel, Klaus
    Morlock, Michael M.
    Nagel, Katrin
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2014, 9 : 123
  • [8] Effect of tibial tray design on cement morphology in total knee arthroplasty
    Ulf J Schlegel
    Klaus Püschel
    Michael M Morlock
    Katrin Nagel
    [J]. Journal of Orthopaedic Surgery and Research, 9
  • [9] Optimal rotational positioning of tibial component in total knee arthroplasty: determined by linker surgical technique using a high definition CT
    Jung, Woon-Hwa
    Seo, Jai-Gon
    Kim, Dong Hyun
    Balabadra, Suryamanikanta
    Mandot, Utkrisht
    Kumar, Dinesh
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (03) : 401 - 408
  • [10] Optimal rotational positioning of tibial component in total knee arthroplasty: determined by linker surgical technique using a high definition CT
    Woon-Hwa Jung
    Jai-Gon Seo
    Dong Hyun Kim
    Suryamanikanta Balabadra
    Utkrisht Mandot
    Dinesh Kumar
    [J]. Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 401 - 408