Automation of the Buccal Micronucleus Cytome Assay Using Laser Scanning Cytometry

被引:19
|
作者
Leifert, Wayne R. [1 ,5 ]
Francois, Maxime [1 ,2 ,5 ]
Thomas, Philip [1 ,5 ]
Luther, Ed [4 ]
Holden, Elena [3 ]
Fenech, Michael [1 ,5 ]
机构
[1] CSIRO Food & Nutr Sci, Genome Hlth Nutrigenom, Adelaide, SA, Australia
[2] Edith Cowan Univ, Ctr Excellence Alzheimers Dis Res & Care, Joondalup, WA, Australia
[3] CompuCyte Corp, Westwood, MA USA
[4] LSC, Wilmington, MA USA
[5] CSIRO Food & Nutr Sci, Nutr Genom & Genome Hlth Diagnost, Adelaide, SA, Australia
关键词
HISTONE H2AX; PHOSPHORYLATION; BREAKAGE; SMOKERS; CELLS;
D O I
10.1016/B978-0-12-374912-3.00013-4
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
Laser scanning cytometry (LSC) can be used to quantify the fluorescence intensity or laser light loss (absorbance) of localized molecular targets within nuclear and cytoplasmic structures of cells while maintaining the morphological features of the examined tissue. It was aimed to develop an automated LSC protocol to study cellular and nuclear anomalies and DNA damage events in human buccal mucosal cells. Since the buccal micronucleus cytome assay has been used to measure biomarkers of DNA damage (micronuclei and/or nuclear buds), cytokinesis defects (binucleated cells), proliferative potential (basal cell frequency), and/or cell death (condensed chromatin, karyorrhexis, and pyknotic and karyolytic cells), the following automated LSC protocol describes scoring criteria for these same parameters using an automated imaging LSC. In this automated LSC assay, cells derived from the buccal mucosa were harvested from the inside of patient's mouths using a small-headed toothbrush. The cells were washed to remove any debris and/or bacteria, and a single-cell suspension prepared and applied to a microscope slide using a cytocentrifuge. Cells were fixed and stained with Feulgen and Light Green stain allowing both chromatic and fluorescent analysis to be undertaken simultaneously with the use of an LSC.
引用
收藏
页码:321 / 339
页数:19
相关论文
共 50 条
  • [1] Laser scanning cytometry for automation of the micronucleus assay
    Darzynkiewicz, Zbigniew
    Smolewski, Piotr
    Holden, Elena
    Luther, Ed
    Henriksen, Mel
    Francois, Maxime
    Leifert, Wayne
    Fenech, Michael
    MUTAGENESIS, 2011, 26 (01) : 153 - 161
  • [2] Buccal micronucleus cytome assay
    Philip Thomas
    Nina Holland
    Claudia Bolognesi
    Micheline Kirsch-Volders
    Stefano Bonassi
    Errol Zeiger
    Siegfried Knasmueller
    Michael Fenech
    Nature Protocols, 2009, 4 : 825 - 837
  • [3] Buccal micronucleus cytome assay
    Thomas, Philip
    Holland, Nina
    Bolognesi, Claudia
    Kirsch-Volders, Micheline
    Bonassi, Stefano
    Zeiger, Errol
    Knasmueller, Siegfried
    Fenech, Michael
    NATURE PROTOCOLS, 2009, 4 (06) : 825 - 837
  • [4] Automation of mouse micronucleus genotoxicity assay by laser scanning cytometry
    Styles, JA
    Clark, H
    Festing, MFW
    Rew, DA
    CYTOMETRY, 2001, 44 (02): : 153 - 155
  • [5] Automation of the cytokinesis-block micronucleus cytome assay by laser scanning cytometry and its potential application in radiation biodosimetry
    Francois, Maxime
    Hochstenbach, Kevin
    Leifert, Wayne
    Fenech, Michael Felix
    BIOTECHNIQUES, 2014, 57 (06) : 309 - 312
  • [6] Buccal Micronucleus Cytome Assay in Sickle Cell Disease
    Naga, Mallika Bokka Sri Satya
    Gour, Shreya
    Nallagutta, Nalini
    Ealla, Kranti Kiran Reddy
    Velidandla, Surekha
    Manikya, Sangameshwar
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2016, 10 (06) : ZC62 - ZC64
  • [7] THE BEST SAMPLING TIME IN BUCCAL MICRONUCLEUS CYTOME ASSAY
    Nersesyan, Armen K.
    INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2012, 25 (03) : 310 - 313
  • [8] ADAPTING THE BUCCAL MICRONUCLEUS CYTOME ASSAY FOR USE IN DOGS
    Lentini, V
    Ferre, D. M.
    Gorla, N. B. M.
    BIOCELL, 2013, 37 (03) : A189 - A189
  • [9] Application of the Buccal Micronucleus Cytome Assay for Genotoxicity Detection in Dogs
    da Costa, Bruna Filipa Tavares
    Teixeira, Alexandra
    Prata, Joana C.
    Perez-Mongiovi, Daniel
    ANIMALS, 2025, 15 (03):
  • [10] RE: THE BEST SAMPLING TIME IN BUCCAL MICRONUCLEUS CYTOME ASSAY
    Cassini, Carina
    Calloni, Caroline
    Bortolini, Giovana
    Garcia, Solange Cristina
    Dornelles, Marco Aurelio
    Pegas Henriques, Joao Antonio
    Erdtmann, Bernardo
    Salvador, Mirian
    INTERNATIONAL JOURNAL OF OCCUPATIONAL MEDICINE AND ENVIRONMENTAL HEALTH, 2012, 25 (03) : 314 - 315