The trade-off between lateral resolution and depth of focus (DOF) severely limits the capability of endoscopic optical coherence tomography (OCT) for high-resolution deep-tissue imaging. To address this issue, we developed a novel miniature all-fiber axicon OCT probe by inserting a segment of gradient-index (GRIN) fiber between a piece of single-mode fiber (SMF) and an axicon polished from a no-core fiber. The GRIN lens served as a beam expander extending the probe DOF by 5.2 times while maintaining a high lateral resolution of 2 mu m. The DOF extension was experimentally verified by measuring the axial profile of the probe output beam and further by imaging multilayered polymer tapes and onion samples. The designed probe with a tight focus over a large DOF holds great potential in endoscopic OCT imaging of deep tissues at the cellular level. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:358 / 366
页数:9
相关论文
共 50 条
  • [1] All-fiber probe for optical coherence tomography with an extended depth of focus by a high-efficient fiber-based filter
    Qiu, Jianrong
    Shen, Yi
    Shangguan, Ziwei
    Bao, Wen
    Yang, Shanshan
    Li, Peng
    Ding, Zhihua
    OPTICS COMMUNICATIONS, 2018, 413 : 276 - 282
  • [2] Study on an all-fiber optical coherence tomography (OCT) probe
    Huang, Xiaoqian
    Tong, X. L.
    OPTICAL FIBER TECHNOLOGY, 2023, 79
  • [3] Extended focus optical coherence tomography with optical fiber based Bessel beam illumination
    Hu, D. J. J.
    Yan, L.
    Steinvurzel, P.
    Gora, M.
    Lu, W.
    Ramachandran, S.
    Wang, Y.
    Tearney, G. J.
    2013 CONFERENCE ON LASERS AND ELECTRO-OPTICS (CLEO), 2013,
  • [4] Performance comparison of the fiber axicon probe having extended Bessel focus with the cleaved fiber tip probe
    Gupta, P.
    Vairagi, K.
    Mondal, S.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XX, 2020, 11233
  • [5] All-fiber probe for optical coherence tomograpby
    Ryu, Seon Young
    Choi, Hae Young
    Na, Jihoon
    Choi, Woo June
    Lee, Byeong Ha
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XII, 2008, 6847
  • [6] Tapered structure based all-fiber probe for endoscopic optical coherence tomography
    Yan Xue-Guo
    Shen Yi
    Pan Cong
    Li Peng
    Ding Zhi-Hua
    ACTA PHYSICA SINICA, 2016, 65 (02)
  • [7] All-fiber negative axicon probe with a Bessel beam for cellular-level low coherence phase microscopy and refractive index measurement
    Gupta, Pooja
    Vairagi, Kaushal
    Mondal, Samir K.
    OPTICS LETTERS, 2022, 47 (03) : 497 - 500
  • [8] Reflective axicon based energy-efficient extended depth of focus quasi-Bessel beam probe for common-path optical coherence tomography
    Vairagi, Kaushal
    Gupta, Pooja
    Tiwari, Umesh Kumar
    Mondal, Samir K.
    APPLIED OPTICS, 2023, 62 (03) : 511 - 517
  • [9] Exceptional imaging performance optic coherence tomography miniature probe based on sizable fiber axicon
    Liu, Yin
    Zhang, Duanhong
    Li, Wenxin
    Zheng, Shicheng
    Hao, Qun
    Huang, Yong
    OPTICS AND LASERS IN ENGINEERING, 2025, 184
  • [10] Lens-free all-fiber probe with an optimized output beam for optical coherence tomography
    Ding, Zhihua
    Qiu, Jianrong
    Shen, Yi
    Chen, Zhiyan
    Bao, Wen
    OPTICS LETTERS, 2017, 42 (14) : 2814 - 2817