Diagnostic value of contrast-enhanced ultrasound and shear-wave elastography for breast lesions of sub-centimeter

被引:34
|
作者
Xiang, Li-Hua [1 ,2 ]
Yao, Ming-Hua [1 ,2 ]
Xu, Guang [1 ,2 ]
Pu, Huan [1 ,2 ]
Liu, Hui [1 ,2 ]
Fang, Yan [1 ,2 ]
Wu, Rong [1 ,2 ]
机构
[1] Tongji Univ, Shanghai Peoples Hosp 10, Dept Med Ultrasound, Shanghai, Peoples R China
[2] Tongji Univ, Sch Med, Ultrasound Res & Educ Inst, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Shear-wave elastography; contrast-enhanced ultrasound; lesion; breast; diagnosis; DATA SYSTEM; DIFFERENTIAL-DIAGNOSIS; CANCER; US; MAMMOGRAPHY; COMBINATION; CARCINOMA; ACCURACY; FEATURES; IMPROVES;
D O I
10.3233/CH-170250
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUD: Contrast-enhanced ultrasound (CEUS) and shear-wave elastography (SWE) are used for diagnostic purposes. OBJECTIVE: Investigate the diagnostic value of CEUS and SWE for breast lesions of sub-centimeter diameter. METHODS: Sixty-two patients (mean age: 49.3 +/- 12.1 years) with 66 lesions (mean diameter, 8.1 +/- 1.5 mm) were analyzed. Conventional ultrasound (US), CEUS and SWE were undertaken. Pathologic specimens were obtained through biopsy or surgery. Lesions were measured in kilopascals. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were analyzed. RESULTS: For conventional US, the sensitivity was 92.31%, specificity 28.30%, PPV 24.00%, NPV 93.75%, and accuracy 40.90%, whereas those for SWE were 61.54%, 98.11%, 88.89%, 91.23%, and 90.91% (p = 0.000) and CEUS were 92.31%, 60.38%, 36.37%, 96.97%, and 66.67% (p = 0.001), respectively. For SWE + CEUS, the sensitivity was 61.54%, specificity 100.00%, PPV 100.00%, NPV 91.38%, and accuracy 92.42% (p = 0.000). There was a significant difference between US and CEUS (p = 0.004), but not for SWE or SWE + CEUS (p = 0.568; p = 0.205). For SWE + CEUS, there was a significant difference with SWE alone and CEUS alone (p = 0.000; p = 0.008). Between SWE and CEUS, the difference was significant (p = 0.031). CONCLUSIONS: SWE and CEUS could help to differentiate between malignant and benign breast lesions <1 cm in diameter.
引用
收藏
页码:69 / 80
页数:12
相关论文
共 50 条
  • [1] Diagnostic value of contrast-enhanced ultrasound and shear-wave elastography for small breast nodules
    Shen, Yan
    He, Jie
    Liu, Miao
    Hu, Jiaojiao
    Wan, Yonglin
    Zhang, Tingting
    Ding, Jun
    Dong, Jiangnan
    Fu, Xiaohong
    [J]. PEERJ, 2024, 12
  • [2] Diagnostic value of contrast-enhanced ultrasound and shear-wave elastography for small breast nodules
    Shen, Yan
    He, Jie
    Liu, Miao
    Hu, Jiaojiao
    Wan, Yonglin
    Zhang, Tingting
    Ding, Jun
    Dong, Jiangnan
    Fu, Xiaohong
    [J]. PEERJ COMPUTER SCIENCE, 2024, 12
  • [3] Shear-wave elastography combined with contrast-enhanced ultrasound algorithm for noninvasive characterization of focal liver lesions
    Si-min Ruan
    Hui Huang
    Mei-qing Cheng
    Man-xia Lin
    Hang-tong Hu
    Yang Huang
    Ming-de Li
    Ming-de Lu
    Wei Wang
    [J]. La radiologia medica, 2023, 128 : 6 - 15
  • [4] Shear-wave elastography combined with contrast-enhanced ultrasound algorithm for noninvasive characterization of focal liver lesions
    Ruan, Si-min
    Huang, Hui
    Cheng, Mei-qing
    Lin, Man-xia
    Hu, Hang-tong
    Huang, Yang
    Li, Ming-de
    Lu, Ming-de
    Wang, Wei
    [J]. RADIOLOGIA MEDICA, 2023, 128 (01): : 6 - 15
  • [5] Diagnostic accuracy of contrast-enhanced ultrasound synchronized with shear wave elastography in the differential diagnosis of benign and malignant breast lesions: a diagnostic test
    He, Huiling
    Wu, Xiaojin
    Jiang, Meijuan
    Xu, Zhikang
    Zhang, Xuanxuan
    Pan, Jianlian
    Fu, Xinyu
    Luo, Yunkai
    Chen, Jian
    [J]. GLAND SURGERY, 2023, : 54 - 66
  • [6] LOGISTIC REGRESSION ANALYSIS OF CONTRAST-ENHANCED ULTRASOUND AND CONVENTIONAL ULTRASOUND CHARACTERISTICS OF SUB-CENTIMETER THYROID NODULES
    Zhao, Rui-Na
    Zhang, Bo
    Yang, Xiao
    Jiang, Yu-Xin
    Lai, Xing-Jian
    Zhang, Xiao-Yan
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (12): : 3102 - 3108
  • [7] Effect of contrast-enhanced ultrasound (CEUS) on liver stiffness measurements obtained by transient and shear-wave elastography
    Kayali, Stefano
    Pasta, Andrea
    Pellicano, Rinaldo
    Fagoonee, Sharmila
    Giuliana, Elisabetta
    Facchini, Chiara
    Pili, Simona
    Buccilli, Silvia
    Labanca, Sara
    Borro, Paolo
    [J]. PANMINERVA MEDICA, 2022, 64 (04) : 479 - 484
  • [8] The value of contrast-enhanced ultrasound versus shear wave elastography in differentiating benign and malignant superficial lymph node lesions
    Cai, Huahai
    Liu, Shuyu
    [J]. AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2021, 13 (10): : 11625 - 11631
  • [9] A diagnostic analysis of ultrasound elastography and contrast-enhanced ultrasound in focal liver lesions
    Wang, Yongqing
    Lu, Pingping
    Cui, Yuanping
    Zhang, Xiaohong
    [J]. INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 12 (10): : 12331 - 12339
  • [10] Evaluating diagnostic significance: The utilization of elastography and contrast-enhanced ultrasound for differential diagnosis in breast lesions
    Wen, Peng
    Liu, Lei
    Pan, Lili
    Li, Xiukun
    [J]. CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2024, 88 (01) : 81 - 95