Corrosion inhibition of hydrazine on carbon steel in water solutions with different pH adjusted by ammonia

被引:0
|
作者
Yu, Huaqiang [1 ]
Ge, Honghua [1 ]
Zhang, Jialin [1 ]
Li, Ji [1 ]
Liu, Jiaman [1 ]
Zhao, Yuzeng [1 ]
机构
[1] Shanghai Univ Elect Power, Shanghai Engn Res Ctr Energy Saving Heat Exchange, Shanghai Key Lab Mat Protect & Adv Mat Elect Powe, Shanghai 200090, Peoples R China
基金
上海市自然科学基金;
关键词
ammonia; carbon steel; corrosion; hydrazine; shutdown protection; HIGH-TEMPERATURE CORROSION; HYDROGEN COINJECTION; STRUCTURAL-MATERIALS; BEHAVIOR; CONDUCTIVITY; MECHANISM; REACTORS; CRACKING;
D O I
10.1515/corrrev-2022-0029
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The ammonia-hydrazine shutdown protection method is widely used in thermal power plants in China because of its good protective performance. However, the toxicity and safety of hydrazine have restricted its use in many power plants, and it is necessary to improve the shutdown protection techniques. In this paper, electrochemical impedance spectroscopy and potentiodynamic polarization curves were used to study the effect of hydrazine in water solutions of different pH values, adjusted with ammonia on the corrosion behavior of carbon steel. It was found that in the water solution without hydrazine, the corrosion resistance of a carbon steel electrode increased with raising the pH. When the pH value of water increased to 10.5, the impedance value of the carbon steel increased significantly, the corrosion current density decreased from 26.06 mu A center dot cm(-2) at pH 10.0 to 2.36 mu A center dot cm(-2), and the steel surface was passivated. Hydrazine had different effects on the electrochemical corrosion behavior of carbon steel in water solutions with various pH. When the pH of water was not higher than 10.0, hydrazine had a good corrosion inhibition effect on carbon steel. When the pH of water was not lower than 10.5, the addition of hydrazine inhibited the passivation of carbon steel and promoted the corrosion. The adsorption and substitutional oxidation of hydrazine in the anode region of carbon steel surface should be the reasons for the above phenomenon.
引用
收藏
页码:587 / 596
页数:10
相关论文
共 50 条