Design and Fabrication of Liquid Pressure Sensor Using FBG Sensor Through Seesaw Hinge Mechanism

被引:3
|
作者
Vaddadi, Venkata Satya Chidambara Swamy [1 ]
Parne, Saidi Reddy [1 ]
Vijeesh, V. P. [1 ]
Gandi, Suman [1 ]
Panda, Saran Srihari Sripada [1 ]
Cenkeramaddi, Linga Reddy [2 ]
机构
[1] Natl Inst Technol Goa, Dept Appl Sci, Ponda 403401, India
[2] Univ Agder, Dept Informat & Commun Technol, Autonomous & Cyber Phys Syst ACPS Res Grp, N-4879 Grimstad, Norway
来源
IEEE PHOTONICS JOURNAL | 2022年 / 14卷 / 05期
关键词
3-D printing; Acrylonitrile-Butadlene-Styrene (ABS); diaphragm; Fiber Bragg Grating (FBG) sensor; seesaw mechanism; BRAGG GRATING SENSOR; TEMPERATURE-MEASUREMENT; WATER-LEVEL;
D O I
10.1109/JPHOT.2022.3210146
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pressure sensors are used in various industrial applications assisting in preventing unintended disasters. This paper presents the design and fabrication of a novel Seesaw device incorporating a diaphragm and Fiber Bragg Grating (FBG) sensor to measure the pressure of liquids. The designed sensor has been tested in a static water column. The proposed design enables the user to easily make and modify the diaphragm based on the required pressure range without interfering with the FBG sensor. The developed pressure sensor produces improved accuracy and sensitivity to applied liquid pressure in both low and high-pressure ranges without requiring sophisticated sensor construction. A finite element analysis has been performed on the diaphragm and on the entire structure at 10 bar pressure. The deformation of the diaphragm is comparable to theoretical deformation levels. A copper diaphragm with a thickness of 0.25 mm is used in the experiments. All experiments are performed in the elastic region of the diaphragm. The sensor's sensitivity as 19.244 nm/MPa with the linearity of 99.64 % is obtained based on the experiments. Also, the proposed sensor's performance is compared with recently reported pressure sensors.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Design, Fabrication and Testing of a 3D Printed FBG Pressure Sensor
    Hong, Chengyu
    Zhang, Yifan
    Borana, Lalit
    IEEE ACCESS, 2019, 7 : 38577 - 38583
  • [2] Design and realization of spoke FBG pressure sensor
    Institute of Modern Optics, Nankai University, Tianjin 300071, China
    Guangzi Xuebao, 2006, 1 (105-108):
  • [3] Sensing of hydrostatic pressure using FBG sensor for liquid level measurement
    Sengupta, D.
    Shankar, M. Sai
    Reddy, P. Saidi
    Prasad, R. L. N. Sai
    Srimannarayana, K.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2012, 54 (07) : 1679 - 1683
  • [4] FBG displacement sensor with hyperbolic flexible hinge structure
    Shi, Yan
    Wang, Chenxu
    Cai, Jianxian
    Gao, Zhitao
    Zhang, Yuzi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (12)
  • [5] Development of FBG-based liquid pressure sensor for engineering
    Lan, Chunguang
    Liu, Hang
    Tian, Yuji
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2013, 34 (09): : 2153 - 2160
  • [6] An FBG based hydrostatic pressure sensor for liquid level measurements
    Sengupta, D.
    Shankar, M. Sai
    Reddy, P. Saidi
    Prasad, R. L. N. Sai
    Srimannarayana, K.
    MICRO-STRUCTURED AND SPECIALTY OPTICAL FIBRES, 2012, 8426
  • [7] A simple underground liquid level sensor using FBG
    Sengupta, D.
    Shankar, M. Sai
    Reddy, P. Saidi
    Prasad, R. L. N. Sai
    Srimannarayana, K.
    OPTICS: PHENOMENA, MATERIALS, DEVICES, AND CHARACTERIZATION: OPTICS 2011: INTERNATIONAL CONFERENCE ON LIGHT, 2011, 1391
  • [8] A High Sensitivity FBG Strain Sensor Based on Flexible Hinge
    Liu, Mingyao
    Wang, Wenzhi
    Song, Han
    Zhou, Shiguang
    Zhou, Weijian
    SENSORS, 2019, 19 (08)
  • [9] Design, fabrication and test of a VME pressure sensor
    Xia, SH
    Chen, SF
    Liu, J
    CHINESE JOURNAL OF ELECTRONICS, 2003, 12 (01): : 71 - 74
  • [10] THE DESIGN AND FABRICATION OF IMPLANTED INTRACRANIAL PRESSURE SENSOR
    Tian Bian
    Zhao Yulong
    Jiang Zhuangde
    BIODEVICES 2009: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2009, : 296 - 299