Study on improving levitation stability from high frequency vibration for the application of a seismic isolation device

被引:1
|
作者
Jang, H. K. [1 ]
Song, D. [1 ]
Kim, S. B. [1 ]
Han, S. C. [2 ]
Lee, J. P. [2 ]
Kim, S. J. [3 ]
Sung, T. H. [1 ]
机构
[1] Hanyang Univ, Seoul 133791, South Korea
[2] Korea Elect Power Res Inst, Taejon 305760, South Korea
[3] Korea Inst Sci & Technol, Seoul 136791, South Korea
来源
关键词
Superconductor bulk; Permanent magnet; Copper plate; Stabilized levitation; Eddy current;
D O I
10.1016/j.physc.2011.05.224
中图分类号
O59 [应用物理学];
学科分类号
摘要
The stability of superconductor levitation is depending on the pinning force. However, when an external force such as the earthquake with a high magnitude higher than the pinning force is exerted, the levitated permanent magnet (PM) can become unstable and destroyed. In order to improve the stability of the levitation, a copper plate was inserted in between the HTS (high temperature superconductor) bulk and the PM. And the more stabilized levitation can be achieved by applying eddy current that is caused by PM and the copper plate. In this study, various arrangements of PM, the thickness of copper plate, the area and gap length between PM and the copper plate were carried out. The eddy current was greater in the arrangement where polarity was changed with parallel to a moving shaker than the arrangement where polarity was not changed. And also, the eddy current became greater as the gap length between the PM and copper plate decreased. The highest value of the eddy current was measured at a copper plate thickness of 5 mm and a size of 80 mm x 80 mm. From the eddy current experiments, a copper plate (80 mm x 80 mm x 5 mm) inserted between the 7 mm gap length of the HIS bulk and the PM was resulted in a higher stiffness value of 65% compared to no copper plate stiffness value. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:1497 / 1500
页数:4
相关论文
共 50 条
  • [1] Vibration Transmission Characteristics Against Vertical Vibration in Magnetic Levitation Type HTS Seismic/Vibration Isolation Device
    Tsuda, Makoto
    Tamashiro, Keisuke
    Sasaki, Shuhei
    Yagai, Tsuyoshi
    Hamajima, Takataro
    Yamada, Takashi
    Yasui, Kenji
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 2249 - 2252
  • [2] Dependence of horizontal vibration characteristics on load weight distribution in magnetic levitation type seismic isolation device
    Tsuda, M.
    Kawasaki, T.
    Yagai, T.
    Hamajima, T.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2008, 18 (02) : 832 - 835
  • [3] Suitable Shape and Arrangement of HTS Bulk and Permanent Magnet for Improving Levitation Force in a Magnetic Levitation Type Superconducting Seismic Isolation Device
    Sasaki, S.
    Shimada, K.
    Yagai, T.
    Tsuda, M.
    Hamajima, T.
    Kawai, N.
    Yasui, K.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2010, 20 (03) : 985 - 988
  • [4] Vibration characteristics in magnetic levitation type seismic isolation device composed of multiple HTS bulks and permanent magnets
    Tsuda, M. ]
    Kojima, T.
    Yagai, T.
    Hamajima, T.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 2059 - 2062
  • [5] Stationary levitation and vibration transmission characteristic in a superconducting seismic isolation device with a permanent magnet system and a copper plate
    Sasaki, S.
    Shimada, K.
    Yagai, T.
    Tsuda, M.
    Hamajima, T.
    Kawai, N.
    Yasui, K.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2010, 470 (20): : 1791 - 1794
  • [6] Development of seismic isolation device to suppress infinitesimal vibration
    Yachiune K.
    Inai S.
    Yamamoto T.
    Tokuno M.
    Kobayashi M.
    1600, Architectural Institute of Japan (27): : 136 - 141
  • [7] Choice of Parameters and Stability of Nonlinear Vibration Isolation Device
    Mustafina, R. M.
    Plotnikov, I. A.
    Plotnikova, I. V.
    Tchaikovskaya, O. N.
    III ALL-RUSSIAN SCIENTIFIC AND PRACTICAL CONFERENCE ON INNOVATIONS IN NON-DESTRUCTIVE TESTING (SIBTEST 2015), 2016, 671
  • [8] HIGH-FREQUENCY VIBRATION ISOLATION
    UNGAR, EE
    DIETRICH, CW
    JOURNAL OF SOUND AND VIBRATION, 1966, 4 (02) : 224 - &
  • [9] Performance Experimental Study and Vibration Isolation Parameter Analysis on Vertical Seismic Isolation Device with Hydraulic Jack and Accumulator
    Lu, Liang
    Wang, Lei
    Xia, Wanqiu
    Li, Yuanqing
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 51 (11): : 1 - 11
  • [10] Improvement of Levitation Force Characteristics in Magnetic Levitation Type Seismic Isolation Device Composed of HTS Bulk and Permanent Magnet
    Tsuda, M.
    Kawasaki, T.
    Yagai, T.
    Hamajima, T.
    8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97