Proposed Use of Monte Carlo Simulated Images to Evaluate the Accuracy of Measurements on X-Ray Computed Tomography

被引:1
|
作者
Kowaluk, Tomasz [1 ]
Maciak, Maciej [1 ]
Wozniak, Adam [1 ]
Tulik, Piotr [1 ]
Golnik, Natalia [1 ]
机构
[1] Warsaw Univ Technol, Fac Mechatron, Inst Metrol & Biomed Engn, Sw A Boboli 8 St, PL-02525 Warsaw, Poland
来源
MEASUREMENT SCIENCE REVIEW | 2018年 / 18卷 / 06期
关键词
Monte Carlo Methods; X-ray computed tomography; accuracy of measurements; threshold values;
D O I
10.1515/msr-2018-0034
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
X-ray computed tomography (CT) is increasingly recognized as a promising measuring technique for dimensional metrology. Various methods are being developed to improve measurement accuracy. Tests of new methods for such applications include accuracy evaluation with the use of calibrated workpieces; however, the internal algorithms of image acquisition and data processing might influence the experimental error, and then also the comparison of methods at different CTs. The accuracy of the results of tomographic measurements is influenced by many factors, one of which is the setting of the threshold value. The article presents the results of an attempt to use Monte Carlo simulated images to estimate deviations to determine threshold values to improve measurement accuracy and additionally, to estimate the impact of data processing. The differences of the results obtained from the simulated images were up to 4 % larger than those from tomographic images. It was caused by degradation of the image contrast by scattered radiation.
引用
收藏
页码:251 / 255
页数:5
相关论文
共 50 条
  • [1] Computed tomography x-ray characterization: A Monte Carlo study
    Campos, Luciana Tourinho
    de Jesus, Fillipe Machado
    de Souza Goncalves, Elicardo Alves
    Goncalves Magalhaes, Luis Alexandre
    RADIATION PHYSICS AND CHEMISTRY, 2020, 167 (167)
  • [2] Monte Carlo simulation of a computed tomography x-ray tube
    Bazalova, Magdalena
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5945 - 5955
  • [3] A Monte Carlo simulation of scattering reduction in spectral X-ray computed tomography
    Busi, Matteo
    Olsen, Ulrik L.
    Knudsen, Erik B.
    Frisvad, Jeppe R.
    Kehres, Jan
    Christensen, Erik D.
    Khalil, Mohamad
    Haldrup, Kristoffer
    ADVANCES IN COMPUTATIONAL METHODS FOR X-RAY OPTICS IV, 2017, 10388
  • [4] Mammography X-ray spectra simulated with Monte Carlo
    Vega-Carrillo, H. R.
    Gonzalez, J. Ramirez
    Manzanares-Acuna, E.
    Hernandez-Davila, V. M.
    Villasana, R. Hernandez
    Mercado, G. A.
    MEDICAL PHYSICS, 2008, 1032 : 208 - 211
  • [5] Off-axis x-ray spectra: A comparison of Monte Carlo simulated and computed x-ray spectra with measured spectra
    Bhat, M
    Pattison, J
    Bibbo, G
    Caon, M
    MEDICAL PHYSICS, 1999, 26 (02) : 303 - 309
  • [6] Use of Monte Carlo method to evaluate the response of direct conversion X-ray detectors
    Gui Jian-Bao
    Guo Jin-Chuan
    Yang Qin-Lao
    Niu Han-Ben
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2007, 31 (10): : 933 - 937
  • [7] Monte Carlo simulations of meso-scale dynamic compressive behavior of concrete based on X-ray computed tomography images
    Huang, Y. J.
    Yang, Z. J.
    Chen, X. W.
    Liu, G. H.
    INTERNATIONAL JOURNAL OF IMPACT ENGINEERING, 2016, 97 : 102 - 115
  • [8] Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes
    Hayati H.
    Mesbahi A.
    Nazarpoor M.
    Radiological Physics and Technology, 2016, 9 (1) : 37 - 43
  • [9] Dimensional accuracy in X-ray computed tomography imaging
    Neel, ST
    Gibson, R
    Daniels, CR
    Klosterman, EL
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 411 - 418
  • [10] Porosity measurements by X-ray computed tomography: Accuracy evaluation using a calibrated object
    Hermanek, Petr
    Carmignato, Simone
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2017, 49 : 377 - 387