Polymer type effect on PLGA-based microparticles preparation by solvent evaporation method with single emulsion system using focussed beam reflectance measurement

被引:4
|
作者
Muhaimin, Muhaimin [1 ]
Chaerunisaa, Anis Yohana [1 ]
Bodmeier, Roland [2 ]
机构
[1] Univ Padjadjaran, Fac Pharm, Jatinangor, Indonesia
[2] Free Univ Berlin, Coll Pharm, Berlin, Germany
关键词
PLGA; solvent; FBRM; microparticles; solvent evaporation method; chord length distribution; chord count; square weighted mean chord length; PARTICLE VIDEO MICROSCOPE; SIZE DISTRIBUTIONS; FBRM; MICROSPHERES; ETHYLCELLULOSE; SOLUBILITY; DROPLET; POLY(EPSILON-CAPROLACTONE); MICROENCAPSULATION; ENCAPSULATION;
D O I
10.1080/02652048.2022.2116120
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
Aim This study aimed to investigate the effect of polymer type on solidification rate of PLGA polymeric microparticles and particle size/distribution of the emulsion droplets/hardened PLGA polymeric microparticles during solvent evaporation process using FBRM (Focussed Beam Reflectance Measurement). Methods PLGA polymeric microparticles were prepared by an O/W solvent evaporation method using various PLGA polymers, including PLGA Resomer (R) RG503H, RG502H and RG752H. The particle size mean, chord length distribution (CLD), and chord count of the emulsion droplets/hardened microparticles were monitored by FBRM. The morphology of polymeric microparticles were characterised by optical microscopy and scanning electron microscopy (SEM). Results The transformation of the emulsion droplets into solid microparticles occurred within the first 30 (+/- 1.04), 34 (+/- 1.15) and 37 (+/- 0.82) min and square weighted mean chord lengths are 64.08 (+/- 3.18), 52.36 (+/- 5.27) and 42.18 (+/- 4.61) mu m when PLGA Resomer (R) RG503H, RG502H and RG752H were used respectively. Larger square weighted mean chord length of PLGA polymeric microparticles gave lower chord counts. PLGA RG752H microparticles gave smallest square weighted mean chord length and the chord counts was the highest. The CLDs measured by FBRM showed that a larger particle size mean gave longer CLD and a lower peak of particle number. SEM data revealed that the morphology of microparticles was influenced by type and physical properties of polymer. Conclusions FBRM can be employed for online monitoring of the shift in the microparticle CLD and detect transformation of the emulsion droplets into solid microparticles during the solvent evaporation process. The microparticle CLD and transformation process were strongly influenced by polymer type.
引用
收藏
页码:512 / 521
页数:10
相关论文
共 8 条