Evaluation of hydronic forced-air and radiant slab heating and cooling systems

被引:0
|
作者
Baskin, E [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
A contemporary house located in California has a unique HVAC system featuring radiant floor heating and cooling, forced-air hydronic heating and cooling, and a system that ventilates the house at night to reduce air conditioner energy use by pre-cooling building mass. The purpose of this study was to compare the energy consumption and electrical power demand characteristics of the various heating and cooling operating modes. Cooling season testing involved three different operating modes during similar weather conditions and comparable indoor comfort conditions. Heating testing involved operation in two test modes: hydronic radiant floor heating and hydronic forced-air heating, both by heating water with natural gas. Energy performance results reveal that slab pre-cooling caused some of the energy demand to shift from primarily in the afternoon. Coupling slab pre-cooling with nighttime ventilation air significantly shifted the energy demand load from primarily in the afternoon to late night with the load coming mainly from the fan. Also, during comparable outside conditions, there were appreciable energy differences among cooling modes and no identifiable energy advantage was noticed during the heating mode.
引用
收藏
页码:525 / 534
页数:10
相关论文
共 50 条
  • [1] STUDY ON FORCED-AIR FORCED-AIR COOLING FOR DP WIRE ROD
    HANADA, Y
    [J]. TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1985, 71 : 1131 - 1131
  • [2] PULSE COMBUSTION FORCED-AIR HEATING
    STEPHENS, RL
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1983, 19 (04) : 498 - 501
  • [3] Analysis of Integrated Radiant Slab Heating and Cooling Systems for Residential Buildings
    Park, Benjamin
    Krarti, Moncef
    [J]. JOURNAL OF ARCHITECTURAL ENGINEERING, 2016, 22 (01)
  • [4] Comparison of the performance of a forced-air and a radiant floor residential heating system connected to solar collectors
    Haddad, Kammel
    Purdy, Julia
    Laouadi, Aziz
    [J]. JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2007, 129 (04): : 465 - 472
  • [5] Development of an evaluation strategy of hydronic balancing valves for radiant floor heating systems
    Rhee, K. N.
    Shin, M. S.
    Yeo, Myoung-Souk
    Kim, K. W.
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2015, 36 (04): : 422 - 438
  • [6] Numerical modeling of forced-air cooling of palletized apple: Integral evaluation of cooling efficiency
    Han, Jia-Wei
    Zhao, Chun-Jiang
    Qian, Jian-Ping
    Ruiz-Garcia, Luis
    Zhang, Xiang
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2018, 89 : 131 - 141
  • [7] FORCED-AIR COOLING OF PALLETIZED FRESH FRUIT
    PARSONS, RA
    MITCHELL, FG
    MAYER, G
    [J]. TRANSACTIONS OF THE ASAE, 1972, 15 (04): : 729 - &
  • [8] Comparison of forced-air warming and resistive heating
    Perl, T.
    Floether, I.
    Weyland, W.
    Quintel, M.
    Braeuer, A.
    [J]. MINERVA ANESTESIOLOGICA, 2008, 74 (12) : 687 - 690
  • [9] FORCED-AIR COOLING OF PALLETIZED FRESH FRUIT
    PARSONS, RA
    MITCHELL, FG
    MAYER, G
    [J]. AGRICULTURAL ENGINEERING, 1970, 51 (10): : 571 - &
  • [10] FORCED-AIR COOLING OF BELL PEPPERS IN BULK
    GAFFNEY, JJ