Online nonlinear ultrasound imaging of crack closure during thermal fatigue loading

被引:4
|
作者
Koskinen, Tuomas [1 ]
Kuutti, Juha [1 ]
Virkkunen, Iikka [2 ]
Rinta-aho, Jari [1 ]
机构
[1] VTT Tech Res Ctr Finland, Espoo, Finland
[2] Aalto Univ, Espoo, Finland
关键词
Thermal fatigue; Crack closure; Ultrasound; Fundamental wave amplitude difference; Nonlinear ultrasound; ACOUSTIC NONLINEARITY; CLOSED CRACKS; REFLECTION;
D O I
10.1016/j.ndteint.2021.102510
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A thermal fatigue surface crack (6 mm deep x 23 mm wide) in a thick austenitic stainless steel plate is opened and closed with thermal heating and cooling cycles. This closing and opening of the crack is recorded with using fundamental wave amplitude difference (FAD) technique with 5 MHz 64 element phased array probe. In addition, the contact pressure and crack opening state at different time intervals were estimated using finite element (FE) simulation. In combination with the nonlinear output from the FAD and FE simulation gave insight at which level the contact pressure or the distance between crack faces prevents the contact acoustic nonlinearity (CAN) from happening. Predictably, no clear nonlinear response was recorded at crack face locations experiencing high contact pressure and on the locations where the crack could be considered fully open, as predicted by the FE simulation. Therefore, the FAD technique can be utilized within the constraints quantified in the paper.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Fatigue crack closure analysis using nonlinear ultrasound
    Akino, M
    Mihara, T
    Yamanaka, K
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 23A AND 23B, 2004, 23 : 1256 - 1263
  • [2] On-line fatigue crack closure determination using nonlinear ultrasound testing
    Jia J.
    Tao L.
    Hu H.
    Hu Y.
    Lyu W.
    Tao, Limin (tlm1964@sina.com), 2018, National University of Defense Technology (40): : 97 - 102
  • [3] Influence of the online closure loading on the eddy current testing signals of closed fatigue crack
    Cai, Wenlu
    Xie, Zheng
    Xie, Shejuan
    Pei, Cuixiang
    Li, Yong
    Chen, Zhenmao
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2016, 52 (1-2) : 297 - 306
  • [4] REVIEW ON CRACK CLOSURE FOR CONSTANT AMPLITUDE LOADING IN FATIGUE
    KUMAR, R
    ENGINEERING FRACTURE MECHANICS, 1992, 42 (02) : 389 - 400
  • [5] CRACK CLOSURE BEHAVIOUR AND ITS EFFECT ON FATIGUE CRACK PROPAGATION UNDER ELASTOPLASTIC FATIGUE LOADING
    Yamazaki, Yasuhiro
    Azuma, Kisaburo
    7TH INTERNATIONAL CONFERENCE INTEGRITY-RELIABILITY-FAILURE (IRF2020), 2020, : 263 - 270
  • [6] The effects of the loading conditions on crack closure phenomenon in fatigue crack propagation (FCP)
    Wang, H
    Decoopman, X
    Imad, A
    Nait-Abdelaziz, M
    Mesmacque, G
    FATIGUE '99: PROCEEDINGS OF THE SEVENTH INTERNATIONAL FATIGUE CONGRESS, VOLS 1-4, 1999, : 533 - 538
  • [7] Fatigue crack growth and closure behaviour under multiaxial loading
    Chermahini, R. G.
    Jabbari, M.
    FATIGUE 2010, 2010, 2 (01): : 2021 - 2026
  • [8] NOTE ON CLOSURE DURING FATIGUE CRACK GROWTH
    MCCARTNEY, LN
    INTERNATIONAL JOURNAL OF FRACTURE, 1979, 15 (01) : R21 - R24
  • [9] FATIGUE CRACK-PROPAGATION AND CRACK CLOSURE BEHAVIOR UNDER VARYING LOADING CONDITIONS
    KIKUKAWA, M
    JONO, M
    TANAKA, KI
    KONDO, Y
    INTERNATIONAL JOURNAL OF FRACTURE, 1977, 13 (05) : 702 - 704
  • [10] Effect of closure of the tip of a fatigue crack on the asymmetry of loading cycles and on the thresholds of crack resistance
    Pinyak I.S.
    Strength of Materials, 2000, 32 (06) : 564 - 570