Impact of transrenal aortic endograft placement on endovascular graft repair of abdominal aortic aneurysms

被引:110
|
作者
Marin, ML
Parsons, RE
Hollier, LH
Mitty, HA
Ahn, J
Parsons, RE
Temudom, T
D'Ayala, M
McLaughlin, M
DePalo, L
Kahn, R
机构
[1] Mt Sinai Sch Med, Dept Surg, New York, NY USA
[2] Mt Sinai Sch Med, Dept Radiol, New York, NY USA
[3] Mt Sinai Sch Med, Dept Med, New York, NY USA
[4] Mt Sinai Sch Med, Dept Anesthesiol, New York, NY USA
关键词
D O I
10.1016/S0741-5214(98)70088-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Successful endovascular repair of an abdominal aortic aneurysm (AAA) requires the creation of a hemostatic seal between the endograft and the underlying aortic wall. A short infrarenal aortic neck may be responsible for incomplete aneurysm exclusion and procedural failure. Sixteen patients who had an endograft positioned completely below the lowest renal artery and 37 patients in whom a porous portion of an endograft attachment system was deliberately placed across the renal arteries were studied to identify if endograft positioning could impact on the occurrence of incomplete aneurysm exclusion. Methods: Fifty-three patients underwent aortic grafting constructed from a Palmaz balloon expandable stent and an expandable polytetrafluoroethylene (ePTFE) graft implanted in an aorto-ilio-femoral, femoral-femoral configuration. Arteriography, duplex ultrasonography and spiral CT scans were performed in each patient before and after endografting to evaluate for technical success, the presence of endoleaks, and renal artery perfusion. Results: There was no statistically significant difference in patient demography, AAA.size, or aortic neck length or diameter between patients who had their endografts placed below or across the renal arteries. However, significantly more proximal aortic endoleaks occurred in those patients with infrarenal endografts (P less than or equal to.05). Median serum creatinine level before and after endografting was not significantly different between the 2 patient subgroups, with the exception of 2 patients who had inadvertent coverage of a single renal orifice by the endograft. Median blood pressure and the requirement for antihypertensive therapy remained the same after transrenal aortic stent grafting. Significant renal artery compromise did not occur after appropriately positioned transrenal stents as shown by means of angiography, CT scanning, and duplex ultrasound scan. Mean follow-np time was 10.3 months (range, 3 to 18 months). Patients who had significant renal artery stenosis (greater than or equal to 50%) before aortic endografting did not show progression of renal artery stenosis after trans-renal endografting. Two patients with transrenal aortic stent grafts had inadvertent coverage of 1 renal artery by the endograft because of device malpositioning, which resulted in nondialysis dependent renal insufficiency. In addition, evidence of segmental renal artery infarction (<20% of the kidney), which did not result in an apparent change in renal function, was Shown by means of follow-up CT scans in 2 patients with transrenal endografts. Conclusion: Transrenal aortic endograft fixation using a balloon expandable device in patients with AAAs can result in a significant reduction in the risk of proximal endoleaks. Absolute attention to precise device positioning, coupled with the use of detailed imaging techniques, should reduce the risk of inadvertent renal artery occlusion from malpositioning. Long-term follow-up is essential to determine if there will be late sequelae of transrenal fixation of endografts, which could adversely effect renal perfusion.
引用
收藏
页码:638 / 646
页数:9
相关论文
共 50 条
  • [1] Endovascular Repair of Ruptured Abdominal Aortic Aneurysms Using the Endurant™ Endograft
    Nana, Petroula
    Volakakis, George
    Spanos, Konstantinos
    Kouvelos, George
    Bareka, Metaxia
    Arnaoutoglou, Eleni
    Giannoukas, Athanasios
    Matsagkas, Miltiadis
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (17)
  • [2] Endograft Conformability in Fenestrated Endovascular Aneurysm Repair for Complex Abdominal Aortic Aneurysms
    de Niet, Arne
    Donselaar, Esme J.
    Holewijn, Suzanne
    Tielliu, Ignace F. J.
    Lardenoije, Jan Willem H. P.
    Zeebregts, Clark J.
    Reijnen, Michel M. P. J.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2020, 27 (05) : 848 - 856
  • [3] A new generation endovascular graft for repair of abdominal aortic aneurysms
    Gorin, DR
    Arbid, EJ
    DAgostino, R
    Yucel, EK
    Solovay, KS
    LaMorte, WW
    Quist, WC
    Mulligan, N
    Menzoian, JO
    [J]. AMERICAN JOURNAL OF SURGERY, 1997, 173 (03): : 159 - 164
  • [4] Stent graft types for endovascular repair of abdominal aortic aneurysms
    Duffy, James M. N.
    Rolph, Rachel
    Waltham, Matthew
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2015, (09):
  • [5] Impact of endovascular repair for abdominal aortic aneurysms in octogenarians
    Lobato, AC
    Rodriguez-Lopez, J
    Malik, A
    Vranic, M
    Vaughn, PL
    Douglas, M
    Diethrich, EB
    [J]. ANNALS OF VASCULAR SURGERY, 2001, 15 (05) : 525 - 532
  • [6] Stent graft types for endovascular repair of abdominal aortic aneurysms
    Duffy, James M. N.
    Rolph, Rachel
    Clough, Rachel E.
    Modarai, Bijan
    Taylor, Peter
    Waltham, Matthew
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (03):
  • [7] Endovascular repair of abdominal aortic aneurysms
    Arnaoutakis, Dean J.
    Zammert, Martin
    Karthikesalingam, Alan
    Belkin, Michael
    [J]. BEST PRACTICE & RESEARCH-CLINICAL ANAESTHESIOLOGY, 2016, 30 (03) : 331 - 340
  • [8] Endovascular repair of abdominal aortic aneurysms
    Fan, CM
    Santilli, JG
    [J]. SEMINARS IN ROENTGENOLOGY, 2002, 37 (04) : 282 - 292
  • [9] Endovascular repair for abdominal aortic aneurysms
    Debono, Samuel
    Nash, Jennifer
    Tambyraja, Andrew L.
    Newby, David E.
    Forsythe, Rachael O.
    [J]. HEART, 2021, 107 (22) : 1783 - 1789
  • [10] Endovascular repair of abdominal aortic aneurysms
    Bell, PRF
    [J]. VASCULAR MEDICINE, 2002, 7 (04) : 253 - 255