Sparse Array Ultrasonic Lamb Wave TDTE Imaging Method

被引:9
|
作者
Yao-Cheng [1 ]
Zhu, Wen-Fa [1 ,2 ]
Chai, Xiao-Dong [1 ]
Sun, Liu-Jia [1 ]
Wei-Lv [3 ]
Fan, Guo-Peng [1 ]
Shu-Bin Zheng [1 ]
Hui-Zhang [1 ]
机构
[1] Shanghai Univ Engn Sci, Sch Urban Railway Transportat, Shanghai 201620, Peoples R China
[2] East China Univ Sci & Technol, Sch Mech & Power Engn, Shanghai 200237, Peoples R China
[3] China Railway Sci & Ind Grp Co Ltd, Wuhan 430066, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Imaging; Sensor arrays; Apertures; Sensors; Acoustics; Image sensors; Cost function; Asymmetric defect; lamb wave; sparse array; TDTE; ultrasonic imaging; TOPOLOGICAL SENSITIVITY; INVERSE SCATTERING; IDENTIFICATION; TOMOGRAPHY; EQUATION;
D O I
10.1109/JSEN.2021.3100615
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The current Lamb wave topology imaging methods are limited to the ideal model of through-hole defects, ignoring the influence of mode coupling. However, blind hole defects, such as structural plate corrosion and cracks, are the most likely defects in practical applications, and Lamb waves are bound to appear mode-coupled at these defects. The use of the full matrix data calculations of the direct and concomitant sound fields is time-consuming and limits the industrial application of the ultrasonic Lamb wave time-domain topological energy (TDTE) imaging method. A TDTE imaging method of a sparse ultrasonic Lamb wave is proposed in this paper to solve the aforementioned two problems. The sparse array is designed based on a genetic algorithm, then the direct sound field and the accompanying sound field are calculated using the sparse array data. The mode conversion of the Lamb wave is considered when calculating the accompanying sound field, and then the accompanying sound field is reversed in time so that the direct sound field and the accompanying sound field are adaptively focused at the defect. The influence of Lamb wave mode conversion and dispersion on the imaging results is overcome. Finally, the TDTE values of the direct sound field and the accompanying sound field are used as the imaging pixel values to improve the imaging accuracy. The experimental results show that for asymmetric blind hole defects, the TDTE imaging method is more accurate than the total focus (TFM) imaging method; the sparse array designed by the genetic algorithm has good sidelobe characteristics and can effectively reduce sidelobe noise assuming the array aperture is unchanged. The TDTE imaging results based on the sparse array data show that the imaging efficiency is greatly improved compared with the full array when the receiving array is four elements under the condition of ensuring the imaging quality.
引用
收藏
页码:20910 / 20920
页数:11
相关论文
共 50 条
  • [1] Using Lamb wave TDTE method to realize ultrasonic array super-resolution imaging of multiple asymmetric defects
    Sun, Liu-Jia
    Zhu, Wen-Fa
    Shao, Wei
    Zheng, Shu-Bin
    Fan, Guo-Peng
    Zhang, Hui
    Li, Zai-Wei
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2021, 332
  • [2] Damage Detection of CFRP laminates by using Ultrasonic Lamb Wave with a Sparse Array
    Xu, Guidong
    Xu, Baiqiang
    Xu, Chenguang
    Luo, Ying
    [J]. FIFTH INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER, 2019, 11046
  • [3] Research on the fusion imaging method of sign coherence and time reversal for Lamb wave sparse array
    Sun, Liu-Jia
    Han, Qing-Bang
    Yin, Cheng
    Jin, Qi-Lin
    Ge, Kao
    [J]. Ultrasonics, 2025, 145
  • [4] Lamb wave TDTE super-resolution imaging assisted by deep learning
    孙刘家
    韩庆邦
    靳琪琳
    [J]. Chinese Physics B., 2025, 34 (01) - 370
  • [5] Array focused Lamb wave Hilbert holographic imaging method
    Lang, Yan-Feng
    Tian, Shao-Hua
    Yang, Zhi-Bo
    Sun, Ruo-Bin
    Zhang, Wei
    Kong, De-Tong
    Chen, Xue-Feng
    [J]. MECHANICS OF ADVANCED MATERIALS AND STRUCTURES, 2023, 30 (04) : 661 - 675
  • [6] Minimum Variance Ultrasonic Imaging Applied to an In Situ Sparse Guided Wave Array
    Hall, James S.
    Michaels, Jennifer E.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (10) : 2311 - 2323
  • [7] Sparse array ultrasonic guided wave tomography
    Bian, HX
    Rose, JL
    [J]. MATERIALS EVALUATION, 2005, 63 (10) : 1035 - 1038
  • [8] Multi Spherical Wave Imaging Method Based on Ultrasonic Array
    Liu, Zhi-Ying
    Zhang, Ping
    Zhang, Bi-Xing
    Wang, Wen
    [J]. SENSORS, 2022, 22 (18)
  • [9] Nonlinear ultrasonic Lamb wave phased array imaging based on hybrid array and time-reversal of harmonic
    Li, Xuan
    Liu, Lishuai
    Xu, Haiming
    Xiang, Yanxun
    Xuan, Fu-Zhen
    [J]. STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2024,
  • [10] Phased-Array Laser Ultrasonic Testing with Sparse Total Focusing Imaging Method
    Kou, Xing
    Pei, Cuixiang
    Wu, Shangzi
    Chen, Zhenmao
    [J]. PROCEEDINGS OF 2019 FAR EAST NDT NEW TECHNOLOGY & APPLICATION FORUM (FENDT), 2019, : 59 - 65