Lixisenatide reduces glycaemic variability in insulin-treated patients with type 2 diabetes

被引:9
|
作者
Umpierrez, Guillermo E. [1 ]
O'Neal, David [2 ]
DiGenio, Andres [3 ]
Goldenberg, Ronald [4 ]
Hernandez-Triana, Eric [5 ]
Lin, Jay [6 ]
Park, Cheol-Young [7 ]
Renard, Eric [8 ,9 ,10 ]
Kovatchev, Boris [11 ]
机构
[1] Emory Univ Med, Dept Med, 1648 Pierce Dr NE, Atlanta, GA 30307 USA
[2] Univ Melbourne, St Vincents Hosp, Dept Med, Melbourne, Vic, Australia
[3] AKCEA Therapeut, Cambridge, MA USA
[4] LMC Diabet & Endocrinol, Thornhill, ON, Canada
[5] Univ Rosario, Endocare Res Inst, Bogota, Colombia
[6] Novosys Hlth, Green Brook, NJ USA
[7] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Sch Med, Dept Internal Med,Div Endocrinol & Metab, Seoul, South Korea
[8] Montpellier Univ Hosp, Dept Endocrinol Diabet Nutr, Montpellier, France
[9] INSERM, Clin Invest Ctr 1411, Montpellier, France
[10] Univ Montpellier, CNRS, Inst Funct Gen, INSERM,U1191,UMR 5203, Montpellier, France
[11] Univ Virginia Hlth Syst, Ctr Diabet Technol, Charlottesville, VA USA
来源
DIABETES OBESITY & METABOLISM | 2017年 / 19卷 / 09期
关键词
glycaemic variability; insulin; lixisenatide; type; 2; diabetes; ONCE-DAILY LIXISENATIDE; BASAL INSULIN; RECEPTOR AGONISTS; PLASMA-GLUCOSE; WELL; 24-WEEK;
D O I
10.1111/dom.12930
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Chronic hyperglycaemia and glucose variability are associated with the development of chronic diabetes-related complications. We conducted a pooled analysis of patient-level data from three 24-week, randomized, phase III clinical trials to evaluate the impact of lixisenatide (LIXI) on glycaemic variability (GV) vs placebo as add-on to basal insulin. The main outcome GV measures were standard deviation (s.d.), mean amplitude of glycaemic excursions (MAGE), mean absolute glucose (MAG) level, area under the curve for fasting glucose (AUC-F), and high (HBGI) and low blood glucose index (LBGI). The change in GV metrics over 24weeks and relationships among baseline GV, patient characteristics and outcomes were assessed. Data were pooled from 1198 patients (665 LIXI, 533 placebo). Values for s.d., MAG level, MAGE, HBGI, and AUC-F significantly decreased with LIXI vs placebo, while LBGI values were unchanged. Higher baseline GV measures correlated with older age, longer type 2 diabetes duration, lower body mass index, higher baseline glycated/haemogobin, greater reduction in postprandial glucose (PPG) level, and higher rates of symptomatic hypoglycaemia. These data show that LIXI added to basal insulin significantly reduced GV and PPG excursions vs placebo, without increasing the risk of hypoglycaemia (LBGI).
引用
收藏
页码:1317 / 1321
页数:5
相关论文
共 50 条
  • [1] Lixisenatide added to basal insulin reduces glycaemic variability in patients with type 2 diabetes mellitus
    O'Neal, D.
    Umpierrez, G.
    DiGenio, A.
    Goldenberg, R.
    Hernandez-Triana, E.
    Lin, J.
    Park, C. -Y.
    Renard, E.
    Kovatchev, B.
    [J]. DIABETOLOGIA, 2014, 57 : S342 - S342
  • [2] Pioglitazone reduces insulin requirements and improves glycaemic control in insulin-treated patients with type 2 diabetes: results from PROactive
    Schmitz, O.
    Charbonnel, B.
    Scheen, A.
    [J]. DIABETOLOGIA, 2006, 49 : 489 - 489
  • [3] Low c-peptide is associated with high glycaemic variability and hypoglycaemia in insulin-treated patients with Type 2 diabetes
    Hope, S. V.
    Knight, B. A.
    Shields, B. M.
    Strain, W. D.
    Hattersley, A. T.
    Choudhary, P.
    Jones, A. G.
    [J]. DIABETIC MEDICINE, 2016, 33 : 18 - 18
  • [4] Glycaemic variability and hypoglycaemia are associated with C-peptide levels in insulin-treated type 2 diabetes
    Christensen, M. B.
    Gaede, P.
    Hommel, E.
    Gotfredsen, A.
    Norgaard, K.
    [J]. DIABETES & METABOLISM, 2020, 46 (01) : 61 - 65
  • [5] Sensor and software use for the glycaemic management of insulin-treated type 1 and type 2 diabetes patients
    Ajjan, Ramzi A.
    Abougila, Kamal
    Bellary, Srikanth
    Collier, Andrew
    Franke, Bernd
    Jude, Edward B.
    Rayman, Gerry
    Robinson, Anthony
    Singh, Baldev M.
    [J]. DIABETES & VASCULAR DISEASE RESEARCH, 2016, 13 (03): : 211 - 219
  • [6] ASSESSMENT OF GLYCAEMIC VARIABILITY (GV) IN INSULIN-TREATED ACUTE RESPIRATORY PATIENTS WITH AND WITHOUT DIABETES
    Misra, S.
    Archer, J. R.
    Simmgen, M.
    Jones, P. W.
    Oliver, N. S.
    Baker, E. H.
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A131 - A132
  • [7] Reaching glycaemic targets while minimizing hypoglycaemia in insulin-treated type 2 diabetes patients
    Mathieu, C.
    Robbrecht, S.
    [J]. DIABETES OBESITY & METABOLISM, 2008, 10 : 14 - 23
  • [8] Glycaemic control and cardiovascular risk in insulin-treated patients with type 2 diabetes in Germany and the UK
    Gough, S.
    Frandsen, K. B.
    Toft, A. D.
    [J]. DIABETOLOGIA, 2008, 51 : S395 - S396
  • [9] Insulin glargine/lixisenatide fixed ratio combination improves glycaemic variability in type 2 diabetes
    Aronson, R.
    Umpierrez, G.
    Stager, W.
    Kovatchev, B.
    [J]. DIABETOLOGIA, 2016, 59 : S383 - S383
  • [10] Glycemic Variability as Predictor of Clinical Outcome in Insulin-Treated Patients With Type 2 Diabetes
    Farrokhi, Farnoosh
    Smiley, Dawn
    Pasquel, Francisco
    Peng, Limin
    Newton, Christopher
    Olson, Darin E.
    Jacobs, Sol
    Umpierrez, Guillermo E.
    [J]. DIABETES, 2013, 62 : A245 - A245