Experimental and numerical investigation on withdrawal connectors usage for lateral resistance of timber shear walls structure

被引:2
|
作者
Shao, Feng [1 ]
Wang, Yanshang [2 ]
Lian, Wu [3 ]
Benjeddou, Omrane [4 ]
机构
[1] Qingdao Univ Technol, Coll Architecture & Urban Planning, Qingdao 266033, Shandong, Peoples R China
[2] Qingdao Fire Rescue Detachment, Qingdao 266000, Shandong, Peoples R China
[3] Civil Engn Fabr Technol Dev Co Ltd, Zhengzhou 450001, Peoples R China
[4] Prince Sattam bin Abdulaziz Univ, Coll Engn, Dept Civil Engn, Alkharj 16273, Saudi Arabia
来源
JOURNAL OF BUILDING ENGINEERING | 2021年 / 44卷 / 44期
关键词
Kinematic model; Ply-lam; Connector; Shear wall; Lateral resistance; FRAME WOOD BUILDINGS; MECHANICAL-PROPERTIES; WOODFRAME STRUCTURES; 3-DIMENSIONAL MODEL; SEISMIC ANALYSIS; BEHAVIOR; STRENGTH; CLT;
D O I
10.1016/j.jobe.2021.103266
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) is a feasible option for mid-rise structures in the United States and Canada. United States building standards require that CLT be designed for seismic applications using alternative methods. CLT as a novel structural system is introduced in this paper, using experimental, nonlinear numerical model and kinematic formulation of CLT to examine the effects of models characteristics on CLT performance. In this study, finite element (FE) and kinematic model of CLT panels were constructed. For evaluating the preciseness of the FE model, test data of CLT panels was used. The mechanical characteristics of connections were used to estimate lateral resistances, which were then compared to experimental data. Thus, 4 out of 7 shear wall specimens included withdrawal connectors and one Ply-lam panel. A single panel was split in half in three of the seven shear wall examples. They were basically linked by 2 or 4 connections to make a single panel. The Ply-lam wall-to-floor connections had two or four connectors, and the vertical load was 0, 24 and 120 kN. Therefore, by using kinematic models. The tested data were 6.3-52.7% more than the predicted value. There was a 10% maximum error of maximum shear forces of panels in the finite element analysis which was considerably closer to the test findings. It indicates that the connector's behavior may be used to accurately anticipate the lateral resistance.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Lateral resistance of mass timber shear wall connected by withdrawal-type connectors
    Pang, Sung-Jun
    Ahn, Kyung-Sun
    Kang, Seog Goo
    Oh, Jung-Kwon
    JOURNAL OF WOOD SCIENCE, 2021, 67 (01)
  • [2] Lateral resistance of mass timber shear wall connected by withdrawal-type connectors
    Sung-Jun Pang
    Kyung-Sun Ahn
    Seog Goo Kang
    Jung-Kwon Oh
    Journal of Wood Science, 2021, 67
  • [3] Friction-Based Connectors for Timber Shear Walls: Static Experimental Tests
    Wakashima, Yoshiaki
    Shimizu, Hidemaru
    Ishikawa, Koichiro
    Fujisawa, Yasushi
    Tesfamariam, Solomon
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2019, 25 (02)
  • [4] A numerical study of the seismic behaviour of timber shear walls with slip-friction connectors
    Loo, Wei Y.
    Quenneville, Pierre
    Chouw, Nawawi
    ENGINEERING STRUCTURES, 2012, 34 : 233 - 243
  • [5] EXPERIMENTAL STUDY OF THE LATERAL RESISTANCE OF CFS SHEAR WALLS
    Baldassino, Nadia
    Manzini, Lorenzo
    Zandonini, Riccardo
    ce/papers, 2024, 7 (1-2) : 145 - 154
  • [6] Lateral-Load Resistance of Cross-Laminated Timber Shear Walls
    Reynolds, Thomas
    Foster, Robert
    Bregulla, Julie
    Chang, Wen-Shao
    Harris, Richard
    Ramage, Michael
    JOURNAL OF STRUCTURAL ENGINEERING, 2017, 143 (12)
  • [7] Experimental and Numerical Investigation of the Shear Performance of PSCC Shear Connectors with Poured UHPC
    Zhou, Fengli
    Guo, Chunwu
    Zhang, Jiangtao
    Guo, Jincen
    Jiang, Jinlong
    Ning, Lulin
    BUILDINGS, 2023, 13 (01)
  • [8] Experimental investigation of OSB sheathed timber frame shear walls with strong anchorage subjected to cyclic lateral loading
    Marzaleh, Abdollah Sadeghi
    Steiger, Rene
    ENGINEERING STRUCTURES, 2021, 226
  • [9] Experimental investigation on fire resistance of sandwich composite walls with truss connectors
    Du, Er-feng
    Shu, Gan -ping
    Qin, Le
    Lai, Bing -lin
    Zhou, Xiong-liang
    Zhou, Guan-gen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 188
  • [10] Experimental investigation on the lateral performance of CLT shear walls connected to perpendicular walls
    Ruggeri, Elisabetta Maria
    D'Arenzo, Giuseppe
    Cavoli, Denise Li
    Cottonaro, Rosario Davide
    Fossetti, Marinella
    XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 464 - 471