Use of smart glasses for ultrasound-guided peripheral venous access: a randomized controlled pilot study

被引:10
|
作者
Lim, Hyunmook [1 ]
Kim, Min Joung [2 ]
Park, Joon Min [1 ]
Kim, Kyung Hwan [1 ]
Park, Junseok [1 ]
Shin, Dong Wun [1 ]
Kim, Hoon [1 ]
Jeon, Woochan [1 ]
Kim, Hyunjong [1 ]
Kim, Jungeon [1 ]
机构
[1] Inje Univ, Dept Emergency Med, Ilsan Paik Hosp, 170 Juhwa Ro, Goyang 10380, South Korea
[2] Yonsei Univ, Dept Emergency Med, Coll Med, Seoul, South Korea
来源
基金
新加坡国家研究基金会;
关键词
Wearable electronic devices; Ultrasonography; Wireless technology; INTRAVENOUS CANNULATION; CHILDREN;
D O I
10.15441/ceem.19.029
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective Smart glasses can provide sonographers with real-time ultrasound images. In the present study, we aimed to evaluate the utility of smart-glasses for ultrasound-guided peripheral venous access. Methods In this randomized, crossover-design, simulation study, 12 participants were recruited from the emergency department residents at a university hospital. Each participant attempted ultrasound-guided peripheral venous access on a pediatric phantom at intervals of 5 days with (glasses group) or without (non-glasses group) the use of smart glasses. In the glasses group, participants confirmed the ultrasound image through the lens of the smart glasses. In the non-glasses group, participants confirmed the ultrasound image through the display viewer located next to the phantom. Procedure time was regarded as the primary outcome, while secondary outcomes included the number of head movements for the participant, number of skin punctures, number of needle redirections, and subjective difficulty. Results No significant differences in procedural time were observed between the groups (non-glasses group: median time, 15.5 seconds; interquartile range [IQR], 10.3 to 27.3 seconds; glasses group: median time, 19.0 seconds; IQR, 14.3 to 39.3 seconds; P=0.58). The number of head movements was lower in the glasses group than in the non-glasses group (glasses group: median, 0; IQR, 0 to 0; non-glasses group: median, 4; IQR, 3 to 5; P<0.01). No significant differences in the number of skin punctures or needle restrictions were observed between the groups. Conclusion Our results indicate that smart-glasses may aid in ensuring ultrasound-guided peripheral venous access by reducing head movements.
引用
收藏
页码:356 / 361
页数:6
相关论文
共 50 条
  • [1] Ultrasound-guided peripheral venous access
    Fuzier, Regis
    Rouge, Pierre
    Pierre, Sebastien
    PRESSE MEDICALE, 2016, 45 (02): : 177 - 182
  • [2] Ultrasound-guided peripheral venous access: a systematic review of randomized-controlled trials
    Liu, Yiju Teresa
    Alsaawi, Abdulmohsen
    Bjornsson, Hjalti M.
    EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2014, 21 (01) : 18 - 23
  • [3] Ultrasound-guided peripheral venous access: Is it the standard of care?
    Tobias, Joseph D.
    ANAESTHESIA PAIN & INTENSIVE CARE, 2015, 19 (03) : 226 - 228
  • [4] A new device for ultrasound-guided peripheral venous access
    Brugioni, Lucio
    Barchetti, Marco
    Tazzioli, Giovanni
    Gelmini, Roberta
    Girardis, Massimo
    Bianchini, Marcello
    Schepis, Filippo
    Nicolini, Matteo
    Pinelli, Giovanni
    Martella, Pietro
    Barozzi, Marco
    Mori, Francesca
    Scarabottini, Serena
    Righetti, Andrea
    Ravazzini, Mirco
    Bertellini, Elisabetta
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (03): : 325 - 328
  • [5] Response to "Pitfalls in ultrasound-guided peripheral venous access"
    Tsubota, Mami
    Sasano, Hiroshi
    JOURNAL OF ANESTHESIA, 2025,
  • [6] Ultrasound-guided peripheral intravenous access in adults: A randomized crossover controlled trial
    Kuo, Chia-Chi
    Lee, Wei-Jing
    Ke, Ya-Ting
    INTERNATIONAL EMERGENCY NURSING, 2025, 79
  • [7] How I Teach: Ultrasound-guided Peripheral Venous Access
    Gorgone, Matthew
    O'Connor, Timothy P.
    Maximous, Stephanie I.
    ATS SCHOLAR, 2022, 3 (04): : 598 - 609
  • [8] Technique of ultrasound-guided peripheral venous access in the emergency room
    MG Annetta
    G Scoppettuolo
    M Biancone
    F Toni
    M Pittiruti
    Critical Care, 17 (Suppl 2):
  • [9] A randomized study of training with large versus small vessel size on successful ultrasound-guided peripheral venous access
    Davis, Joshua
    Faust, Timothy
    Tajani, Azeem
    Bates, Amanda
    Jarriel, Jenna
    Au, Arthur
    Fields, Jason Matthew
    JOURNAL OF VASCULAR ACCESS, 2017, 18 (02): : 163 - 166
  • [10] Ultrasound-guided oblique approach for peripheral venous access in a phantom model
    Tassone, Heather M.
    Tayal, Vivek S.
    Weekes, Anthony J.
    Garner, Craymon L.
    Norton, James H.
    CRITICAL ULTRASOUND JOURNAL, 2012, 4