Application of a new source model of a panoramic gamma irradiator on dose map formation in an irradiated product

被引:6
|
作者
Gual, Maritza R. [1 ,2 ]
Pereira, Claubia [3 ]
Mesquita, Amir Z. [1 ]
机构
[1] Ctr Desenvolvimento Tecnol Nucl, Campus UFMG, BR-31270901 Belo Horizonte, MG, Brazil
[2] Fac Sabara, Rodovia Sabara,Km 14,1084, BR-34555000 Sabara, MG, Brazil
[3] Univ Fed Minas Gerais, Dept Engn Nucl, BR-31270901 Belo Horizonte, MG, Brazil
关键词
GammaBeam; 127; Panoramic gamma irradiator; Dose map; MCNPX; Gamma irradiation facility; RADIATION;
D O I
10.1016/j.apradiso.2018.12.002
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The computer simulation of radiation processing in an industrial panoramic gamma facility generates a number of complex scientific and technical problems; for example, the product is manually loaded onto turntables and rotates during the entire irradiation and the Monte Carlo MCNP three-dimensional geometry simulation is static. This causes the first problem; for this it is necessary to introduce additional approaches to describe the real irradiation process. It is important to properly represent the irradiation process and the specific conditions of the irradiator to correctly reproduce the measured results and guarantee also through the use of the model developed the most accurate dose map formations in an irradiated product, improving the service quality provided to the customer. The objective of this study is to apply the proposed source model of a panoramic gamma irradiator on dose distributions in containers of different geometric shape of an irradiated product with use of the Monte Carlo code. The influence was studied with use of a new homogenized annular source model. The validation of the MCNPX model of the GammaBeam 127 source was performed by measurements. The validation of the proposed model was based on comparative evaluation of the MCNPX absorbed-dose rates (Gy/h) in the irradiated product between the real source model and the new model. The comparative results for the MCNPX absorbed-dose rate showed that the new source model provides a better description of the irradiation process in a panoramic gamma irradiator. This indicates that the physical and mathematical MCNPX models developed are reliable and correct, and the new source model adequately reproduces the observed dose distributions in the different geometric shapes of the irradiated product.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 50 条
  • [1] New source models to represent the irradiation process in panoramic gamma irradiator
    Gual, Maritza R.
    Milian, Felix. M.
    Mesquita, Amir Z.
    Pereira, Claubia
    [J]. APPLIED RADIATION AND ISOTOPES, 2017, 128 : 175 - 182
  • [2] Dose Rate Simulation of a Panoramic Gamma Irradiator using the MCNPX Code and Comparison with Measurements
    Kim, Yong Ho
    Park, Jae Woo
    [J]. JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 325 - 328
  • [3] Estimation of DUR and source utilization efficiency for changing product dimensions and source activities in gamma irradiator
    George, Jain Reji
    Pradhan, A. S.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2009, 78 (11) : 1011 - 1014
  • [4] Monte Carlo Simulation of the Dose Rate Distribution of a Moroccan Panoramic Gamma Irradiator Using the MCNPX Code
    Aknouch, A.
    Mouhib, M.
    Sebihi, R.
    Didi, A.
    El-ouardi, Y.
    Boubekraoui, A.
    Choukri, A.
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2020, 75 (01) : 35 - 38
  • [5] Monte Carlo Simulation of the Dose Rate Distribution of a Moroccan Panoramic Gamma Irradiator Using the MCNPX Code
    A. Aknouch
    M. Mouhib
    R. Sebihi
    A. Didi
    Y. El-ouardi
    A. Boubekraoui
    A. Choukri
    [J]. Moscow University Physics Bulletin, 2020, 75 : 35 - 38
  • [6] DOSE-RATE FIELD OF AN IRRADIATOR WITH USED FUEL ELEMENTS AS SOURCE OF GAMMA RADIATION
    DROZDOV, VE
    ZAKHAROV.IM
    DOBROVOL.SP
    [J]. JOURNAL OF NUCLEAR ENERGY PARTS A AND B-REACTOR SCIENCE AND TECHNOLOGY, 1966, 20 (1112): : 1011 - &
  • [7] MONTE CARLO SIMULATION OF VARIOUS SOURCE-PRODUCT GEOMETRIES FOR A PROPOSED MULTI-PRODUCT GAMMA IRRADIATOR FACILITY
    Biju, K.
    Selvam, T. Palani
    Lavale, D. S.
    [J]. HEALTH PHYSICS, 2009, 97 (03): : 187 - 194
  • [8] Design and Application of Mobile Panoramic Map Based on Sphere Model
    Liu Xianxiong
    Hu Qingwu
    Aimingyao
    [J]. 2015 23RD INTERNATIONAL CONFERENCE ON GEOINFORMATICS, 2015,
  • [9] Influence of Dose Uniformity when Replicating a Gamma Knife Mouse Model of Radiation Necrosis with a Preclinical Irradiator
    Boria, Andrew J.
    Perez-Torres, Carlos J.
    [J]. RADIATION RESEARCH, 2019, 191 (04) : 352 - 359
  • [10] Development of an algorithm for gamma dose mapping in irradiated product using TOPSIS and its validation
    Singh, Meghraj
    Datta, D.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2020, 177