Stress Calculation Method for Overhead Line Conductors under Ice Overload Condition Considering Material Plasticity

被引:0
|
作者
Liu Changsheng [1 ]
You Buxin [2 ]
Liu Jun [1 ]
Liu Hezhi [2 ]
Xie Yunyun [3 ]
Zhang Lianhua [3 ]
机构
[1] State Grid Chongqing Elect Power Co, Chongqing, Peoples R China
[2] State Grid Chongqing Jiangjin Elect Power Supply, Chongqing, Peoples R China
[3] Nanjing Univ Sci & Technol, Sch Automat, Nanjing, Jiangsu, Peoples R China
关键词
Ice overload; Plastic deformation; Equations of state; Stress calculation;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Wire behaves plastically in its elastic range. Without considering the wire plastic deformation, the calculation results of wire stress in overload condition will be conservative. So this paper established the state equation of stress changes based on wire strain curves when the wire is ice overloaded and the produced stress exceeds the limit. Considering the wire strain curves, a new calculating method of the stress was introduced when the wire's stress beyond the tensile strength. Simulation result shows that the method is valid.
引用
收藏
页数:4
相关论文
共 16 条
  • [1] Elongation of overhead line conductors under combined mechanical and thermal stress
    Michael, Muhr
    Stephan, Pack
    Stefan, Jaufer
    [J]. PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 671 - 674
  • [2] A numerical calculation of the impact of ice-shedding from overhead line conductors on interphase spacers
    Zemljaric, Borut
    [J]. ELEKTROTEHNISKI VESTNIK, 2022, 89 (04): : 156 - 162
  • [3] Derivation and Verification of a Calculation Method for the Overhead Line Voltage Measurement considering the Influence of the Earth Conductor
    Burkhardt, Erwin
    Jenau, Frank
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2018,
  • [4] The Comparison of Conductor Stress Calculation Methods for Overhead Line under Extreme Weather Conditions
    Liu Jun
    Jiang Dingyou
    Wei Xu
    Liu Hezhi
    Xie Yunyun
    Jin Ying
    [J]. 2013 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2013,
  • [5] A Calculation Method for the Lightning Flashover Rate of 10 kv Overhead Line Considering the Influence of Nearby Buildings
    Lei, Ting
    Shen, Haibin
    Zhao, Xia
    Lu, Tiantian
    [J]. 2024 THE 7TH INTERNATIONAL CONFERENCE ON ENERGY, ELECTRICAL AND POWER ENGINEERING, CEEPE 2024, 2024, : 329 - 334
  • [6] New thermo-magnetic material wire used for self-protection high voltage line overhead conductors against frost/ice deposits
    National Institute for Research and Development in Electrical Engineering ICPE-CA, 313 Splaiul Unirii, Bucharest-3, code 030138, Romania
    [J]. Codescu, M. (mirela.codescu@icpe-ca.ro), 1600, National Institute of Optoelectronics (07): : 1 - 2
  • [7] New thermo-magnetic material wire used for self-protection high voltage line overhead conductors against frost/ice deposits
    Iorga, A.
    Codescu, M.
    Palii, L.
    [J]. OPTOELECTRONICS AND ADVANCED MATERIALS-RAPID COMMUNICATIONS, 2013, 7 (1-2): : 86 - 89
  • [8] Calculation method of creep under decreasing stress considering variation of natural environmental factors
    Zhao, Yu
    Wang, Yan
    Song, Chuang
    Zhou, Yongjun
    [J]. 2019 5TH INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY RESOURCES AND ENVIRONMENT ENGINEERING (ICAESEE 2019), 2020, 446
  • [9] Segmental insulation design method for UHV DC overhead ground wires under ice-melting with normal working condition
    Li, Peng
    Zhang, Dawei
    lei, Mengfei
    Xiao, Pan
    Wu, Tian
    Fang, Chunhua
    Pu, Ziheng
    [J]. Electric Power Systems Research, 2025, 238