Residual stress evaluation within hydroxyapatite coatings of different micrometer thicknesses

被引:10
|
作者
Edreira, Eva R. Urquia [1 ]
Wolke, Joop G. C. [1 ]
Riet, Joost te [2 ,3 ]
Kotnur, Girish V. [4 ]
Janssen, G. C. A. M. [4 ]
Jansen, John A. [1 ]
van den Beucken, Jeroen J. J. P. [1 ]
机构
[1] Radboudumc, Dept Biomat, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Inst Mol & Mat, Dept Scanning Probe Microscopy, Nijmegen, Netherlands
[3] Radboudumc, Radboud Inst Mol Life Sci, Dept Tumor Immunol, NL-6500 HB Nijmegen, Netherlands
[4] Delft Univ Technol, Dept Precis & Microsyst Engn, NL-2628 CD Delft, Netherlands
来源
关键词
Calcium phosphate; Radio frequency (RF) magnetron sputtering; Residual stress; X-ray diffraction; Wafer curvature; SILICON-SUBSTITUTED HYDROXYAPATITE; CALCIUM-PHOSPHATE COATINGS; MAGNETRON; DEPOSITION; INTERFACE;
D O I
10.1016/j.surfcoat.2015.02.040
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Bioceramic coatings, including calcium phosphate coatings composed of hydroxyapatite (HA), represent a common surface modification for metallic bone implants. In view of the mismatch in material properties between the ceramic coating material and the metallic substrate material, this study aimed to evaluate the residual stress within an HA-coating deposited using RF magnetron sputtering via two different analyses, based on either the Stoney formula (i.e. based on curvature measurements of the substrate [Stoney, 1909]) or the sin(2)psi method (i.e. based on X-ray diffraction patterns of the coating). Additionally, the effect of HA-coating thickness (i.e. 1 or 4 mu m) on residual stress and surface topography was addressed. We hypothesized that: (i) both methods to determine residual stress would show similar results, and (ii) residual stress would vary between coating thicknesses. The curvature measurements showed low residual stress values (ranging from -60 to 80 MPa) and indicated relaxation upon post-deposition heat treatment at 650 degrees C. Similarly, lattice-based measurements of residual stress showed relaxation of HA coatings upon post-deposition heat treatment. Coating thickness variation in the micrometer scale showed no major effects on residual stress magnitude. For reasons of accuracy and similarity to the actual conditions, determination of residual stress via lattice-based techniques is preferable. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [1] Analysis on Residual Stress in TiN Coating with Different Thicknesses
    Cao, Chuanliang
    Zhang, Xianglin
    Wang, Haiyang
    [J]. ADVANCED MATERIALS AND PROCESS TECHNOLOGY, PTS 1-3, 2012, 217-219 : 1306 - 1311
  • [2] Residual stress evaluation at the micrometer scale: Analysis of thin coatings by FIB milling and digital image correlation
    Korsunsky, Alexander M.
    Sebastiani, Marco
    Bemporad, Edoardo
    [J]. SURFACE & COATINGS TECHNOLOGY, 2010, 205 (07): : 2393 - 2403
  • [3] RESIDUAL-STRESS MEASUREMENT IN THERMAL SPRAYED HYDROXYAPATITE COATINGS
    BROWN, SR
    TURNER, IG
    REITER, H
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (9-10) : 756 - 759
  • [4] Residual stress in hydroxyapatite coatings and implications for bond strength.
    Tufekci, E
    Brantley, W
    Foreman, D
    Soto, U
    Georgette, F
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 : 122 - 122
  • [5] In vivo evaluation of hydroxyapatite coatings of different crystallinities
    Oh, S
    Tobin, E
    Yang, YZ
    Carnes, PL
    Ong, JL
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (05) : 726 - 731
  • [6] Residual stress evaluation of hydroxyapatite coating Ti implant
    Tadano, S
    Todoh, M
    Shibano, J
    Ukai, T
    [J]. JSME INTERNATIONAL JOURNAL SERIES A-SOLID MECHANICS AND MATERIAL ENGINEERING, 1997, 40 (03): : 328 - 335
  • [7] Biomechanical evaluation of different hydroxyapatite coatings on titanium for keratoprosthesis
    Ying DONG
    Zhiye QIU
    Xiaoyu LIU
    Liqiang WANG
    Jingxin YANG
    Yifei HUANG
    Fuzhai CUI
    [J]. Frontiers of Materials Science., 2015, 9 (03) - 310+208
  • [8] Biomechanical evaluation of different hydroxyapatite coatings on titanium for keratoprosthesis
    Ying Dong
    Zhiye Qiu
    Xiaoyu Liu
    Liqiang Wang
    Jingxin Yang
    Yifei Huang
    Fuzhai Cui
    [J]. Frontiers of Materials Science, 2015, 9 : 303 - 310
  • [9] Biomechanical evaluation of different hydroxyapatite coatings on titanium for keratoprosthesis
    Dong, Ying
    Qiu, Zhiye
    Liu, Xiaoyu
    Wang, Liqiang
    Yang, Jingxin
    Huang, Yifei
    Cui, Fuzhai
    [J]. FRONTIERS OF MATERIALS SCIENCE, 2015, 9 (03) : 303 - 310
  • [10] Evaluation of electrical resistivity, residual stress and surface roughness of sputtering indium tin oxide films with different thicknesses
    Tien, Chuen-Lin
    Lin, Tsai-Wei
    Su, Shu-Hui
    [J]. OPTICA APPLICATA, 2021, 51 (04) : 499 - 512