Monte Carlo Simulations Applied to Conjunctival Lymphoma Radiotherapy Treatment

被引:15
|
作者
Brualla, Lorenzo [1 ]
Palanco-Zamora, Ricardo [2 ]
Steuhl, Klaus-Peter [3 ]
Bornfeld, Norbert [4 ]
Sauerwein, Wolfgang [1 ]
机构
[1] Univ Klinikum Essen, Strahlenklin, NCTeam, D-45122 Essen, Germany
[2] Karolinska Univ Hosp, Stockholm, Sweden
[3] Univ Klinikum Essen, Klin Erkrankungen Vorderen Augenabschnittes, D-45122 Essen, Germany
[4] Univ Klinikum Essen, Klin Erkrankungen Hinteren Augenabschnittes, D-45122 Essen, Germany
关键词
Radiotherapy; Monte Carlo; Variance-reduction; Linac; Small fields; PENCIL BEAM; FIELDS; DOSIMETRY; THERAPY;
D O I
10.1007/s00066-011-2237-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Small radiation fields are increasingly applied in clinical routine. In particular, they are necessary for the treatment of eye tumors. However, available treatment planning systems do not calculate the absorbed dose with the desired accuracy in the presence of small fields. Absorbed dose estimations obtained with Monte Carlo methods have the required accuracy for clinical applications, but the exceedingly long computation times associated with them hinder their routine use. In this article, a code for automatic Monte Carlo simulation of linacs and an application in the treatment of conjunctival lymphoma are presented. Methods: Simulations of clinical linear accelerators were performed with the general-purpose radiation transport Monte Carlo code PENELOPE. Accelerator geometry files, in electron mode, were generated with the program AutolinaC. Results: The Monte Carlo simulation of an annular electron 6 MeV field used for the treatment of the conjunctival lymphoma yielded absorbed dose results statistically compatible with experimental measurements. In this simulation, 2% standard statistical uncertainty was reached in the same time employed by a hybrid Monte Carlo commercial code (eMC); however, eMC showed discrepancies of up to 7% on the absorbed dose with respect to experimental data. Results obtained with the analytic algorithm Pencil Beam Convolution differed from experimental data by 10% for this case. Conclusion: Owing to the systematic application of variance-reduction techniques, it is possible to accurately estimate the absorbed dose in patient images, using Monte Carlo methods, in times within clinical routine requirements. The program AutolinaC allows systematic use of these variance-reduction techniques within the code PENELOPE.
引用
收藏
页码:492 / 498
页数:7
相关论文
共 50 条
  • [1] Monte Carlo Simulations Applied to Conjunctival Lymphoma Radiotherapy TreatmentMonte-Carlo-Simulation der Strahlentherapie von konjunktivalen Lymphomen
    Lorenzo Brualla
    Ricardo Palanco-Zamora
    Klaus-Peter Steuhl
    Norbert Bornfeld
    Wolfgang Sauerwein
    Strahlentherapie und Onkologie, 2011, 187 : 492 - 498
  • [2] Comparison between PENELOPE and electron Monte Carlo simulations of electron fields used in the treatment of conjunctival lymphoma
    Brualla, L.
    Palanco-Zamora, R.
    Wittig, A.
    Sempau, J.
    Sauerwein, W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (18): : 5469 - 5481
  • [3] Monte Carlo simulations in radiotherapy dosimetry
    Pedro Andreo
    Radiation Oncology, 13
  • [4] Monte Carlo simulations in radiotherapy dosimetry
    Andreo, Pedro
    RADIATION ONCOLOGY, 2018, 13
  • [5] Comparison of Treatment Planning Algorithms and Monte Carlo Simulations in Oesophageal Radiotherapy
    Johns, D.
    Spezi, E.
    Downes, P.
    Lewis, D.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S776 - S776
  • [6] Optimisation of the treatment technique used for the conjunctival lymphoma by means of Monte Carlo simulations and dose volume histograms on high resolution CT images
    Brualla, L.
    Zaragoza, F. J.
    Sempau, J.
    Wittig, A.
    Sauerwein, W.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 : 77 - 77
  • [7] Monte Carlo for Radiotherapy Treatment Planning
    Ma, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [8] Monte Carlo Simulations of a Novel Kilovoltage Radiotherapy Source
    Bazalova, M.
    Weil, M.
    Graves, E.
    MEDICAL PHYSICS, 2011, 38 (06) : 3767 - +
  • [9] Monte Carlo Simulations for Photon Energy Modulation in Radiotherapy
    Park, J.
    Ye, S.
    Kim, I.
    Kim, J.
    Choi, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [10] An overview of Monte Carlo treatment planning for radiotherapy
    Spezi, Emiliano
    Lewis, Geraint
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (01) : 123 - 129