Markerless Real-Time 3-Dimensional kV Tracking of Lung Tumors During Free Breathing Stereotactic Radiation Therapy

被引:20
|
作者
de Bruin, Kimmie [1 ]
Dahele, Max [1 ]
Mostafavi, Hassan [2 ]
Slotman, Berend J. [1 ]
Verbakel, Wilko F. A. R. [1 ]
机构
[1] Vrije Univ Amsterdam, Amsterdam UMC, Dept Radiat Oncol, Canc Ctr Amsterdam, Amsterdam, Netherlands
[2] Varian Med Syst, Palo Alto, CA USA
关键词
COMPUTED-TOMOGRAPHY; MOTION MANAGEMENT; VERIFICATION; RADIOTHERAPY; PATTERNS; POSITION; CANCER;
D O I
10.1016/j.adro.2021.100705
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Accurate verification of tumor position during irradiation could reduce the probability of target miss. We investigated whether a commercial gantry-mounted 2-dimensional (2D) kilo-voltage (kV) imaging system could be used for real-time 3D tumor tracking during volumetric modulated arc therapy (VMAT) lung stereotactic body radiation therapy (SBRT). Markerless tumor tracking on kV fluoroscopic images was validated using a life-like moving thorax phantom and subsequently performed on kV images continuously acquired before and during free-breathing VMAT lung SBRT. Methods and Materials: The 3D-printed/molded phantom containing 3 lung tumors was moved in 3D in TrueBeam developer mode, using simulated regular/irregular breathing patterns. Planar kV images were acquired at 7 frames/s during 11 Gy/fraction 10 MV flattening filter free VMAT. 2D reference templates were created for each gantry angle using the planning 4D computed tomography inspiration phase. kV images and templates were matched using normalized cross correlation to determine 2D tumor position, and triangulation of 2D matched projections determined the third dimension. 3D target tracking performed on cone beam computed tomography projection data from 18 patients (20 tumors) and real-time online tracking data from 2 of the 18 patients who underwent free-breathing VMAT lung SBRT are presented. Results: For target 1 and 2 of the phantom (upper lung and middle/medial lung, mean density -130 Hounsfield units), 3D results within 2 mm of the known position were present in 92% and 96% of the kV projections, respectively. For target 3 (inferior lung, mean density -478 Hounsfield units) this dropped to 80%. Benchmarking against the respiratory signal, 13/20 (65%) tumors (10.5 +/- 11.1 cm(3)) were considered successfully tracked on the cone beam computed tomography data. Tracking was less successful (<= 50% of the time) in 7/20 (1.2 +/- 1.5 cm(3)). Successful online tracking during lung SBRT was demonstrated. Conclusions: 3D markerless tumor tracking on a standard linear accelerator using template matching and triangulation of free-breathing kV fluoroscopic images was possible in 65% of small lung tumors. The smallest tumors were most challenging. (C) 2021 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Markerless Real-Time 3D kV Tracking of Lung Tumors During Free Breathing Stereotactic Radiotherapy
    De Bruin, K.
    Dahele, M.
    Mostafavi, H.
    Slotman, B.
    Verbakel, W. F. A. R.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S882 - S882
  • [2] Real-time Tracking of Markerless Lung Tumors During SBRT With Continuous MV Imaging
    Rottmann, J.
    Yue, Y.
    Chen, A.
    Kozono, D.
    Mak, R.
    Hacker, F.
    Berbeco, R. I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S200 - S200
  • [3] Coded Aperture Scatter Imaging for Real-Time, Markerless Tracking of Lung Tumors
    Mahl, A.
    Miller, B.
    Altunbas, C.
    Kavanagh, B.
    Miften, M.
    Jones, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E342 - E343
  • [4] REAL-TIME 3-DIMENSIONAL TRACKING OF CILIATES
    KUHNELKRATZ, C
    HADER, DP
    JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY B-BIOLOGY, 1993, 19 (03) : 193 - 200
  • [5] Dual Energy Fluoroscopy for Markerless Motion Tracking of Lung Tumors in Stereotactic Body Radiation Therapy (SBRT)
    Block, A. M.
    Patel, R.
    Harkenrider, M. M.
    Surucu, M.
    Roeske, J. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : S41 - S42
  • [6] STEREOTACTIC BODY RADIATION THERAPY WITH REAL-TIME TRACKING FOR HEPATOCELLULAR CARCINOMA
    Bibault, Jean-Emmanuel
    Lacornerie, Thomas
    Dewas, Sylvain
    Fumagalli, Ingrid
    Jerraya, Hajer
    Lartigau, Eric
    Mirabel, Xavier
    ANNALS OF ONCOLOGY, 2012, 23 : 57 - 57
  • [7] Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors
    Uchida, Yukihiro
    Tachibana, Hidenobu
    Kamei, Yoshiyuki
    Kashihara, Kenichi
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2017, 43 : 100 - 106
  • [8] Peripheral Early-Stage Lung Tumors Treated With Real-time Tumor Tracking During Stereotactic Radiation Therapy: A 6-year Experience
    Nuyttens, J.
    van Zyp, N. C. Van der Voort
    Hoogeman, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S581 - S582
  • [9] Accuracy of Real-time Couch Tracking During 3-dimensional Conformal Radiation Therapy, Intensity Modulated Radiation Therapy, and Volumetric Modulated Arc Therapy for Prostate Cancer
    Wilbert, Juergen
    Baier, Kurt
    Hermann, Christian
    Flentje, Michael
    Guckenberger, Matthias
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (01): : 237 - 242
  • [10] Deep inspiration breath hold real-time tumor-tracking radiation therapy (DBRT) as a novel stereotactic body radiation therapy approach for lung tumors
    Tanaka, Hidekazu
    Ono, Taiki
    Ueda, Kazushi
    Karita, Masako
    Manabe, Yuki
    Kajima, Miki
    Sera, Tatsuhiro
    Fujimoto, Koya
    Yuasa, Yuki
    Shiinoki, Takehiro
    SCIENTIFIC REPORTS, 2024, 14 (01)