Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle

被引:70
|
作者
Goldich, Yakov [1 ]
Barkana, Yaniv [1 ]
Pras, Eran [1 ]
Fish, Alexander [4 ,5 ]
Mandel, Yossi [2 ]
Hirsh, Ami [3 ]
Tsur, Nir [1 ]
Morad, Yair [1 ]
Avni, Isaac [1 ]
Zadok, David [1 ]
机构
[1] Tel Aviv Univ, Assaf Harofeh Med Ctr, Dept Ophthalmol, IL-70300 Zerifin, Israel
[2] Hebrew Univ Jerusalem, Serv Humanity & Soc, Ctr Bioengn, Jerusalem, Israel
[3] Einaim Refract Surg Ctr, Jerusalem, Israel
[4] Netherlands Canc Inst, Div Biochem, Amsterdam, Netherlands
[5] Netherlands Canc Inst, Ctr Biomed Genet, Amsterdam, Netherlands
来源
关键词
OCULAR RESPONSE ANALYZER; IN-SITU KERATOMILEUSIS; HORMONE RECEPTORS; KERATOCONIC EYES; WOMEN;
D O I
10.1016/j.jcrs.2011.03.038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess variations in the biomechanical properties and central corneal thickness (CCT) throughout the female menstrual cycle. SETTING: Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin Israel. DESIGN: Case series. METHODS: Young healthy women were prospectively recruited. Every participant was assessed at the beginning of the menstrual cycle, at ovulation, and at the end of the cycle. At every time point, corneal hysteresis (CH) and the corneal resistance factor (CRF) were measured with the Ocular Response Analyzer and the CCT was measured with an ultrasonic pachymeter. RESULTS: Twenty-two eyes of 22 women (mean age 19.5 years +/- 1.5 [SD]) were included. The CH was statistically significantly decreased at ovulation (10.1 mm Hg) compared with the beginning (11.1 mm Hg, P<.001) and the end (11.4 mm Hg, P<.001) of the cycle. The CRF was also significantly decreased at ovulation (9.8 mm Hg) compared with the beginning (10.6 mm Hg, P<.001) and the end (10.5 mm Hg, P<.001) of the cycle. The central cornea was thinnest at the beginning (535 pm) and statistically significantly thicker at ovulation (542 mu m, P<.001) and at the end of the menstrual cycle (543 mu m, P<.001). CONCLUSIONS: The CCT and biomechanical parameters significantly varied during the menstrual cycle. The CH and CRF were temporarily decreased at ovulation. The cornea was thinnest at the beginning and thicker at ovulation and at the end of the cycle. Such corneal changes may be important to consider during screening of candidates for laser refractive surgery.
引用
收藏
页码:1507 / 1511
页数:5
相关论文
共 50 条
  • [1] Variations in central corneal thickness during the menstrual cycle in women
    Giuffre, Giuseppe
    Di Rosa, Luigi
    Fiorino, Fabio
    Bubella, Daniele Morreale
    Lodato, Gaetano
    [J]. CORNEA, 2007, 26 (02) : 144 - 146
  • [2] Variations in the central corneal thickness during the menstrual cycle in Indian women
    Mishra, Deepak
    Bhushan, Prashant
    Sachan, Shikha
    Singh, M. K.
    Jayadev, Chaitra
    Kusumgar, Pallak
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (12) : 2918 - 2920
  • [3] Corneal Biomechanical Properties during the Menstrual Cycle
    Seymenoglu, Guktug
    Baser, Esin F.
    Zerdeci, Nehir
    Gulhan, Ceren
    [J]. CURRENT EYE RESEARCH, 2011, 36 (05) : 399 - 403
  • [4] MENSTRUAL-CYCLE VARIATIONS OF CORNEAL TOPOGRAPHY AND THICKNESS
    KIELY, PM
    CARNEY, LG
    SMITH, G
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1983, 60 (10): : 822 - 829
  • [5] CHANGES IN CENTRAL AND PERIPHERAL CORNEAL THICKNESS WITH MENSTRUAL-CYCLE
    ELHAGE, SG
    BEAULNE, C
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1973, 50 (11): : 863 - 871
  • [6] CHANGES IN CENTRAL AND PERIPHERAL CORNEAL THICKNESS WITH MENSTRUAL-CYCLE
    ELHAGE, SG
    BEAULNE, C
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1972, 49 (10): : 881 - &
  • [7] Corneal Biomechanical Parameters and Central Corneal Thickness in Glaucoma Patients, Glaucoma Suspects, and a Healthy Population
    Angeles del Buey-Sayas, Ma
    Lanchares-Sancho, Elena
    Campins-Falco, Pilar
    Dolores Pinazo-Duran, Maria
    Peris-Martinez, Cristina
    [J]. JOURNAL OF CLINICAL MEDICINE, 2021, 10 (12)
  • [8] Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement
    Zofia Pniakowska
    Piotr Jurowski
    [J]. Scientific Reports, 13
  • [9] Central Corneal Thickness and Biomechanical Changes After Clear Corneal Phacoemulsification
    de Freitas, Bruno
    Ventura, Marcelo Palis
    da Silva, Renata Siqueira
    Canedo, Ana Laura
    Velarde, Guillermo Coca
    Ambrosio, Renato, Jr.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) : 215 - 219
  • [10] Early influence of endotamponade on corneal biomechanical parameters, central corneal thickness and accuracy of intraocular pressure measurement
    Pniakowska, Zofia
    Jurowski, Piotr
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)