Plume Stability During Direct Contact Condensation of Steam in a Crossflow of Subcooled Water, at High Mass Flux and With a Small Nozzle Diameter

被引:6
|
作者
Alden, Zach R. [1 ]
Maples, Gunnar D. [1 ]
Dressler, Kristofer M. [1 ]
Nellis, Gregory F. [2 ]
Berson, Arganthael [1 ]
机构
[1] Univ Wisconsin, Multiphase Flow Visualizat & Anal Lab, 1500 Engn Dr, Madison, WI 53706 USA
[2] Univ Wisconsin, Solar Energy Lab, 1500 Engn Dr, Madison, WI 53706 USA
来源
关键词
2ND DOMINANT FREQUENCY; PRESSURE OSCILLATION; JET CONDENSATION; REGIME DIAGRAM; VAPOR BUBBLES; VENT SYSTEM; MECHANISMS; INJECTION; MAP;
D O I
10.1115/1.4051667
中图分类号
O414.1 [热力学];
学科分类号
摘要
The stability of a steam plume during direct-contact condensation into a crossflow of subcooled water is investigated for mass fluxes that are higher (>600 kg/m(2)s) and a nozzle diameter (2.4 mm) that is smaller than typically seen in the literature. The transition from a stable steam plume to an unstable plume associated with the formation and collapse of steam bubbles is characterized by high-speed imaging and high-frequency pressure measurements. Four regimes are observed: stable, condensation oscillation, transition, and unstable. A regime map and spectral signatures of the different flow regimes are provided. Results are compared with correlations from the literature, which are typically derived for lower mass fluxes, larger nozzles, and injection into stagnant pools of water.
引用
收藏
页数:12
相关论文
共 33 条
  • [1] Experimental study on direct contact condensation of saturated steam at low mass flux in subcooled quiescent water
    Kaleem, Muhammad Ahsan
    Shah, Ajmal
    Iqbal, Mazhar
    Quddus, Abdul
    Mehmood, Atif
    Riaz, Ali
    Ayub, Muhammad Khawar
    KERNTECHNIK, 2022, 87 (05) : 547 - 555
  • [2] Direct contact condensation of steam jet in subcooled water: A review
    Wang, Jue
    Chen, Lisheng
    Cai, Qi
    Hu, Chen
    Wang, Cong
    NUCLEAR ENGINEERING AND DESIGN, 2021, 377
  • [3] Heat transfer in direct contact condensation of steam to subcooled water spray
    Takahashi, M
    Nayak, AK
    Kitagawa, S
    Murakoso, H
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2001, 123 (04): : 703 - 710
  • [4] Numerical Investigation on Unstable Direct Contact Condensation of Steam in Subcooled Water
    Jayachandran, K. N.
    Roy, Arnab
    Ghosh, Parthasarathi
    HEAT TRANSFER ENGINEERING, 2021, 42 (07) : 592 - 612
  • [5] Steam plume length diagram for direct contact condensation of steam injected into water
    de With, A.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2009, 30 (05) : 971 - 982
  • [6] The direct contact condensation of steam in a pool at low mass flux
    Youn, DH
    Ko, KB
    Lee, YY
    Kim, MH
    Bae, YY
    Park, JK
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2003, 40 (10) : 881 - 885
  • [7] Research on direct contact condensation of steam-air mixture in subcooled water
    Yang, Xiao-Ping
    Chen, Yi
    Li, Tao
    Zong, Xiao
    Liu, Ji-Ping
    Yan, Jun-Jie
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2015, 36 (11): : 2493 - 2497
  • [8] Experimental analysis of direct contact condensation during vertical injection of steam onto a subcooled water pool
    Patel, Saurabh
    Guleria, Sharey Deep
    Pati, Aniket
    Kumar, Parmod
    PHYSICS OF FLUIDS, 2022, 34 (12)
  • [9] PREDICTION OF HEAT-TRANSFER BY DIRECT CONTACT CONDENSATION AT A STEAM SUBCOOLED WATER INTERFACE
    MURATA, A
    HIHARA, E
    SAITO, T
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (01) : 101 - 109
  • [10] Numerical investigation of heat transfer in direct contact condensation of steam to subcooled water spray
    Ding, Hengtao
    Luo, Yiqing
    Yuan, Xigang
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2019, 140 : 52 - 63