Imaging of amygdala activation during delayed aversive conditioning using single-shot multi-echo fMRI

被引:0
|
作者
Weiskopf, N
Veit, R
Mathiak, K
Grodd, W
Birbaumer, N
机构
[1] Univ Tubingen, Inst Behav Neurobiol, Tubingen, Germany
[2] Univ Tubingen, Sect Exp MR CNS, Tubingen, Germany
[3] Univ Tubingen, Dept Neurol, D-7400 Tubingen, Germany
[4] Univ Padua, Padua, Italy
关键词
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
引用
收藏
页码:S486 / S486
页数:1
相关论文
共 50 条
  • [1] BOLD sensitivity and SNR characteristics of parallel imaging-accelerated single-shot multi-echo EPI for fMRI
    Bhavsar, Saurabh
    Zvyagintsev, Mikhail
    Mathiak, Klaus
    NEUROIMAGE, 2014, 84 : 65 - 75
  • [2] Motion correction of parametric fMRI data from multi-slice single-shot multi-echo acquisitions
    Speck, O
    Hennig, J
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) : 1023 - 1027
  • [4] Ultrafast bold fMRI using single-shot spin-echo echo planar imaging
    Boujraf, Said
    Summers, Paul
    Belahsen, Faouzi
    Pruessmann, Klaas
    Kollias, Spyros
    JOURNAL OF MEDICAL PHYSICS, 2009, 34 (01) : 37 - 42
  • [5] Enhancement of BOLD-contrast sensitivity by single-shot multi-echo functional MR imaging
    Posse, S
    Wiese, S
    Gembris, D
    Mathiak, K
    Kessler, C
    Grosse-Ruyken, ML
    Elghahwagi, B
    Richards, T
    Dager, SR
    Kiselev, VG
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (01) : 87 - 97
  • [6] Single-shot compensation of image optimization using multi-echo EPI distortions and BOLD contrast for real-time fMRI
    Weiskopf, N
    Klose, U
    Birbaumer, N
    Mathiak, K
    NEUROIMAGE, 2005, 24 (04) : 1068 - 1079
  • [7] Single-shot echo planar time-resolved imaging for multi-echo functional MRI and distortion-free diffusion imaging
    Dong, Zijing
    Wald, Lawrence L.
    Polimeni, Jonathan R.
    Wang, Fuyixue
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 993 - 1013
  • [8] Multi-echo single-shot EPI for hyperpolarized 13C cardiac metabolic imaging of small animals
    Andreas Sigfridsson
    Kilian Weiss
    Lukas Wissmann
    Julia Busch
    Marcin Krajewski
    Darach O h-Ici
    Michael Batel
    Georgios Batsios
    Sebastian Kozerke
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)
  • [9] Rapid and accurate measurement of transverse relaxation times using a single shot multi-echo echo-planar imaging sequence
    Tyler, DJ
    Moore, RJ
    Marciani, L
    Gowland, PA
    MAGNETIC RESONANCE IMAGING, 2004, 22 (07) : 1031 - 1037
  • [10] Dynamic field mapping and distortion correction using single-shot blip-rewound EPI and joint multi-echo reconstruction
    Wu, Wenchuan
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (01) : 82 - 97