Next-generation balloon-expandable Myval transcatheter heart valve in low-risk aortic stenosis patients

被引:16
|
作者
Garcia-Gomez, Mario [1 ]
Raul Delgado-Arana, Jose [1 ]
Halim, Jonathan [2 ]
De Marco, Federico [3 ]
Trani, Carlo [4 ]
Martin, Pedro [5 ]
Won-Keun, Kim [6 ]
Montorfano, Matteo [7 ]
den Heijer, Peter [2 ]
Bedogni, Francesco [3 ]
Sardella, Gennaro [8 ]
IJsselmuiden, Alexander J. J. [2 ]
Teles, Rui Campante [9 ]
Aristizabal-Duque, Christian H. [1 ]
Gordillo, Ximena [1 ]
Santos-Martinez, Sandra [1 ]
Barrero, Alejandro [1 ]
Gomez-Salvador, Itziar [1 ]
Ancona, Marco [7 ]
Redondo, Alfredo [1 ]
Alberto San Roman, J. [1 ]
Amat-Santos, Ignacio J. [1 ]
机构
[1] Hosp Clin Univ Valladolid, Cardiol Dept, CIBERCV, Valladolid, Spain
[2] Amphia Hosp Breda, Cardiol Dept, Breda, Netherlands
[3] IRCCS Policlin San Donato, Cardiol Dept, Milan, Italy
[4] Fdn Policlin Univ A Gemelli IRCCS, Cardiol Dept, Rome, Italy
[5] Hosp Univ Gran Canaria Dr Negrin, Cardiol Dept, Gran Canaria, Spain
[6] Kerckhoff Heart Ctr, Cardiol Dept, Bad Nauheim, Germany
[7] Ist Sci San Raffaele, Cardiol Dept, Milan, Italy
[8] Policlin Umberto 1, Cardiol Dept, Rome, Italy
[9] Hosp Santa Cruz, Cardiol Dept, Lisbon, Portugal
关键词
aortic stenosis; balloon-expandable; TAVR;
D O I
10.1002/ccd.29923
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives We aimed to describe hemodynamic performance and clinical outcomes at 30-day follow-up of the balloon-expandable (BE) Myval transcatheter heart valve (THV) in low-risk patients. Background The results of the next-generation BE Myval THV in low-risk aortic stenosis (AS) patients are still unknown. Methods Retrospective registry performed in nine European centers including patients with low predicted operative mortality risk according to Society of thoracic surgeons (STS) and European system for cardiac operative risk evaluation (EuroSCORE-II) scores. Results Between September 2019 and February 2021, a total of 100 patients (51% males, mean age 80 +/- 6.5 years) were included. Mean STS score and EuroSCORE-II were 2.4 +/- 0.8% and 2.2 +/- 0.7%, respectively. Intermediate sizes were used in 39% (21.5 mm: 8%, 24.5 mm: 15%, 27.5 mm: 15%). There were no cases of valve embolization, coronary artery occlusion, annulus rupture, or procedural death. A definitive pacemaker implantation was needed in eight patients (8%). At 30-day follow-up aortic valve area (0.7 +/- 0.2 vs. 2.1 +/- 0.6 cm(2)) and mean aortic valve gradient (43.4 +/- 11.1 vs. 9.0 +/- 3.7 mmHg) improved significantly (p < 0.001). Moderate aortic regurgitation occurred in 4%. Endpoints of early safety and clinical efficacy were 3 and 1%, respectively. Conclusions Hemodynamic performance and 30-day clinical outcomes of the BE Myval THV in low-risk AS patients were favorable. Longer-term follow-up is warranted.
引用
收藏
页码:889 / 895
页数:7
相关论文
共 50 条
  • [1] Multicenter Evaluation of a Next-Generation Balloon-Expandable Transcatheter Aortic Valve
    Webb, John
    Gerosa, Gino
    Lefevre, Thierry
    Leipsic, Jonathon
    Spence, Mark
    Thomas, Martyn
    Thielmann, Matthias
    Treede, Hendrik
    Wendler, Olaf
    Walther, Thomas
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (21) : 2235 - 2243
  • [2] Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients
    Mack, M. J.
    Leon, M. B.
    Thourani, V. H.
    Makkar, R.
    Kodali, S. K.
    Russo, M.
    Kapadia, S. R.
    Malaisrie, S. C.
    Cohen, D. J.
    Pibarot, P.
    Leipsic, J.
    Hahn, R. T.
    Blanke, P.
    Williams, M. R.
    McCabe, J. M.
    Brown, D. L.
    Babaliaros, V.
    Goldman, S.
    Szeto, W. Y.
    Genereux, P.
    Pershad, A.
    Pocock, S. J.
    Alu, M. C.
    Webb, J. G.
    Smith, C. R.
    NEW ENGLAND JOURNAL OF MEDICINE, 2019, 380 (18): : 1695 - 1705
  • [3] Early Outcomes of Transcatheter Aortic Valve Implantation With Next-generation Balloon-expandable Myval Transcatheter Heart Valve: Single-center Experience From Iraq
    Amber, Khalid
    Majeed, Ammar J.
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2024, 36 (01)
  • [4] Balloon-Expandable Transcatheter Heart Valve Geometry in Low-Risk Bicuspid Patients Undergoing Transcatheter Aortic Valve Replacement
    Medranda, Giorgio
    Rogers, Toby
    Case, Brian
    Ali, Syed
    Shea, Corey
    Zhang, Cheng
    Asch, Federico
    Weissman, Gaby
    Shults, Christian
    Garcia-Garcia, Hector
    Ben-Dor, Itsik
    Satler, Lowell
    Waksman, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 78 (19) : B153 - B154
  • [5] A novel balloon-expandable transcatheter aortic valve bioprosthesis: Myval and Myval Octacor
    Montonati, Carolina
    Pellegrini, Dario
    d'Atri, Daniele Oreste
    Pellicano, Mariano
    Briguglia, Daniele
    Giannini, Francesco
    De Blasio, Giuseppe
    Guagliumi, Giulio
    Tespili, Maurizio
    Ielasi, Alfonso
    EXPERT REVIEW OF CARDIOVASCULAR THERAPY, 2024, 22 (07) : 325 - 337
  • [6] Next-generation balloon-expandable transcatheter heart valve: the SAPIEN 3 Ultra valve
    Chatfield, Andrew
    Sathananthan, Janarthanan
    Wood, David A.
    Webb, John G.
    FUTURE CARDIOLOGY, 2021, 17 (05) : 811 - 816
  • [7] Balloon-Expandable Valve Geometry After Transcatheter Aortic Valve Replacement in Low-Risk Patients With Bicuspid Versus Tricuspid Aortic Stenosis
    Medranda, Giorgio A.
    Rogers, Toby
    Forrestal, Brian J.
    Case, Brian C.
    Yerasi, Charan
    Chezar-Azerrad, Chava
    Shults, Christian C.
    Torguson, Rebecca
    Shea, Corey
    Parikh, Puja
    Bilfinger, Thomas
    Cocke, Thomas
    Brizzio, Mariano E.
    Levitt, Robert
    Hahn, Chiwon
    Hanna, Nicholas
    Comas, George
    Mahoney, Paul
    Newton, Joseph
    Buchbinder, Maurice
    Zhang, Cheng
    Craig, Paige E.
    Weigold, W. Guy
    Asch, Federico M.
    Weissman, Gaby
    Garcia-Garcia, Hector M.
    Ben-Dor, Itsik
    Satler, Lowell F.
    Waksman, Ron
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2021, 33 : 7 - 12
  • [8] A Next-Generation Balloon-Expandable Transcatheter Aortic Valve First-in-Human Experience
    Meier, David
    Chatfield, Andrew G.
    Akodad, Mariama
    Jelisejevas, Julius
    Zaky, Fady
    Husain, Ali
    Blanke, Philipp
    Wood, David A.
    Sathananthan, Janarthanan
    Webb, John G.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2023, 16 (09) : 1125 - 1127
  • [9] Transcatheter aortic valve implantation using balloon-expandable Myval transcatheter heart valve in a patient with bicuspid aortic valve with low-flow, low-gradient severe aortic stenosis
    Adhikari, Chandra Mani
    Bogati, Amrit
    Timalsena, Birat Krishna
    Safi, Md. Sajjad
    Kharel, Sushant
    Thapa, Pratik
    Ghimire, Vijay
    Yadav, Rahul
    Khan, Barkadin
    Prajapati, Dipanker
    NEPALESE HEART JOURNAL, 2024, 21 (02) : 43 - 46
  • [10] Outcomes of Balloon-Expandable Transcatheter Aortic Valve Replacement in Younger Patients in the Low-Risk Era
    Coylewright, Megan
    Grubb, Kendra J.
    Arnold, Suzanne V.
    Batchelor, Wayne
    Dhoble, Abhijeet
    Horne, Aaron
    Leon, Martin B.
    Thourani, Vinod
    Nazif, Tamim M.
    Lindman, Brian R.
    Szerlip, Molly
    JAMA CARDIOLOGY, 2025, 10 (02) : 127 - 135