Parametric effect of vibrational drilling on osteonecrosis and comparative histopathology study with conventional drilling of cortical bone

被引:31
|
作者
Singh, Gurmeet [1 ]
Jain, Vivek [1 ]
Gupta, Dheeraj [1 ]
Sharma, Abhimanyu [2 ]
机构
[1] Deemed Be Univ, Thapar Inst Engn & Technol, Mech Engn Dept, Patiala 147004, Punjab, India
[2] Deemed Be Univ, Maharishi Markandeshwar Inst Med Sci & Res, Dept Pathol, Mullana, Ambala, India
关键词
Bone; bone fracture; bone drilling; osteonecrosis; histopathology; vibrational bone drilling; TAGUCHI METHOD; MEMBERSHIP FUNCTION; IN-VITRO; TEMPERATURE; OPTIMIZATION; HEAT; IRRIGATION; PERFORMANCE; QUALITY; FORCES;
D O I
10.1177/0954411918794983
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Drilling to the bones is required to re-fix them at their appropriate location using the implants. During drilling some thermal and mechanical losses may be faced by the bone and surrounding tissues which may lead to the serious issue in terms of osteonecrosis. Osteonecrosis is one of the reasons for impaired healing process for the fractured bone and causes further complications like low pullout strength of cortical screws and bone crush. In order to maintain the low temperature during bone drilling, this study focused the thermal damages observed by the bone and its surrounding during bone drilling and compared the results of conventional and vibrational drilling techniques. Parametric optimization under the influence of vibrations was also studied. Drilling has been done with the both drilling technique, and results were recorded in terms of temperature raise. Optimal solution for drilling the bone has been accessed using Taguchi optimization technique. The morphological comparison has been done for conventional and vibrational drilled holes using histopathology of drilled bones sections. From Taguchi optimization, it was observed that R1F1A1 is the parametric combination which gives minimum thermal injury to the bone in case of vibrational bone drilling. Analysis of variance cleared that the all parameters involved significantly affect the results (P0.05). Rotational speed was found to be the most influential factor among the all with 80.53%. Histopathology studies of bone specimens help to understand how heat generation affects the bone morphology during drilling. The specimens drilled with vibrational drilling show less damage in terms of osteonecrosis near the drill site which shows the significance of vibrational drilling in case of orthopedic surgeries. The raise in temperature during drilling is collective result of different drilling parameters. Vibrational drilling was observed a helping tool to control the thermal damage in bone drilling.
引用
下载
收藏
页码:975 / 986
页数:12
相关论文
共 50 条
  • [1] Cortical bone drilling and thermal osteonecrosis
    Augustin, Goran
    Zigman, Tomislav
    Davila, Slavko
    Udilljak, Toma
    Staroveski, Tomislav
    Brezak, Danko
    Babic, Slaven
    CLINICAL BIOMECHANICS, 2012, 27 (04) : 313 - 325
  • [2] Experimental Investigations on Microcracks in Vibrational and Conventional Drilling of Cortical Bone
    Wang, Yu
    Cao, Meng
    Zhao, Yuanyuan
    Zhou, Gang
    Liu, Wenyong
    Li, Deyu
    JOURNAL OF NANOMATERIALS, 2013, 2013
  • [3] In-vitro experimental study of histopathology of bone in vibrational drilling
    Alam, Khurshid
    Al-Ghaithi, Ahmed
    Piya, Sujan
    Saleem, Ashraf
    MEDICAL ENGINEERING & PHYSICS, 2019, 67 : 78 - 87
  • [4] Comparative statement for diametric delamination in drilling of cortical bone with conventional and ultrasonic assisted drilling techniques
    Singh, Gurmeet
    Babbar, Atul
    Jain, Vivek
    Gupta, Dheeraj
    JOURNAL OF ORTHOPAEDICS, 2021, 25 : 53 - 58
  • [5] Comparative study for surface topography of bone drilling using conventional drilling and loose abrasive machining
    Singh, Gurmeet
    Jain, Vivek
    Gupta, Dheeraj
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (03) : 225 - 231
  • [6] Comparative study of conventional and ultrasonically-assisted bone drilling
    Alam, K.
    Ahmed, Naseer
    Silberschmidt, V. V.
    TECHNOLOGY AND HEALTH CARE, 2014, 22 (02) : 253 - 262
  • [7] Experimental investigations and finite element simulation of cutting heat in vibrational and conventional drilling of cortical bone
    Wang, Yu
    Cao, Meng
    Zhao, Xiangrui
    Zhu, Gang
    McClean, Colin
    Zhao, Yuanyuan
    Fan, Yubo
    MEDICAL ENGINEERING & PHYSICS, 2014, 36 (11) : 1408 - 1415
  • [8] Investigation of the effect of movement and irrigation systems on temperature in the conventional drilling of cortical bone
    Alexandre Gehrke, Sergio
    Neto, Henrique Loffredo
    Mardegan, Fabio E. C.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2013, 51 (08): : 953 - 957
  • [9] Drilling of bone: thermal osteonecrosis regions induced by drilling parameters
    Akhbar, Mohd Faizal Ali
    Yusoff, Ahmad Razlan
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (06):
  • [10] Parametric study of bone drilling by the Kirschner wire
    Song, Shaokang
    Cheng, Xiang
    Li, Tao
    Shi, Ming
    Zheng, Guangming
    Liu, Huanbao