Accuracy validation for MRI-guided robotic prostate biopsy

被引:8
|
作者
Xu, Helen [1 ]
Lasso, Andras
Vikal, Siddharth
Guion, Peter [2 ]
Krieger, Axel [3 ]
Kaushal, Aradhana [2 ]
Whitcomb, Louis L. [4 ]
Fichtinger, Gabor [4 ]
机构
[1] Queens Univ, Sch Comp, Percutaneous Surg Lab, Perk Lab, Kingston, ON K7L 3N6, Canada
[2] NIH, Bethesda, MD 20892 USA
[3] Sentinelle Med Inc, Toronto, ON, Canada
[4] Johns Hopkins Univ, Baltimore, MD 21218 USA
关键词
Accuracy validation; image guided prostate biopsy; rigid volume registration; MRI; CANCER;
D O I
10.1117/12.844251
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report a quantitative evaluation of the clinical accuracy of a MRI-guided robotic prostate biopsy system that has been in use for over five years at the U. S. National Cancer Institute. A two-step rigid volume registration using mutual information between the pre and post needle insertion images was performed. Contour overlays of the prostate before and after registration were used to validate the registration. A total of 20 biopsies from 5 patients were evaluated. The maximum registration error was 2 mm. The mean biopsy target displacement, needle placement error, and biopsy error was 5.4 mm, 2.2 mm, and 5.1 mm respectively. The results show that the pre-planned biopsy target did dislocate during the procedure and therefore causing biopsy errors.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] MRI-Guided Robotic Prostate Biopsy: A Clinical Accuracy Validation
    Xu, Helen
    Lasso, Andras
    Vikal, Siddharth
    Guion, Peter
    Krieger, Axel
    Kaushal, Aradhana
    Whitcomb, Louis L.
    Fichtinger, Gabor
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT III, 2010, 6363 : 383 - +
  • [2] Accuracy analysis in MRI-guided robotic prostate biopsy
    Xu, Helen
    Lasso, Andras
    Guion, Peter
    Krieger, Axel
    Kaushal, Aradhana
    Singh, Anurag K.
    Pinto, Peter A.
    Coleman, Jonathan
    Grubb, Robert L., III
    Lattouf, Jean-Baptiste
    Menard, Cynthia
    Whitcomb, Louis L.
    Fichtinger, Gabor
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (06) : 937 - 944
  • [3] Accuracy analysis in MRI-guided robotic prostate biopsy
    Helen Xu
    Andras Lasso
    Peter Guion
    Axel Krieger
    Aradhana Kaushal
    Anurag K. Singh
    Peter A. Pinto
    Jonathan Coleman
    Robert L. Grubb
    Jean-Baptiste Lattouf
    Cynthia Menard
    Louis L. Whitcomb
    Gabor Fichtinger
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 937 - 944
  • [4] MRI-Guided Transrectal Robotic Prostate Biopsy Validation
    Xu, H.
    Lasso, A.
    Vikal, S.
    Guion, P.
    Krieger, A.
    Kaushal, A.
    Whitcomb, L.
    Fichtinger, G.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3128 - +
  • [5] MRI-guided and robotic-assisted prostate biopsy
    Futterer, Jurgen J.
    Barentsz, Jelle O.
    [J]. CURRENT OPINION IN UROLOGY, 2012, 22 (04) : 316 - 319
  • [6] Design of a MRI Viewer Software for MRI-guided Robotic Prostate Biopsy
    Moon, Hyojeong
    Kim, Dae Gwan
    Seung, Sungmin
    Lee, Hyunseok
    [J]. 2021 36TH INTERNATIONAL TECHNICAL CONFERENCE ON CIRCUITS/SYSTEMS, COMPUTERS AND COMMUNICATIONS (ITC-CSCC), 2021,
  • [7] A Fully Actuated Robotic Assistant for MRI-Guided Prostate Biopsy and Brachytherapy
    Li, Gang
    Su, Hao
    Shang, Weijian
    Tokuda, Junichi
    Hata, Nobuhiko
    Tempany, Clare M.
    Fischer, Gregory S.
    [J]. MEDICAL IMAGING 2013: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2013, 8671
  • [8] Target Motion Tracking in MRI-guided Transrectal Robotic Prostate Biopsy
    Tadayyon, Hadi
    Lasso, Andras
    Kaushal, Aradhana
    Guion, Peter
    Fichtinger, Gabor
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (11) : 3135 - 3142
  • [9] Accuracy study of a robotic system for MRI-guided prostate needle placement
    Seifabadi, Reza
    Cho, Nathan B. J.
    Song, Sang-Eun
    Tokuda, Junichi
    Hata, Nobuhiko
    Tempany, Clare M.
    Fichtinger, Gabor
    Iordachita, Iulian
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2013, 9 (03): : 305 - 316
  • [10] Biopsy Needle Artifact Localization in MRI-Guided Robotic Transrectal Prostate Intervention
    Song, Sang-Eun
    Cho, Nathan Bongjoon
    Iordachita, Iulian I.
    Guion, Peter
    Fichtinger, Gabor
    Kaushal, Aradhana
    Camphausen, Kevin
    Whitcomb, Louis L.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (07) : 1902 - 1911