Dead-Zone-Free Atomic Magnetometry with Simultaneous Excitation of Orientation and Alignment Resonances

被引:62
|
作者
Ben-Kish, A. [1 ]
Romalis, M. V. [1 ]
机构
[1] Princeton Univ, Dept Phys, Princeton, NJ 08544 USA
关键词
POLARIZATION-MODULATED LIGHT; PUMPED HE-4 MAGNETOMETER; MAGNETIC-FIELD; ISOTROPY; VAPOR;
D O I
10.1103/PhysRevLett.105.193601
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Atomic magnetometers have very high absolute precision and sensitivity to magnetic fields but suffer from a fundamental problem: the vectorial or tensorial interaction of light with atoms leads to "dead zones," certain orientations of the magnetic field where the magnetometer loses its sensitivity. We demonstrate a simple polarization modulation scheme that simultaneously creates coherent population trapping (CPT) in orientation and alignment, thereby eliminating dead zones. Using Rb-87 in a 10 Torr buffer gas cell we measure narrow, high-contrast CPT transparency peaks for all orientations and also show the absence of systematic effects associated with nonlinear Zeeman splitting.
引用
下载
收藏
页数:4
相关论文
共 24 条
  • [1] Light-Shift-Free and Dead-Zone-Free Atomic-Orientation-Based Scalar Magnetometry Using a Single Amplitude-Modulated Beam
    Yu, Q. -Q.
    Liu, S. -Q.
    Yuan, C. -Q.
    Sheng, D.
    PHYSICAL REVIEW APPLIED, 2022, 18 (01)
  • [2] Dead-zone-free atomic magnetometer based on hybrid Poincaré beams
    KE TIAN
    WEIFENG DING
    ZHAOYING WANG
    Photonics Research, 2024, 12 (05) : 1093 - 1097
  • [3] Dead-zone-free atomic magnetometer based on hybrid Poincaré beams
    Tian, Ke
    Ding, Weifeng
    Wang, Zhaoying
    PHOTONICS RESEARCH, 2024, 12 (05) : 1093 - 1097
  • [4] Motion noise reduction in drone magnetometry using a dead-zone-free total-field magnetometer system
    Zhang R.
    Hanselmann F.
    Fochs R.
    Lawrence M.
    Hurley K.
    Prouty M.
    Leading Edge, 2022, 41 (07): : 481 - 485
  • [5] Dual-Mode Dead-Zone-Free Double-Resonance Alignment-Based Magnetometer
    Wang, He
    Wu, Teng
    Xiao, Wei
    Wang, Haidong
    Peng, Xiang
    Guo, Hong
    PHYSICAL REVIEW APPLIED, 2021, 15 (02):
  • [6] Zero-field magnetometry based on the combination of atomic orientation and alignment
    Le Gal, Gwenael
    Palacios-Laloy, Agustin
    PHYSICAL REVIEW A, 2022, 105 (04)
  • [7] Dead-zone suppression method of NMOR atomic magnetometers based on alignment and orientation polarization
    Tian, Mengnan
    Jiang, Liwei
    Zhao, Xin
    Chai, Yanchao
    Liu, Jiali
    Lu, Zhenglong
    Quan, Wei
    SENSORS AND ACTUATORS A-PHYSICAL, 2024, 379
  • [8] A Dead-Zone-Free Zero Blind-Zone High-Speed Phase Frequency Detector for Charge-Pump PLL
    H. Lad Kirankumar
    S. Rekha
    Tonse Laxminidhi
    Circuits, Systems, and Signal Processing, 2020, 39 : 3819 - 3832
  • [9] A Dead-Zone-Free Zero Blind-Zone High-Speed Phase Frequency Detector for Charge-Pump PLL
    Kirankumar, H. Lad
    Rekha, S.
    Laxminidhi, Tonse
    CIRCUITS SYSTEMS AND SIGNAL PROCESSING, 2020, 39 (08) : 3819 - 3832
  • [10] OPTICAL ORIENTATION AND ALIGNMENT OF FREE EXCITONS IN GASE ON RESONANT EXCITATION EXPERIMENT
    GAMARTS, EM
    IVCHENKO, EL
    KARAMAN, MI
    MUSHINSKY, VP
    PIKUS, GE
    RAZBIRIN, BS
    STARUKHIN, AN
    ZHURNAL EKSPERIMENTALNOI I TEORETICHESKOI FIZIKI, 1977, 73 (03): : 1113 - 1128