X-ray computed tomography and thermal neutron radiography for detection of low dense compounds inside pyro elements used in space applications

被引:1
|
作者
Namboodiri, Girish N. [1 ,3 ]
Joseph, Manu [2 ]
Kumar, M. C. Santhosh [3 ]
Nallaperumal, M. [1 ]
Moideenkutty, K. K. [1 ]
Arumugam, M. [2 ]
Kumar, L. Mohan [1 ]
Jayaprakash, J. [1 ]
机构
[1] Vikram Sarabhai Space Ctr, Rocket Propellant Plant, Thiruvananthapuram 695022, Kerala, India
[2] Liquid Prop Syst Ctr, Thiruvananthapuram 695022, Kerala, India
[3] Natl Inst Technol, Tiruchirappalli 620015, Tamil Nadu, India
来源
EUROPEAN PHYSICAL JOURNAL PLUS | 2021年 / 136卷 / 09期
关键词
SYSTEM;
D O I
10.1140/epjp/s13360-021-01910-1
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Neutron radiography (NR) can be used for the detection and characterisation of explosives having different macroscopic attenuation cross sections. However, if the explosives have similar macroscopic cross sections to neutrons, characterising them is not possible. In this investigation, an attempt is made to distinguish various explosives based on the attenuation cross section of these compounds to neutrons. A correlation between the grey level achieved in neutron image of each explosive taken in a thin walled shell and their corresponding macroscopic attenuation cross section is carried out. An attempt is made to study the possibility of detection of some low dense compounds kept inside pyro metallic cases using cone beam X-ray 3D computed tomography. X-ray CT sliced images of samples filled with calcium carbonate and epoxy can be easily distinguished from empty samples. Samples were tested in NR and X-ray CT facility to compare the results. It is observed that low dense compounds of small volume positioned inside a bulk volume of SS metal of a pyro element used in this study are giving sufficient contrast that makes it detectable in CT cross-sectional image. The study points towards usage of X-ray CT as an alternative tool for detecting the presence of explosives in pyro devices wherever NR imaging cannot be carried out due to wall thickness constraints.
引用
收藏
页数:14
相关论文
共 23 条
  • [1] X-ray computed tomography and thermal neutron radiography for detection of low dense compounds inside pyro elements used in space applications
    Girish N. Namboodiri
    Manu Joseph
    M. C. Santhosh Kumar
    M. Nallaperumal
    K. K. Moideenkutty
    M. Arumugam
    L. Mohan Kumar
    J. Jayaprakash
    The European Physical Journal Plus, 136
  • [2] Detection and Characterisation of Low Dense Charges Inside Metallic Devices Used in Space Applications by Neutron Radiography
    Girish N. Namboodiri
    M. C. Santhosh Kumar
    M. Nallaperumal
    S. Umasankar
    G. Levin
    Journal of Nondestructive Evaluation, 2020, 39
  • [3] Detection and Characterisation of Low Dense Charges Inside Metallic Devices Used in Space Applications by Neutron Radiography
    Namboodiri, Girish N.
    Kumar, M. C. Santhosh
    Nallaperumal, M.
    Umasankar, S.
    Levin, G.
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2020, 39 (01)
  • [4] Neutron radiography and X-ray computed tomography for quantifying weathering and water uptake processes inside porous limestone used as building material
    Dewanckele, J.
    De Kock, T.
    Fronteau, G.
    Derluyn, H.
    Vontobel, P.
    Dierick, M.
    Van Hoorebeke, L.
    Jacobs, P.
    Cnudde, V.
    MATERIALS CHARACTERIZATION, 2014, 88 : 86 - 99
  • [5] Effects of microstructure on water imbibition in sandstones using X-ray computed tomography and neutron radiography
    Zhao, Yixin
    Xue, Shanbin
    Han, Songbai
    Chen, Zhongwei
    Liu, Shimin
    Elsworth, Derek
    He, Linfeng
    Cai, Jianchao
    Liu, Yuntao
    Chen, Dongfeng
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2017, 122 (07) : 4963 - 4981
  • [6] 'Applications of X-ray computed tomography in engineering geology' or 'looking inside rocks ...' Preface
    Jacobs, Patric
    Cnudde, Veerle
    ENGINEERING GEOLOGY, 2009, 103 (3-4) : 67 - 68
  • [7] Feasibility Studies on Explosive Detection and Homeland Security Applications Using a Neutron and X-ray Combined Computed Tomography System
    Sinha, V.
    Srivastava, A.
    Lee, H. K.
    Liu, X.
    CHEMICAL, BIOLOGICAL, RADIOLOGICAL, NUCLEAR, AND EXPLOSIVES (CBRNE) SENSING XIV, 2013, 8710
  • [8] Visualizing fluid transport inside orally disintegrating tablets and changes in tablets using real-time X-ray radiography and X-ray computed tomography
    Suzuki, Kazuhiro
    Yoshiki, Masahiko
    Nishikawa, Norio
    Harada, Tsutomu
    Fujita, Yoshiaki
    Terui, Yuji
    Yoshida, Takayuki
    Tomita, Takashi
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 2022, 48 (07) : 301 - 309
  • [9] Non-destructive investigation of aluminum alloy hemmed joints using neutron radiography and X-ray computed tomography
    Zheng, S.
    Vanderstelt, J.
    McDermid, J. R.
    Kish, J. R.
    NDT & E INTERNATIONAL, 2017, 91 : 32 - 35
  • [10] ASSESSMENT OF SURVEY RADIOGRAPHY AND COMPARISON WITH X-RAY COMPUTED-TOMOGRAPHY FOR DETECTION OF HYPERFUNCTIONING ADRENOCORTICAL TUMORS IN DOGS
    VOORHOUT, G
    STOLP, R
    RIJNBERK, A
    VANWAES, PFGM
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1990, 196 (11) : 1799 - 1803