Numerical Simulation of Axial-Flow Pump Cavitation Based on Variable Frequency Speed Regulation

被引:1
|
作者
Ye, Jincheng [1 ]
Tan, Linwei [1 ]
Shi, Weidong [1 ]
Chen, Cheng [1 ]
Francis, Egbo Munachi [1 ]
机构
[1] Nantong Univ, Sch Mech Engn, Nantong 226019, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
axial-flow pump; numerical simulation; variable voltage; variable frequency; cavitation performance;
D O I
10.3390/w14172757
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to investigate the influence of variable voltage and variable frequency (VVVF) regulation on the cavitation performance of the axial-flow pump, numerical simulation and experiments were used to analyze the cavitation performance of an axial-flow pump under different VVVF modes. The VVVF modes were uniform acceleration with constant acceleration, variable acceleration with increasing acceleration, variable acceleration with decreasing acceleration, and its corresponding deceleration scheme. Furthermore, a comprehensive performance test rig was built for the pump to carry out cavitation visualization tests which verified the accuracy of numerical simulation. For the uniform acceleration scheme with constant acceleration, the change of flow field inside the impeller was stable, the expansion rate of cavitation was slow, and the growth rate of the cavitation volume was the slowest. For the variable acceleration scheme with decreasing acceleration, the cavitation extended rapidly due to the large initial velocity. For the variable acceleration scheme with increasing acceleration, cavitation extension was the slowest. The growth rate of the cavity volume of the two variable acceleration schemes was faster than that of the uniform acceleration scheme, and the changing trend was consistent. This feature indicates that the impeller rotation speed has a significant impact on cavitation, and excessive rotation speed will rapidly extend the cavitation. By monitoring the influence of cavitation on pressure distribution under VVVF, it was shown that the three acceleration schemes all produce large pressure fluctuation. For the uniform acceleration scheme with constant acceleration, the fluctuation range of pressure was more balanced, and the pressure dropped slowly. For the acceleration scheme with higher acceleration, the pressure fluctuation amplitude increased in the late stage of acceleration and the pressure decline speed accelerated. For the acceleration scheme with decreasing acceleration, the pressure showed a downward trend with violent fluctuations in the early stage and gradually tended to be flat in the late stage.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] Numerical analysis of cavitation within slanted axial-flow pump
    张睿
    陈红勋
    JournalofHydrodynamics, 2013, 25 (05) : 663 - 672
  • [2] Numerical analysis of vortex and cavitation dynamics of an axial-flow pump
    Gong, Jie
    Luo, Wan-zhen
    Wu, Tie-cheng
    Zhang, Zhi-yuan
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2022, 16 (01) : 1921 - 1938
  • [3] Numerical analysis of cavitation within slanted axial-flow pump
    Rui Zhang
    Hong-xun Chen
    Journal of Hydrodynamics, 2013, 25 : 663 - 672
  • [5] CFD numerical simulation of sand-contained cavitation characteristics of axial-flow pump
    Lin, Peng
    Hu, Dong
    Lu, Jing-Man
    Wang, Shu
    ADVANCES IN MECHANICAL ENGINEERING, 2021, 13 (07)
  • [6] Numerical analysis of cavitation within slanted axial-flow pump
    Zhang Rui
    Chen Hong-xun
    JOURNAL OF HYDRODYNAMICS, 2013, 25 (05) : 663 - 672
  • [7] Experiments and numerical simulation on variable speed performance and internal flow of axial flow pump
    Sha, Yi
    Song, Deyu
    Duan, Fubin
    Yu, Caili
    Cao, Miaolong
    Jixie Gongcheng Xuebao/Journal of Mechanical Engineering, 2012, 48 (06): : 187 - 192
  • [8] Transient Characteristic Analysis of Variable Frequency Speed Regulation of Axial Flow Pump
    Zuo, Zilei
    Tan, Linwei
    Shi, Weidong
    Chen, Cheng
    Ye, Jincheng
    Francis, Egbo Munachi
    SUSTAINABILITY, 2022, 14 (18)
  • [9] Numerical simulation and experimental study of the interior flow in axial-flow pump
    Li, Zhong
    Yang, Min-Guan
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (11): : 1847 - 1850
  • [10] Numerical Simulation and Uncertainty Analysis of an Axial-Flow Waterjet Pump
    Qiu, Ji-Tao
    Yang, Chen-Jun
    Dong, Xiao-Qian
    Wang, Zong-Long
    Li, Wei
    Noblesse, Francis
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2018, 6 (02)