A gaussian model for scatter correction in myocardial SPECT.

被引:0
|
作者
Pettinato, C [1 ]
Marengo, M [1 ]
Guidalotti, P [1 ]
Gavaruzzi, G [1 ]
Fanti, S [1 ]
Civollani, S [1 ]
Pancaldi, D [1 ]
Bergamini, C [1 ]
机构
[1] Osped S Orsola Malpighi, Bologna, Italy
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
847
引用
收藏
页码:197P / 197P
页数:1
相关论文
共 50 条
  • [1] Scatter, attenuation and detector response correction in brain SPECT.
    Shinohara, H
    Matsuoka, M
    Yamamoto, T
    Niio, Y
    Kuniyasu, Y
    Hashimoto, T
    Takahashi, M
    Yokoi, T
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 302P - 302P
  • [2] Attenuation scatter correction decreases the false positive interpretation of myocardial ischemia: Stress gated SPECT.
    Heller, EN
    Kazzimudin, M
    Blum, S
    Alhaddad, IA
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 174P - 174P
  • [3] Effects of scatter and attenuation correction in quantitative rCBF studies with SPECT.
    Iida, H
    Kado, H
    Narita, Y
    Kashikura, A
    Eberl, S
    Kinoshita, T
    Ogawa, T
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1197 - 1197
  • [4] The relative importance of scatter and attenuation correction for quantitative brain SPECT.
    Stodilka, RZ
    Kemp, BJ
    Msaki, P
    Prato, FS
    Nicholson, RL
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 8P - 9P
  • [5] Effect of scatter correction on quantitative estimation in receptor ligand study with SPECT.
    Kim, KM
    Watabe, H
    Shidahara, M
    Varrone, A
    Fujita, M
    Innis, RB
    Iida, H
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 184P - 184P
  • [6] A computer simulation method for attenuation correction in myocardial SPECT.
    Shirakawa, S
    Yamaki, N
    Natsume, T
    Hasebe, S
    Toyama, H
    Maeda, H
    Takeda, K
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 275P - 275P
  • [7] Characterizing and correcting for scatter in brain SPECT.
    Kemp, BJ
    Ljungberg, M
    Stodilka, RZ
    Msaki, P
    Nicholson, RL
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 182P - 182P
  • [8] Validation and evaluation of model-based scatter and collimator-detector response compensation for myocardial SPECT.
    Frey, EC
    Song, XY
    Wang, WT
    Tocharoenchai, C
    Tsui, BMW
    Wilk, M
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 132P - 132P
  • [9] Effects of scatter correction on regional distribution of cerebral blood flow using SPECT.
    Ito, H
    Iida, H
    Kinoshita, T
    Hatazawa, J
    Okudera, T
    Uemura, K
    JOURNAL OF NUCLEAR MEDICINE, 1998, 39 (05) : 182P - 182P
  • [10] Effects of scatter and attenuation correction on quantitative analyses of beta-CIT Brain SPECT.
    Hashimoto, J
    Takatoku, K
    Bando, K
    Ogasawara, K
    Kubo, A
    Ogawa, K
    Motomura, N
    Ichihara, T
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 548 - 548