Characterization of a pixelated Cadmium-Zinc-Telluride detector for astrophysical application

被引:2
|
作者
Gaskin, JA [1 ]
Sharma, DP [1 ]
Ramsey, BD [1 ]
Mitchell, S [1 ]
Seller, P [1 ]
机构
[1] Univ Alabama, Dept Phys, Huntsville, AL 35899 USA
关键词
CdZnTe; X-ray detectors; pixel charge sharing;
D O I
10.1117/12.506369
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Charge sharing and charge loss measurements for a many-pixel, Cadmium-Zinc-Telluride (CdZnTe) detector are discussed. These properties that are set by the material characteristics and the detector geometry help to define the limiting energy resolution and spatial resolution of the detector in question. The detector consists of a 1-mm-thick piece of CdZnTe sputtered with a 16x16 array of pixels with a 300 micron pixel pitch (inter-pixel gap is 50 microns). This crystal is bonded to a custom-built readout chip (ASIC) providing all front-end electronics to each of the 256 independent pixels. These types of detectors act as precursors to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing degrades energy resolution through charge loss and improves spatial resolution through position interpolation.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 50 条
  • [1] A cadmium-zinc-telluride strip detector for high-energy diffraction applications
    Siddons, DP
    Camarda, G
    Kakuno, E
    SYNCHROTRON RADIATION INSTRUMENTATION, 2004, 705 : 965 - 968
  • [2] Characterisation of selected cadmium-zinc-telluride detectors
    Feichtinger, J
    Schröttner, T
    Schwaiger, M
    Kindl, P
    APPLIED RADIATION AND ISOTOPES, 2004, 61 (2-3) : 113 - 115
  • [3] A cadmium-zinc-telluride crystal array spectrometer
    Quam, W
    DeVore, T
    McHugh, H
    Vogle, R
    Wesolowski, J
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS V, 2004, 5198 : 26 - 34
  • [4] Application of cadmium-zinc-telluride detectors in 235U enrichment measurements
    Ruhter, W.D.
    Gunnink, R.
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 353 (1-3):
  • [5] Evaluation of a cadmium-zinc-telluride focal plane detector for hard X-ray astronomy
    Gaskin, JA
    Sharma, D
    Ramsey, B
    Seller, P
    RADIATION PHYSICS AND CHEMISTRY, 2004, 71 (3-4) : 731 - 732
  • [6] Characteristics of a 16x16 fine-pixel cadmium-zinc-telluride detector
    Sharma, DP
    Gaskin, JA
    Ramsey, BD
    Seller, P
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 1019 - 1028
  • [7] Charge sharing and charge loss in a cadmium-zinc-telluride fine-pixel detector array
    Gaskin, JA
    Sharma, DP
    Ramsey, BD
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 505 (1-2): : 122 - 125
  • [8] Development of a high spectral resolution cadmium zinc telluride pixel detector for astrophysical applications
    Harrison, FA
    Bolotnikov, A
    Chen, CMH
    Cook, WR
    Mao, PH
    Schindler, SM
    X-RAY AND GAMMA-RAY TELESCOPES AND INSTRUMENTS FOR ASTRONOMY, PTS 1 AND 2, 2003, 4851 : 823 - 830
  • [9] Preliminary results with a Cadmium-Zinc-Telluride gamma camera for scintimammography
    O'Connor, MK
    Rhodes, DJ
    Phillips, SW
    Collins, DA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S243 - S244
  • [10] Cadmium-Zinc-Telluride Myocardial Perfusion Imaging in Obese Patients
    Fiechter, Michael
    Gebhard, Catherine
    Fuchs, Tobias A.
    Ghadri, Jelena R.
    Stehli, Julia
    Kazakauskaite, Egle
    Herzog, Bernhard A.
    Pazhenkottil, Aju P.
    Gaemperli, Oliver
    Kaufmann, Philipp A.
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53 (09) : 1401 - 1406