Reduce Leakage Currents in Transformer less PVSystem Connected to Utility Grid with H-Bridge Inverter Topology

被引:0
|
作者
Jyothi, Boga [1 ,2 ]
Vinnakoti, Sudheer [3 ]
Varaprasad, Madisa V. G. [1 ]
机构
[1] Vignans Inst Informat Technol, Visakhapatnam, Andhra Pradesh, India
[2] Koneru Lakshmaiah Educ Fdn, Vijayawada, Andhra Pradesh, India
[3] RAGHU Engn Coll, Visakhapatnam, Andhra Pradesh, India
关键词
solar energy; Maximum power point tracking; H-Bridge inverter; Bi-polar PWM; LCL Filter topology;
D O I
10.1109/ICAECT54875.2022.9807952
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Renewable energy is becoming a necessity as alternative forms of energy generation are needed to meet the world's energy demands. In this report, the three main current PV system configurations will be discussed and compared in terms of cost, reliability and performance. There are different topologies introduced in grid connected pv system with transformer and transformer less. There exist transformer between pv array and grid in previously so there exist galvanic isolation. The main problem with using transformer resonance due to thus transformer and harmonics injected in grid because of these DC spillage current infused into the network may cause saturation of core in transformer at distribution side and it cause overheating and failure. Stray capacitance in between pv array and ground the spillage current flow through this. Different inverter topologies reduce leakage currents that are half-bridge and full- bridge topologies, with bipolar pulse width modulation have been proposed. In this project proposed high- efficient topology these generate no common varying mode voltage and require low input voltage as bipolar pwm full bridge. In these bipolar pwm with using LCL filter topology is used to reduce leakage currents between PV array and grid. In these DC-AC inverter displayed with H-Bridge protected Gate Bipolar Semiconductor module which is controlled utilizing bipolar PWM strategy. There using the MPPT Technique of perturb and observe to absorb maximum amount of power from PV system. In these PLL is utilize to keep up synchronize the voltage, current, frequency in phase with the grid. These current and voltage regulators are used to analyze the reference voltage is acquired from the inverter active current and reactive current is zero.By using PI and FUZZY current controller to reduce total harmonic distortion with using fuzzy current controller is better than PI to improve power quality.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Common Mode Leakage Current Analysis of 1-Φ Grid-Tied Transformer Less H-Bridge PV Inverter
    Srivastava, Ankur
    Seshadrinath, Jeevanand
    [J]. 2021 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND FUTURE ELECTRIC TRANSPORTATION (SEFET), 2021,
  • [2] Transformer-less Grid-connected Inverter With Low Leakage Currents for Photovoltaic Generation System
    Liu, Bangyin
    Zeng, Zhaosong
    Wei, Qikang
    Duan, Shanxu
    [J]. 2015 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2015, : 4563 - 4567
  • [3] Grid connected asymmetric cascaded H-bridge with LDN topology
    Sharma, Deepak
    Kumar, Ujwal
    Shetty, Kajal K.
    Kasari, Prabir Ranjan
    Chakrabarti, Abanishwar
    Das, Bikram
    [J]. 2019 INNOVATIONS IN POWER AND ADVANCED COMPUTING TECHNOLOGIES (I-PACT), 2019,
  • [4] Cascaded H-Bridge Multilevel PV Inverter With MPPT For Grid Connected Application
    Katkamwar, Sonam S.
    Doifode, V. R.
    [J]. 2016 INTERNATIONAL CONFERENCE ON ENERGY EFFICIENT TECHNOLOGIES FOR SUSTAINABILITY (ICEETS), 2016, : 641 - 646
  • [5] Bifurcation Analysis in a Digitally Controlled H-Bridge Grid-Connected Inverter
    Lei, Bo
    Xiao, Guochun
    Wu, Xuanlv
    Kafle, Yuba-Raj
    Zheng, Lifu
    [J]. INTERNATIONAL JOURNAL OF BIFURCATION AND CHAOS, 2014, 24 (01):
  • [6] Grid-Connected Photovoltaic System Based on a Cascaded H-Bridge Inverter
    Rezaei, Mohammad-Ali
    Iman-Eini, Hossein
    Farhangi, Shahrokh
    [J]. JOURNAL OF POWER ELECTRONICS, 2012, 12 (04) : 578 - 586
  • [7] Three-Phase Transformerless Grid-Connected Photovoltaic Inverter to Reduce Leakage Currents
    Freddy, Tan Kheng Suan
    Abd Rahim, Nasrudin
    Ping, Hew Wooi
    [J]. 2013 IEEE CONFERENCE ON CLEAN ENERGY AND TECHNOLOGY (CEAT), 2013, : 277 - 280
  • [8] Simple Technique Reducing Leakage Current for H-Bridge Converter in Transformer less Photovoltaic Generation
    Kot, Radoslaw
    Stynski, Sebastian
    Stepien, Krzysztof
    Zaleski, Jaroslaw
    Malinowski, Mariusz
    [J]. JOURNAL OF POWER ELECTRONICS, 2016, 16 (01) : 153 - 162
  • [9] Leakage current analysis of a single-phase transformer-less PV inverter connected to the grid
    Ma, Lin
    Tang, Fen
    Zhou, Fei
    Jin, Xinmin
    Tong, Yibin
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 285 - +
  • [10] Stable Operation of Grid Connected Cascaded H-Bridge Inverter under Unbalanced Insolation Conditions
    Eskandari, Abbas
    Javadian, Vahid
    Iman-Eini, Hossein
    Yadollahi, Milad
    [J]. 2013 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2013,