Heart Rate Monitoring With Smartphone Built-In Frontal Digital Camera

被引:1
|
作者
Molinaro, Nunzia [1 ]
Schena, Emiliano [1 ]
Silvestri, Sergio [1 ]
Massaroni, Carlo [1 ]
机构
[1] Univ Campus Biomed Roma, Unit Measurements & Biomed Instrumentat, Dept Engn, Rome, Italy
关键词
non-contact monitoring; smartphone's camera; unobtrusive monitoring; heart rate estimation; NONCONTACT;
D O I
10.1109/MetroInd4.0IoT54413.2022.9831498
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Non-contact technologies are gaining much interest as promising systems for remote monitoring of physiological parameters (e.g., heart rate -HR-, respiratory rate, blood pressure, blood oxygen saturation) without interfering with the subject's comfort. Among the existing technologies, digital cameras integrated into smartphones or laptops are widely used due to their ease of use, availability, and portability. In this study, we investigated the influence of distance on the HR estimation from a video recorded with a smartphone's frontal camera. HR values were provided from a spectral analysis every 1 s. We evaluated the performances of six different algorithms to identify the best one for HR estimation simulating an occupational scenario at two distances (i.e., 0.5 m and 1 m). Data were recorded from 8 healthy volunteers of both sexes; a wearable device was used to record medical-grade ECG to estimate reference HR values. Results show that the higher the camera distance, the higher the mean absolute error (MAE): the average MAE was 1.49 bpm at 0.5 m and 2.59 bpm at 1.0 m. Moreover, Green Channel, Chrominance-based signal processing method (CHROM), and Plane Orthogonal to Skin (POS) have been identified as the best algorithms to estimate HR since they showed a better agreement with the reference system than the other algorithms.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 50 条
  • [1] Validation of heart rate extraction using video imaging on a built-in camera system of a smartphone
    Kwon, Sungjun
    Kim, Hyunseok
    Park, Kwang Suk
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2174 - 2177
  • [2] Seismo: Blood Pressure Monitoring using Built-in Smartphone Accelerometer and Camera
    Wang, Edward Jay
    Zhu, Junyi
    Jain, Mohit
    Lee, Tien-Jui
    Saba, Elliot
    Nachman, Lama
    Patel, Shwetak N.
    [J]. PROCEEDINGS OF THE 2018 CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS (CHI 2018), 2018,
  • [3] ABC: Enabling Smartphone Authentication with Built-in Camera
    Ba, Zhongjie
    Piao, Sixu
    Fu, Xinwen
    Koutsonikolas, Dimitrios
    Mohaisen, Aziz
    Ren, Kui
    [J]. 25TH ANNUAL NETWORK AND DISTRIBUTED SYSTEM SECURITY SYMPOSIUM (NDSS 2018), 2018,
  • [4] Instantaneous heart rate estimation based on the built-in multisensor of an Android smartphone
    Li X.
    Pu B.
    Yang D.
    Yu X.
    Wang S.
    [J]. Harbin Gongcheng Daxue Xuebao/Journal of Harbin Engineering University, 2018, 39 (04): : 730 - 735
  • [5] Instantaneous Heart Rate Detection using Smart Phones Built-in Camera
    Li, Han
    Zhao, Hai
    [J]. PROCEEDINGS OF THE 2016 2ND WORKSHOP ON ADVANCED RESEARCH AND TECHNOLOGY IN INDUSTRY APPLICATIONS, 2016, 81 : 1618 - 1623
  • [6] Digital camera with built-in printer looms on the horizon
    Eccles, L
    [J]. ELECTRONIC DESIGN, 2001, 49 (02) : 36 - 36
  • [7] Smartphone Input Using Its Integrated Projector and Built-In Camera
    Dotenco, Sergiu
    Goetzelmann, Timo
    Gallwitz, Florian
    [J]. HUMAN-COMPUTER INTERACTION: APPLICATIONS AND SERVICES, PT III, 2014, 8512 : 124 - 133
  • [8] Application for Determining the Modulation Transfer Function of the Smartphone Built-in Camera
    Perezyabov, Oleg. A.
    Baranov, Aleksandr N.
    Maltseva, Nadezhda K.
    Ilinski, Aleksandr V.
    [J]. 2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - SPRING (PIERS), 2017, : 3804 - 3808
  • [9] A Wearable Device for Physical Activity Monitoring With Built-in Heart Rate Variability
    Dinh, Anh
    Teng, Daniel
    Chen, Li
    Ko, Seok-Bum
    Shi, Yang
    McCrosky, Carl
    Basran, Jenny
    Del Bello-Hass, Vanina
    [J]. 2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 1272 - 1275
  • [10] A Proposal of Eye Glance Input Interface using Smartphone Built-in Camera
    スマートフォン内蔵カメラを用いた Eye Glance 入力インタフェースの検討
    [J]. Saiga, Yu (yusaiga@uec.ac.jp), 1600, Institute of Electrical Engineers of Japan (141): : 650 - 656