Intrapleural Impedance Sensor Real-Time Tracking of Pneumothorax in a Porcine Model of Air Leak

被引:4
|
作者
DeArmond, Daniel T. [1 ]
Das, Nitin A. [1 ]
Restrepo, Carlos S. [2 ]
Katona, Mitch A. [1 ]
Johnson, Scott B. [1 ]
Hernandez, Brian S. [3 ]
Michalek, Joel E. [3 ]
机构
[1] Univ Texas Hlth Sci Ctr San Antonio UTHSCSA, Dept Cardiothorac Surg, 7703 Floyd Curl Dr, San Antonio, TX 78229 USA
[2] UTHSCSA, Dept Radiol, San Antonio, TX USA
[3] UTHSCSA, Dept Epidemiol & Biostat, San Antonio, TX USA
关键词
Pneumothorax; Electrical impedance; Chest tubes; Pulmonary surgical procedures; Lung injury; PROSPECTIVE RANDOMIZED-TRIAL; WATER SEAL; TENSION PNEUMOTHORAX; ELECTRICAL-IMPEDANCE; PULMONARY RESECTION; SUCTION; DRAINAGE; THORACOSTOMY; LOBECTOMY;
D O I
10.1053/j.semtcvs.2019.10.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In patients with alveolar-to-pleural air leak due to recent surgery or trauma, clinicians tend to manage chest tubes with suction therapy. Nonsuction therapy is associated with shorter chest tube duration but also a higher risk of pneumothorax. We sought to develop an intrapleural electrical impedance sensor for continuous, real-time monitoring of pneumothorax development in a porcine model of air leak as a means of promoting nonsuction therapy. Using thoracoscopy, 2 chest tubes and the pleural impedance sensor were introduced into the pleural space of 3 pigs. Continuous air leak was introduced through 1 chest tube by carbon dioxide insufflation. The second chest tube was placed to suction then transitioned to no suction at increasingly higher air leaks until pneumothorax developed. Simultaneously, real-time impedance measurements were obtained from the pleural sensor. Fluoroscopy spot images were captured to verify the presence or absence of pneumothorax. Statistical Analysis Software was used throughout. With the chest tube on suction, a fully expanded lung was identified by a distinct pleural electrical impedance respiratory waveform. With transition of the chest tube to water seal, loss of contact of the sensor with the lung resulted in an immediate measurement of infinite electrical impedance. Pneumothorax resolution by restoring suction therapy was detected in real time by a return of the normal respiratory impedance waveform. Pleural electrical impedance monitoring detected pneumothorax development and resolution in real time. This simple technology has the potential to improve the safety and quality of chest tube management. © 2019 Elsevier Inc.
引用
收藏
页码:357 / 366
页数:10
相关论文
共 50 条
  • [1] INTRAPLEURAL QUINACRINE INSTILLATION FOR RECURRENT PNEUMOTHORAX OR PERSISTENT AIR LEAK
    JANZING, HMJ
    DEROM, A
    DEROM, E
    EECKHOUT, C
    DEROM, F
    ROSSEEL, MT
    TYERS, GFO
    [J]. ANNALS OF THORACIC SURGERY, 1993, 55 (02): : 368 - 371
  • [2] REAL-TIME TRANSIENT MODEL FOR BATCH TRACKING, LINE BALANCE AND LEAK DETECTION
    HUBER, DW
    [J]. JOURNAL OF CANADIAN PETROLEUM TECHNOLOGY, 1981, 20 (03): : 46 - 52
  • [3] Real-time detection of pneumothorax using electrical impedance tomogyaphy
    Costa, Eduardo L. V.
    Chaves, Caroline N.
    Gomes, Susimeire
    Beraldo, Marcelo A.
    Volpe, Marcia S.
    Tucci, Mauro R.
    Schettino, Lvany A. L.
    Bohm, Stephan H.
    Carvalho, Carlos R. R.
    Tanaka, Harki
    Lima, Raul G.
    Amato, Marcelo B. P.
    [J]. CRITICAL CARE MEDICINE, 2008, 36 (04) : 1230 - 1238
  • [4] Pleural electrical impedance is a sensitive, real-time indicator of pneumothorax
    DeArmond, Daniel T.
    Das, Nitin A.
    Restrepo, Carlos S.
    Johnson, Scott B.
    Michalek, Joel E.
    Hernandez, Brian S.
    [J]. JOURNAL OF SURGICAL RESEARCH, 2018, 231 : 15 - 23
  • [5] Intrapleural instillation of autologous blood for persistent air leak in spontaneous pneumothorax- is it as effective as it is safe?
    Dimos Karangelis
    Georgios I Tagarakis
    Marios Daskalopoulos
    Georgios Skoumis
    Nicholaos Desimonas
    Vasileios Saleptsis
    Theocharis Koufakis
    Athanasios Drakos
    Dimitrios Papadopoulos
    Nikolaos B Tsilimingas
    [J]. Journal of Cardiothoracic Surgery, 5
  • [6] A SMART PROCESSOR ARRAY SENSOR FOR REAL-TIME TRACKING
    COQUELET, C
    DEVOS, F
    GARDA, P
    [J]. ONDE ELECTRIQUE, 1988, 68 (06): : 82 - 85
  • [7] A switchable peptide sensor for real-time lysosomal tracking
    Chen, Lei
    Wu, Junchen
    Schmuck, Carsten
    Tian, He
    [J]. CHEMICAL COMMUNICATIONS, 2014, 50 (49) : 6443 - 6446
  • [8] A Multi Sensor Real-time Tracking with LiDAR and Camera
    Manghat, Surya Kollazhi
    El-Sharkawy, Mohamed
    [J]. 2020 10TH ANNUAL COMPUTING AND COMMUNICATION WORKSHOP AND CONFERENCE (CCWC), 2020, : 668 - 672
  • [9] Real-Time Object Tracking in Wireless Sensor Network
    Abid, Anam
    Khan, Faizan
    Hayat, Mahnoor
    Khan, Waheed
    [J]. 2017 10TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO), 2017, : 1103 - 1107
  • [10] Multi-sensor fusion for real-time object tracking
    Verma, Sakshi
    Singh, Vishal K. K.
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2024, 83 (07) : 19563 - 19585