Semi-automated IGRT QA using a cone-shaped scintillator screen detector for proton pencil beam scanning treatments

被引:13
|
作者
Cai, Weixing [1 ,2 ,3 ,4 ,5 ]
Oesten, Hakan [2 ,3 ,6 ,7 ,8 ]
Clasie, Benjamin [2 ,3 ]
Winey, Brian [2 ,3 ]
Jee, Kyung-Wook [2 ,3 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, 500 Westchester Ave, White Plains, NY 10604 USA
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, 55 Fruit St, Boston, MA 02114 USA
[3] Harvard Med Sch, 55 Fruit St, Boston, MA 02114 USA
[4] Brigham & Womens Hosp, Dept Radiat Oncol, 75 Francis St, Boston, MA 02115 USA
[5] Harvard Med Sch, 75 Francis St, Boston, MA 02115 USA
[6] HZDR, Inst Radiooncol OncoRay, Dresden, Germany
[7] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Fac Med, Dresden, Germany
[8] Tech Univ Dresden, Helmholtz Zentrum Dresden Rossendorf, Univ Hosp Carl Gustav Carus, OncoRay Natl Ctr Radiat Res Oncol, Dresden, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2019年 / 64卷 / 08期
关键词
proton therapy; pencil beam scanning; quality assurance; image-guided radiation therapy; THERAPY; SYSTEM; ACCELERATOR;
D O I
10.1088/1361-6560/ab056d
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To promote accurate image-guided radiotherapy (IGRT) for a proton pencil beam scanning (PBS) system, a new quality assurance (QA) procedure employing a cone-shaped scintillator detector has been developed for multiple QA tasks in a semi-automatic manner. The cone-shaped scintillator detector (XRV-124, Logos Systems, CA) is sensitive to both x-ray and proton beams. It records scintillation on the cone surface as a 2D image, from which the geometry of the radiation field that enters and exits the cone can be extracted. Utilizing this feature, QA parameters that are essential to PBS IGRT treatment were measured and analyzed. The first applications provided coincidence checks of laser, imaging and radiation isocenters, and dependencies on gantry angle and beam energies. The analysis of the Winston-Lutz test was made available by combining the centricity measurements of the x-ray beam and the pencil beam. The accuracy of the gantry angle was validated against console readings provided by the digital encoder and an agreement of less than 0.2 was found. The accuracy of the position measurement was assessed with a robotic patient positioning system (PPS) and an agreement of less than 0.5 mm was obtained. The centricity of the two onboard x-ray imaging systems agreed well with that from the routinely used Digital Imaging Positioning System (DIPS), up to a consistent small shift of (-0.5 mm, 0.0 mm, -0.3 mm). The pencil beam spot size, in terms of a of Gaussian fitting, agreed within 0.2 mm for most energies when compared to the conventional measurements by a 2D ion-chamber array (MatriXX-PT, IBA Dosimetry, Belgium). The cone-shaped scintillator system showed advantages in making multi-purpose measurements with a single setup. The in-house algorithms were successfully implemented to measure and analyze key QA parameters in a semi-automatic manner. This study presents an alternative and more efficient approach for IGRT QA for PBS and potentially for linear accelerators.
引用
收藏
页数:10
相关论文
共 20 条
  • [1] Semi-Automated IGRT QA Using a Cone-Shaped Scintillator Screen Detector for Proton Pencil Beam Scanning Treatments
    Cai, W.
    Oesten, H.
    Clasie, B.
    Winey, B.
    Jee, K.
    MEDICAL PHYSICS, 2017, 44 (06) : 3055 - 3056
  • [2] A Cone-Based Scintillator Detector for IGRT QA for Scattered and Scanning Proton Therapy
    Oesten, H.
    Clasie, B.
    Nelson, B.
    Jee, K.
    MEDICAL PHYSICS, 2016, 43 (06) : 3417 - 3417
  • [3] Application of cone-shaped scintillation detector for quality assurance in pencil beam scanning proton therapy systems
    Lingjing, Pan
    Xianbao, Gu
    Yuanyuan, Wang
    Yangfan, Zhang
    Xiaoming, Lu
    Zhipeng, Liu
    He Jishu/Nuclear Techniques, 2024, 47 (08):
  • [4] End-to-end test to evaluate the comprehensive geometric accuracy of a proton rotating gantry using a cone-shaped scintillator screen detector
    Takahiro Kato
    Yuhei Yamazaki
    Ryohei Kato
    Shinya Komori
    Hiromitsu Endo
    Sho Oyama
    Tatsuhiko Sagara
    Radiological Physics and Technology, 2020, 13 : 144 - 151
  • [5] End-to-end test to evaluate the comprehensive geometric accuracy of a proton rotating gantry using a cone-shaped scintillator screen detector
    Kato, Takahiro
    Yamazaki, Yuhei
    Kato, Ryohei
    Komori, Shinya
    Endo, Hiromitsu
    Oyama, Sho
    Sagara, Tatsuhiko
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2020, 13 (02) : 144 - 151
  • [6] An Automated Monte Carlo Based QA Framework for Pencil Beam Scanning Treatments
    Shin, J.
    Jee, K.
    Clasie, B.
    Depauw, N.
    Madden, T.
    Sharp, G.
    Paganetti, H.
    Kooy, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3685 - 3685
  • [7] A gas scintillator detector for 2D dose profile monitoring in pencil beam scanning and pulsed beam proton radiotherapy treatments
    Vigdor, S. E.
    Klyachko, A. V.
    Solberg, K. A.
    Pankuch, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (12): : 4946 - 4969
  • [8] Comparison of visual and semi-automated kilovoltage cone beam CT image QA analysis
    Becerra-Espinosa, Nicholas
    Claps, Lindsey
    Alaei, Parham
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (02):
  • [9] Initial Experience of Patient-Specific QA Using a Pencil Beam Scanning Proton Therapy System
    Piskulich, F.
    Zhang, Y.
    Perles, L.
    Mascia, A.
    Lepage, R.
    Giebeler, A.
    Dong, L.
    MEDICAL PHYSICS, 2014, 41 (06) : 384 - 384
  • [10] Proton range assessment using prompt gamma monitoring of realistic pencil beam scanning treatments
    Janssens, G.
    Smeets, J.
    Stappen, F. Vander
    Prieels, D.
    Perali, I.
    Clementel, E.
    Hotoiu, L.
    Sterpin, E.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S180 - S181