Chronotropic Incompetence and Abnormal Heart Rate Recovery Early after Left Ventricular Assist Device Implantation

被引:37
|
作者
Dimopoulos, Stavros [1 ]
Diakos, Nikolaos [2 ,3 ]
Tseliou, Eleni [2 ,3 ]
Tasoulis, Athanasios [1 ]
Mpouchla, Anthi [1 ]
Manetos, Christos [1 ]
Katsaros, Lambros [2 ,3 ]
Drakos, Stavros [2 ,3 ,4 ]
Terrovitis, John [2 ,3 ]
Nanas, Serafim [1 ]
机构
[1] Natl & Kapodestrian Univ Athens, Cardiopulm Exercise Testing & Rehabil Lab, Crit Care Med Dept 1, Athens 10675, Greece
[2] Natl & Kapodestrian Univ Athens, Cardiol Dept 3, Athens 10675, Greece
[3] Natl & Kapodestrian Univ Athens, Dept Clin Therapeut, Athens 10675, Greece
[4] Univ Utah, Div Cardiol, Salt Lake City, UT 84112 USA
来源
关键词
LVAD; heart rate recovery; chronotropic reserve; autonomic nervous system; continuous-flow LVAD; SYMPATHETIC ACTIVATION; ANAEROBIC THRESHOLD; PROGNOSTIC VALUE; BETA-BLOCKADE; GAS-EXCHANGE; FAILURE; EXERCISE; SUPPORT; MYOCARDIUM; MODULATION;
D O I
10.1111/j.1540-8159.2011.03215.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Chronotropic response to exercise and heart rate recovery immediately after exercise (HRR1) are valid prognostic markers in patients with chronic heart failure (CHF). The aim of this study was to evaluate heart rate profile during and after exercise in CHF patients early after left ventricular assist device (LVAD) implantation. Methods: We enrolled seven stable consecutive CHF patients (five males, mean age: 45 +/- 16 years) after 1 month of LVAD (HeartMate II; Thoratec Corp, Pleasanton, CA, USA) implantation, seven healthy subjects, and 14 patients with advanced HF (HF control group) who performed an incremental symptomlimited cardiopulmonary exercise testing (CPET). CHF patients performed CPET at 1 and 3 months after LVAD. HRR1 was defined as the HR difference from peak to 1 minute after exercise and chronotropic response to exercise as the chronotropic reserve ([CR, %] = [peak HR-resting HR/220-age-resting HR] x 100). Results: LVAD patients 3 months after implantation had a significantly different HR profile during exercise compared to healthy controls, with significantly lower CR (57 +/- 31 vs 90 +/- 14, %, P < 0.001) and HRR1 (14 +/- 6 vs 28 +/- 8, bpm, P < 0.01). HR profile during exercise did not significantly change 1 and 3 months after LVAD implantation. There was no statistical difference compared to HF control group and LVAD group regarding cardiopulmonary parameters. Conclusions: LVAD patients present an impaired CR and an abnormal HRR1 after implantation, indicating significant cardiac autonomic abnormalities. These alterations seem to remain unaltered 3 months after LVAD implantation. (PACE 2011; 34: 1607-1614)
引用
收藏
页码:1607 / 1614
页数:8
相关论文
共 50 条
  • [1] Abnormal hemodynamics cause chronotropic incompetence and slowed heart rate recovery after exercise
    Skaluba, SJ
    Briggs, JE
    Briggs, JE
    Litwin, SE
    CIRCULATION, 2003, 108 (17) : 700 - 700
  • [2] Early Ventricular Arrhythmias After Left Ventricular Assist Device Implantation
    Oates, Connor P.
    Lam, Phillip H.
    Lawrence, Luke
    Bigham, Grace
    Meda, Namratha S.
    Basyal, Binaya
    Hadadi, Cyrus A.
    Rao, Sriram D.
    Hockstein, Michael
    Shah, Manish
    Sheikh, Farooq H.
    JOURNAL OF CARDIAC FAILURE, 2024, 30 (08) : 1018 - 1027
  • [3] Right heart failure after left ventricular assist device implantation: early and late
    MacGowan, Guy A.
    Schueler, Stephan
    CURRENT OPINION IN CARDIOLOGY, 2012, 27 (03) : 296 - 300
  • [4] Association of abnormal heart rate recovery and chronotropic incompetence with obesity in a healthy cohort
    Lauer, MS
    Yu, D
    Pothier, CE
    Blackstone, EH
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 191A - 192A
  • [5] Early stroke after left ventricular assist device implantation: role of right heart failure
    Park, Ilkun
    Yang, Jeong Hoon
    Kim, Darae
    Choi, Jin-Oh
    Jeon, Eun-Seok
    Sung, Kiick
    Kim, Wook Sung
    Cho, Yang Hyun
    JOURNAL OF THORACIC DISEASE, 2023, 15 (12) : 6730 - 6740
  • [6] Predictors for Early and Late Right Heart Failure After Left Ventricular Assist Device Implantation
    Stendardi, W. F.
    Braun, O. O.
    Brambatti, M.
    Kim, P.
    Pretorius, V.
    Tran, H.
    Greenberg, B.
    Adler, E.
    Enciso, J. S.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2018, 37 (04): : S374 - S374
  • [7] Risk of stroke early after implantation of a left ventricular assist device
    Samura, Takaaki
    Yoshioka, Daisuke
    Toda, Koichi
    Sakaniwa, Ryoto
    Shimizu, Mikito
    Miyagawa, Shigeru
    Yoshikawa, Yasushi
    Hata, Hiroki
    Saito, Shunsuke
    Sakata, Yasushi
    Sawa, Yoshiki
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (01): : 259 - +
  • [8] Skeletal Muscle Mass Recovery Early After Left Ventricular Assist Device Implantation in Patients With Advanced Systolic Heart Failure
    Vest, Amanda R.
    Chery, Joronia
    Coston, Alexandra
    Telfer, Laura
    Lawrence, Matthew
    Haynes, Abbey
    Karanja, Pascaline
    Singla, Arnav
    Kiernan, Michael S.
    Couper, Gregory
    Saltzman, Edward
    CIRCULATION, 2020, 142
  • [9] Skeletal Muscle Mass Recovery Early After Left Ventricular Assist Device Implantation in Patients With Advanced Systolic Heart Failure
    Vest, Amanda R.
    Chery, Joronia
    Telfer, Laura
    Lawrence, Matthew
    Kiernan, Michael S.
    Couper, Gregory
    Saltzman, Edward
    Celkupa, Didjana
    Kawaborie, Masashi
    Wong, William W.
    Coston, Alex
    CIRCULATION-HEART FAILURE, 2022, 15 (05) : 433 - 442
  • [10] Renal Recovery after Implantation of a Left Ventricular Assist Device: "The "Hibernating Kidney"
    Sarswat, Nitasha
    Zolty, Ronald
    Maybaum, Simon
    Vittorio, Timothy J.
    JOURNAL OF CARDIAC FAILURE, 2009, 15 (06) : S46 - S46