Effects of flow patterns and salinity on water holdup measurement of oil-water two-phase flow using a conductance method

被引:33
|
作者
Liu, W. X. [1 ,2 ]
Jin, N. D. [1 ]
Han, Y. F. [1 ]
Zhai, L. S. [1 ]
Chen, X. [1 ]
Zhang, H. X. [1 ]
机构
[1] Tianjin Univ, Sch Elect Engn & Automat, Tianjin 300072, Peoples R China
[2] Tianjin Polytech Univ, Sch Comp Sci & Software Engn, Tianjin 300387, Peoples R China
基金
中国国家自然科学基金;
关键词
Oil-water two-phase flow; Flow pattern; Water holdup; Salinity; Conductance sensor; LIQUID FLOWS; PROBE ARRAY; SENSOR; FRACTION; SPECTROSCOPY; PARAMETERS;
D O I
10.1016/j.measurement.2016.07.053
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This research investigates the effects of flow pattern and salinity of oil-water two-phase flow on water holdup measurement using a conductance method. Firstly, vertical upward oil-water two-phase flow experiment is conducted in a 20 mminner diameter (ID) pipe, in which the salinities of aqueous solutions are set as 151 ppm, 1003 ppm, 2494 ppm and 4991 ppm respectively. Experimental water-cut and mixture velocity are set as 80-100% and 0.0184-0.2576 m/s. In the experiment, three different flow patterns, i.e., dispersed oil-in-water slug flow (D OS/W), dispersed oil-in-water flow (D O/W) and very fine dispersed oil-in-water flow (VFD O/W) are observed and recorded by a high speed camera. Meanwhile, we collect the response of Vertical Multiple Electrode Array (VMEA) conductance sensor excited by a sine voltage signal. The result shows that, for VFD O/W, the water holdup from VMEA sensor shows a satisfied agreement with that of quick closing valve (QCV) method under certain salinities, i.e., 1003 ppm as well as 2494 ppm. For D OS/W flow and D O/W flow characterized by dispersed oil droplets with various sizes, considerable deviations of water holdup between VMEA sensor and QCV method under four kinds of salinity aforementioned are presented. Afterward, according to experimental analysis along with theoretical deviation, it is concluded that the deviation of the measurement system reaches its minimum when reference resistance in the measurement circuit and salinity of the aqueous solution satisfy constraint conditions, and the accuracy of water holdup using the conductance method can be improved through adjusting reference resistance to match the salinity of water phase. Finally, the recurrence plot algorithm is utilized to identify typical flow patterns mentioned above and it shows satisfied results on comprehending the discrepancies among different flow patterns, demonstrating that the recurrence plot algorithm can be effectively applied in flow pattern identification regarding oil-water flows. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:503 / 514
页数:12
相关论文
共 50 条
  • [1] Design of a Conductance and Capacitance Combination Sensor for water holdup measurement in oil-water two-phase flow
    Wu, Hao
    Tan, Chao
    Dong, Xiaoxiao
    Dong, Feng
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 46 : 218 - 229
  • [2] An on-line adaptive estimation method for water holdup measurement in oil-water two-phase flow with a conductance/capacitance sensor
    Wu, Hao
    Tan, Chao
    Dong, Feng
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (07)
  • [3] Water Holdup Measurement of Oil-Water Two-phase Flow Based on KPLS Regression
    Wang, Nana
    Tan, Chao
    Dong, Feng
    [J]. 2015 CHINESE AUTOMATION CONGRESS (CAC), 2015, : 1896 - 1900
  • [4] Water holdup measurement of oil-water two-phase flow in a horizontal well using a dual-circle conductance probe array
    Xu, Lijun
    Zhang, Wen
    Cao, Zhang
    Zhao, Jiayu
    Xie, Ronghua
    Liu, Xingbin
    Hu, Jinhai
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (11)
  • [5] Water holdup measurement of oil-water two-phase flow with low velocity using a coaxial capacitance sensor
    Chen, X.
    Han, Y. F.
    Ren, Y. Y.
    Zhang, H. X.
    Zhang, H.
    Jin, N. D.
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 81 : 244 - 255
  • [6] A New Method for Measuring Water Holdup of Oil-Water Two-Phase Flow in Horizontal Wells
    Wang, Yanjun
    Han, Jianlong
    Hao, Zhiqiang
    Zhou, Lijian
    Wang, Xinjie
    Shao, Mingwei
    [J]. PROCESSES, 2022, 10 (05)
  • [7] New Measurement Method of Oil-Water Two-Phase Flow with High Water Holdup and Low Rate by Phase State Regulation
    Han, Lianfu
    Chen, Ming
    Liu, Xingbin
    Fu, Changfeng
    [J]. MEASUREMENT SCIENCE REVIEW, 2023, 23 (06) : 268 - 274
  • [8] Liquid holdup measurement in horizontal oil-water two-phase flow by using concave capacitance sensor
    Zhao An
    Jin Ningde
    Zhai Lusheng
    Gao Zhongke
    [J]. MEASUREMENT, 2014, 49 : 153 - 163
  • [9] Measurement of Water Holdup in Vertical Upward Oil-Water Two-Phase Flow Pipes Using a Helical Capacitance Sensor
    Dai, Runsong
    Jin, Ningde
    Hao, Qingyang
    Ren, Weikai
    Zhai, Lusheng
    [J]. SENSORS, 2022, 22 (02)
  • [10] Measurement of the oil holdup for a two-phase oil-water flow through a sudden contraction in a horizontal pipe
    Colombo, L. P. M.
    Guilizzoni, M.
    Sotgia, G. M.
    Bortolotti, S.
    Pavan, L.
    [J]. 31ST UIT (ITALIAN UNION OF THERMO-FLUID-DYNAMICS) HEAT TRANSFER CONFERENCE 2013, 2014, 501