Novel non-targeted analysis of perfluorinated compounds using fluorine-specific detection regardless of their ionisability (HPLC-ICPMS/MS-ESI-MS)

被引:40
|
作者
Jamari, Nor Laili Azua [1 ]
Dohmann, Jan Frederik [1 ]
Raab, Andrea [1 ]
Krupp, Eva M. [1 ]
Feldmann, Jorg [1 ]
机构
[1] Univ Aberdeen, Dept Chem, Trace Element Speciat Lab TESLA, Aberdeen AB24 3UE, Scotland
基金
瑞典研究理事会;
关键词
Non-target method; ICPMS/MS; Polyatomic ion [BaF](+); Perfluoroalkyl substances; CHROMATOGRAPHY; WATER;
D O I
10.1016/j.aca.2018.11.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Although perfluorooctanesulfonic acid (PFOS) and perfluorooctanoic acid (PFOA) have been phased out, there is a plethora of per-or polyfluoroalkyl substances (PFAS) generated and only a small number of these compounds are currently being monitored in environmental and biological sample using molecular mass spectrometry (MS). Total fluorine determination has revealed that a substantial amount of fluorinated organic compounds has not been identified. Due to the small mass deficiency of fluorine, it is not an easy task to screen successfully all fluorinated compounds including those which are not easy ionisable, hence a novel fluorine-specific detector is needed. Here, inductively-coupled plasma mass spectrometry (ICPMS) was used for the first time for the detection of PFAS, by using the novel approach to transfer F- into a detectable [BaF](+) in the argon plasma. A reverse phase-high performance liquid chromatography (RP-HPLC) method was developed and then online coupled to ICPMS/MS for the fluorine-specific detection and simultaneously to electrospray MS (ESI-MS) to separate perfluorinated carboxylic acids (PFCA) and perfluorooctanesulfonic acid (PFOS). The calibration was linear and was element-specific with detection limits of 0.49mg F L-1 under gradient elution method. As a proof of concept, PFCA standards in methanol were not fully neutralised to force the esterification and those solutions were measured using HPLC-ICPMS/MS-ESI-MS. The methyl esters were not detectable by ESIMS but by ICPMS/MS. This illustrates that the undetectable fluorine-containing compounds were detected and quantified by the element-specific detection of ICPMS/MS. The analysis of spiked river water at sub-ppb level gave an acceptable recovery using a SPE-based preconcentration method. Since ICPMS/MS method is an element-specific detection, all non-fluorinated compounds interfering in ESI-MS were eliminated. Hence, HPLC-ICPMS/MS can be used as a non-targeted method of fluorinated compounds which helps the identification of novel fluorinated compounds in environmental and biological samples and helps with mining the ESI-MS data. (C) 2018 Published by Elsevier B.V.
引用
收藏
页码:22 / 31
页数:10
相关论文
共 9 条
  • [1] Novel non-target analysis of fluorine compounds using ICPMS/MS and HPLC-ICPMS/MS
    Jamari, N. Laili A.
    Dohmann, J. Frederik
    Raab, Andrea
    Krupp, Eva M.
    Feldmann, Joerg
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2017, 32 (05) : 942 - 950
  • [2] Sulphur fertilization influences the sulphur species composition in Allium sativum: sulphomics using HPLC-ICPMS/MS-ESI-MS/MS
    Raab, Andrea
    Ronzan, Marilena
    Feldmann, Joerg
    [J]. METALLOMICS, 2017, 9 (10) : 1429 - 1438
  • [3] Parallel and comparative non-targeted metabolomic speciation analysis of metalloids and their non-metal analogues by HPLC-ICPMS/MS in mushrooms
    Lajin, Bassam
    Braeuer, Simone
    Goessler, Walter
    [J]. METALLOMICS, 2021, 13 (08)
  • [4] Identification and characterization of isomeric intermediates in a catalyst formation reaction by means of speciation analysis using HPLC-ICPMS and HPLC-ESI-MS
    Tu, Q
    Wang, TB
    Welch, CJ
    Wang, P
    Jia, XJ
    Raab, C
    Bu, XD
    Bykowski, D
    Hohenstaufen, B
    Doyle, MP
    [J]. ANALYTICAL CHEMISTRY, 2006, 78 (04) : 1282 - 1289
  • [5] Identification of selenium compounds using HPLC-ICPMS and nano-ESI-MS in selenium-enriched rice via foliar application
    Fang, Yong
    Zhang, Yaofang
    Catron, Brittany
    Chan, Qilin
    Hu, Qiuhui
    Caruso, Joseph A.
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (12) : 1657 - 1664
  • [6] Fluorine-Specific Detection Using ICP-MS Helps to Identify PFAS Degradation Products in Nontargeted Analysis
    Heuckeroth, Steffen
    Nxumalo, Tengetile N.
    Raab, Andrea
    Feldmann, Joerg
    [J]. ANALYTICAL CHEMISTRY, 2021, 93 (16) : 6335 - 6341
  • [7] Chemical fingerprint and bioactivity evaluation of Globularia orientalis L. and Globularia trichosantha Fisch. & C. A. Mey. using non-targeted HPLC-ESI-QTOF-MS approach
    Rodriguez-Perez, Celia
    Zengin, Gokhan
    Segura-Carretero, Antonio
    Lobine, Devina
    Mahomoodally, Mohamad Fawzi
    [J]. PHYTOCHEMICAL ANALYSIS, 2019, 30 (02) : 237 - 252
  • [8] Comprehensive Non-Targeted Analysis of Contaminated Groundwater of a Former Ammunition Destruction Site using 1H-NMR and HPLC-SPE-NMR/TOF-MS
    Godejohann, Markus
    Heintz, Lea
    Daolio, Cristina
    Berset, Jean-Daniel
    Muff, Daniel
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (18) : 7055 - 7061
  • [9] Rapid discrimination of recycled and virgin poly(ethylene terephthalate) based on non-targeted screening of semi-volatile organic compounds using a novel method of DSI/GCxGC-Q-TOF-MS coupled with various chemometrics
    Hao, Tian-Ying
    Xu, Xiaowen
    Lin, Qin-Bao
    Wu, Si-Liang
    Wu, Xue-Feng
    Hu, Jia-Ling
    Zhong, Huai-Ning
    Dong, Ben
    Chen, Zhi-Feng
    Ye, Zhi-Kang
    Wang, Zhi-Wei
    [J]. FOOD PACKAGING AND SHELF LIFE, 2022, 34