The accuracy of femoral component rotational measurements using computed tomography-a cadaveric study

被引:2
|
作者
Eseonu, Onyedikachi [1 ]
Cree, Calum [2 ]
Sambrook, Martin [3 ]
Blyth, Mark [1 ]
Jones, Bryn [1 ]
机构
[1] Glasgow Royal Infirm, Dept Trauma & Orthopaed Surg, Castle St, Glasgow G4 0SF, Lanark, Scotland
[2] Dumfries & Galloway Royal Infirm, Dept Trauma & Orthopaed Surg, Dumfries DG2 8RX, Scotland
[3] Eastbourne Dist Gen Hosp, Dept Radiol, Kings Dr, Eastbourne BN21 2UD, England
关键词
Total knee arthroplasty; Total knee replacement; Rotation; Computed tomography; Cadaver; TOTAL KNEE ARTHROPLASTY; MALROTATION;
D O I
10.1186/s42836-020-00052-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundCT scans can be used to assess the rotational alignment of the femoral component following total knee arthroplasty (TKA). This is done by calculating the posterior condylar angle (PCA).However, the methods used may not account for the biomechanical functionality of the TKA components. This cadaveric study aimed to determine whether the axis of scanning (mechanical or anatomical) alters the results of PCA calculations.MethodsCT scans of 12 cadaveric adult femora were performed along the anatomical axis and the mechanical axis. The PCA was determined on each CT scan by measuring the relationship of the prosthetic posterior condyles to the surgical epicondylar axis of the femur. The mechanical and anatomical axis groups were further subdivided into best-fit and multi-slice subgroups. As a control, the posterior condylar angle was also calculated on photographic images of each femur. Bland-Altman plots were used to determine the correlation between the PCA values obtained from the different scanning axes and measurement techniques.ResultsThere was no significant difference between the PCA measurements derived from anatomical and mechanical axis CT scans. The Pearson correlation co-efficient also indicated good correlation between the two scanning axes.ConclusionThe axis of scanning does not significantly affect the PCA measurements. Therefore, the measurements may be reliably used for clinical decision-making, regardless of the axis of CT scanning.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] The accuracy of femoral component rotational measurements using computed tomography—a cadaveric study
    Onyedikachi Eseonu
    Calum Cree
    Martin Sambrook
    Mark Blyth
    Bryn Jones
    Arthroplasty, 2
  • [2] A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    Henrica M. J. van der Linden-van der Zwaag
    Janneke Bos
    Huub J. L. van der Heide
    Rob G. H. H. Nelissen
    International Orthopaedics, 2011, 35 : 845 - 850
  • [3] A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    van der Linden-van der Zwaag, Henrica M. J.
    Bos, Janneke
    van der Heide, Huub J. L.
    Nelissen, Rob G. H. H.
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (06) : 845 - 850
  • [4] Stature estimation based on femoral measurements in the modern Japanese population: a cadaveric study using multidetector computed tomography
    Chiba, Fumiko
    Makino, Yohsuke
    Torimitsu, Suguru
    Motomura, Ayumi
    Inokuchi, Go
    Ishii, Namiko
    Hoshioka, Yumi
    Abe, Hiroko
    Yamaguchi, Rutsuko
    Sakuma, Ayaka
    Nagasawa, Sayaka
    Saito, Hisako
    Yajima, Daisuke
    Fukui, Yuta
    Iwase, Hirotaro
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2018, 132 (05) : 1485 - 1491
  • [5] Stature estimation based on femoral measurements in the modern Japanese population: a cadaveric study using multidetector computed tomography
    Fumiko Chiba
    Yohsuke Makino
    Suguru Torimitsu
    Ayumi Motomura
    Go Inokuchi
    Namiko Ishii
    Yumi Hoshioka
    Hiroko Abe
    Rutsuko Yamaguchi
    Ayaka Sakuma
    Sayaka Nagasawa
    Hisako Saito
    Daisuke Yajima
    Yuta Fukui
    Hirotaro Iwase
    International Journal of Legal Medicine, 2018, 132 : 1485 - 1491
  • [6] Accuracy of Quantitative Computed Tomography Bone Mineral Density Measurements in Mandibles: A Cadaveric Study
    Miguel-Sanchez, Alfonso
    Vilaplana-Vivo, Jaime
    Vilaplana-Vivo, Carlos
    Angel Vilaplana-Gomez, Juan
    Camacho-Alonso, Fabio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 (04) : 693 - 699
  • [7] Morphological Study of Soft Palate by Using Computed Tomography-A Prospective Study
    More, Chandramani Bhagwan
    Saha, Nairita
    Vijayvargiya, Ritika
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2015, 9 (08) : ZC71 - ZC74
  • [8] Using the Axial Oblique View of Computed Tomography (CT) in Evaluating Femoral Anteversion: A Comparative Cadaveric Study
    Song, Kwang-Soon
    Yon, Chang-Jin
    Heo, Yu-Ran
    Lee, Jae-Ho
    Lee, Seung-Bo
    Ko, Yeon-Kyoung
    Lee, Kyung-Jae
    Lee, Si-Wook
    DIAGNOSTICS, 2022, 12 (08)
  • [9] Precision and accuracy for peripheral quantitative computed tomography evaluated using cadaveric radii
    Imai, Y
    Sone, T
    Mikawa, Y
    Watanabe, R
    Fukunaga, M
    JOURNAL OF CLINICAL DENSITOMETRY, 1998, 1 (02) : 165 - 172
  • [10] The accuracy of computed tomography for determining femoral and tibial total knee arthroplasty component rotation
    Jazrawi, LM
    Birdzell, L
    Kummer, FJ
    Di Cesare, PE
    JOURNAL OF ARTHROPLASTY, 2000, 15 (06): : 761 - 766