Theoretical and practical considerations on detection performance of time domain, Fourier domain, and swept source optical coherence tomography

被引:76
|
作者
Liu, Bin
Brezinski, Mark E.
机构
[1] Brigham & Womens Hosp, Dept Orthoped Surg, Boston, MA 02115 USA
[2] Harvard Med Sch, Boston, MA 02115 USA
关键词
optical coherence tomography; noise; dynamic range; quantum noise; plaque rupture; osteoarthritis;
D O I
10.1117/1.2753410
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Optical coherence tomography (OCT) based on spectral interferometry has recently been examined, with authors often suggesting superior performance compared with time domain approaches. The technologies have similar resolutions and the spectral techniques may currently claim faster acquisition rates. Contrary to many current opinions, their detection parameters may be inferior. The dynamic range and signal-to-noise ratio (SNR) correlate with image penetration, the contrast as a function of depth. This work examines the theoretical sensitivity, dynamic range, and SNR of the techniques, within the practical limits of optoelectronics, taking into account often ignored or misunderstood classical factors that affect performance, such as low frequency noise, analog to digital (AD) conversion losses, and methods for potentially improving sensitivity, including fast laser sweeping. The technologies are compared relative to these parameters. While Fourier domain OCT has some advantages such as signal integration, it appears unlikely that its disadvantages can ultimately be overcome for nontransparent tissue. Ultimately, time-domain (TD)-OCT appears to have the superior performance with respect to SNR and dynamic range. This may not be the case for transparent tissue of the eye. Certain positive aspects of swept source OCT leave the possibility open that its performance may approach that of (TD)-OCT in nontransparent tissue. (C) 2007 Society of Photo-Optical Instrumentation Engineers.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Theoretical and practical considerations on detection performance of time domain, Fourier domain, and swept source optical coherence tomography
    Brigham and Women's Hospital, Department of Orthopedic Surgery, 75 Francis Street, Boston, MA 02115, United States
    不详
    J Biomed Opt, 2007, 4
  • [2] Noise sources and optoelectronics which affect axial detection performance of time domain, Fourier domain and swept source optical coherence tomography
    Liu, Bin
    Brezinski, Mark E.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [3] Swept source at 1060 nm for Fourier domain optical coherence tomography
    Zhang, Jun
    Wang, Qiang
    Rao, Bin
    Chen, Zhongping
    Hsu, Kevin
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE XI, 2007, 6429
  • [4] Sensitivity advantage of swept source and Fourier domain optical coherence tomography
    Choma, MA
    Sarunic, MV
    Yang, CH
    Izatt, JA
    OPTICS EXPRESS, 2003, 11 (18): : 2183 - 2189
  • [5] Swept laser source at 1 μm for Fourier domain optical coherence tomography
    Zhang, Jun
    Wang, Qiang
    Rao, Bin
    Chen, Zhongping
    Hsu, Kevin
    APPLIED PHYSICS LETTERS, 2006, 89 (07)
  • [6] Performance of fourier domain vs. time domain optical coherence tomography
    Leitgeb, R
    Hitzenberger, CK
    Fercher, AF
    OPTICS EXPRESS, 2003, 11 (08): : 889 - 894
  • [7] Doppler Velocity Detection Limitations in Spectrometer and Swept-Source Fourier-Domain Optical Coherence Tomography
    Hendargo, Hansford C.
    McNabb, Ryan P.
    Dhalla, Al-Hafeez
    Shepherd, Neal
    Izatt, Joseph A.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [8] Swept source based Fourier domain functional optical coherence tomograph
    Zhang, Jun
    Rao, Bin
    Chen, Zhongping
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 7230 - 7233
  • [9] Multiband swept laser source for frequency domain optical coherence tomography
    Jiang, Junfeng
    Hui, Rongqing
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIV, 2010, 7554
  • [10] Swept source/Fourier domain polarization sensitive optical coherence tomography with a passive polarization delay unit
    Baumann, Bernhard
    Choi, WooJhon
    Potsaid, Benjamin
    Huang, David
    Duker, Jay S.
    Fujimoto, James G.
    OPTICS EXPRESS, 2012, 20 (09):