Flow cytometry and fluorescence in situ hybridization are methods of choice for routine diagnosis of mantle cell lymphoma.

被引:1
|
作者
Rymkiewicz, G
Woroniecka, R
Blachnio, K
Pienkowska-Grela, B
Walewski, J
机构
[1] Maria Sklodowska Curie Mem Inst Oncol, Ctr Oncol, Cytogenet Lab, Warsaw, Poland
[2] Maria Sklodowska Curie Mem Inst Oncol, Ctr Oncol, Hematooncol Intens Care Dept, Warsaw, Poland
[3] Maria Sklodowska Curie Mem Inst Oncol, Ctr Oncol, Dept Pathol, Warsaw, Poland
关键词
D O I
10.1182/blood.V106.11.4659.4659
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
4659
引用
收藏
页码:244B / 244B
页数:1
相关论文
共 50 条
  • [1] Fluorescence in situ hybridization: Method of choice for a definitive diagnosis of mantle cell lymphoma
    Sun, T
    Nordberg, ML
    Cotelingam, JD
    Veillon, DM
    Ryder, J
    AMERICAN JOURNAL OF HEMATOLOGY, 2003, 74 (01) : 78 - 84
  • [2] Banded chromosomes vs Fluorescence In Situ Hybridization (FISH) in the diagnosis of Mantle cell lymphoma.
    Mohamed, AN
    Ali, W
    Koppitch, F
    Alkatib, A
    AMERICAN JOURNAL OF HUMAN GENETICS, 2001, 69 (04) : 234 - 234
  • [3] Diagnostic utility of fluorescence in situ hybridization in mantle-cell lymphoma
    Remstein, ED
    Kurtin, PJ
    Buño, I
    Bailey, RJ
    Proffitt, J
    Wyatt, WA
    Hanson, CA
    Dewald, GW
    BRITISH JOURNAL OF HAEMATOLOGY, 2000, 110 (04) : 856 - 862
  • [4] Contribution of flow cytometry in the diagnosis of Hodgkin lymphoma.
    Goffinet, C
    Chatelain, C
    Cornet, Y
    Dromelet, A
    Chatelain, B
    CLINICAL CHEMISTRY, 2002, 48 (06) : A157 - A157
  • [5] Banded chromosomes versus fluorescence in situ hybridization in the diagnosis of mantle cell lymphoma: a lesson from three cases
    Mohamed, AN
    Ali, W
    Kopptich, F
    al Katib, A
    CANCER GENETICS AND CYTOGENETICS, 2002, 136 (02) : 108 - 112
  • [6] The Diagnosis of Gastric Mucosa-associated Lymphoid Tissue Lymphoma by Flow Cytometry and Fluorescence in situ Hybridization of Biopsy Specimens
    Matsueda, Katsunori
    Omote, Sizuma
    Sakata, Masahiro
    Fujita, Isao
    Horii, Jouichiro
    Toyokawa, Tatsuya
    INTERNAL MEDICINE, 2018, 57 (08) : 1081 - 1086
  • [7] Telomere analysis by fluorescence in situ hybridization and flow cytometry
    Hultdin, M
    Grönlund, E
    Norrback, KF
    Eriksson-Lindström, E
    Just, T
    Roos, G
    NUCLEIC ACIDS RESEARCH, 1998, 26 (16) : 3651 - 3656
  • [8] Microfluidic fluorescence in situ hybridization and flow cytometry (μFlowFISH)
    Liu, Peng
    Meagher, Robert J.
    Light, Yooli K.
    Yilmaz, Suzan
    Chakraborty, Romy
    Arkin, Adam P.
    Hazen, Terry C.
    Singh, Anup K.
    LAB ON A CHIP, 2011, 11 (16) : 2673 - 2679
  • [9] Detection of aneuploidy by flow cytometry and fluorescence in situ hybridization in the diagnosis of malignant pleural effusion
    Rosolen, D.
    Dutra, A. R. N.
    Bottura, G.
    da Silva, V. M.
    Capelozzi, V. L.
    Vargas, F. S.
    Antonangelo, L.
    VIRCHOWS ARCHIV, 2014, 465 : S295 - S296
  • [10] Secondary chromosome changes in mantle cell lymphoma: Cytogenetic and fluorescence in situ hybridization studies
    Bigoni, R
    Cuneo, A
    Milani, R
    Roberti, MG
    Bardi, A
    Rigolin, GM
    Cavazzini, F
    Agostini, P
    Castoldi, G
    LEUKEMIA & LYMPHOMA, 2001, 40 (5-6) : 581 - 590