Bar and Point Test Patterns Generated by Dry-Etching for Measurement of High Spatial Resolution in Micro-CT

被引:0
|
作者
Langner, O. [1 ]
Karolczak, M. [1 ]
Rattmann, G. [2 ]
Kalender, W. A. [1 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, Henkestr 91, Erlangen, Germany
[2] Fraunhofer Inst Integrated Syst & Device Technol, Erlangen, Germany
关键词
Micro-CT; MTF; spatial resolution; bar pattern; dry-etching;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work was to evaluate a novel method for manufacturing test patterns with high spatial resolution to be used for visual inspection of spatial resolution of micro-CT systems. High resolution test patterns of less than 50 mu m line widths or point diameter for inspection of the performance of a micro-CT system have not been reported before. Test patterns were created on a silicon wafer using a dry-etching method. For reference spatial resolution measurements were carried out on micro-CT systems using thin tungsten wires. The modulation transfer function (MTF) subsequently derived from a point spread function (PSF) of the wire profile was measured to determine spatial resolution at 10% of the contrast ratio. The test pattern chip was scanned under the same conditions for visual inspection of the spatial resolution. The results of the wire-based MTF calculations and visual inspection of the test patterns were found in very good agreement. In the manufacturing process some limitations were found due to over-etching and maximum etch depth for smaller patterns (5 mu m) adjacent to larger structures (150 mu m) on one chip. Nevertheless, these circumstances can be solved by using choice of pattern sizes for specific scanner setup. The novel method of creating high resolution test patterns for quick visual inspection offers a very attractive solution, but also allows for quantitative evaluation.
引用
下载
收藏
页码:428 / 431
页数:4
相关论文
共 6 条
  • [1] Measurement of spatial resolution of the micro-CT system
    Rong Jun-Yan
    Fu Guo-Tao
    Wei Cun-Feng
    Sun Cui-Li
    Wei Long
    CHINESE PHYSICS C, 2010, 34 (03) : 412 - 416
  • [2] Measurement of spatial resolution of the micro-CT system
    戎军艳
    付国涛
    魏存峰
    孙翠丽
    魏龙
    Chinese Physics C, 2010, (03) : 412 - 416
  • [3] Improving Spatial-Resolution in High Cone-Angle Micro-CT by Source Deblurring
    Li, Heyang
    Kingston, Andrew
    Myers, Glenn
    Recur, Benoit
    Turner, Michael
    Sheppard, Adrian
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [4] Study of 20 Hz high spatial-temporal resolution monochromatic X-ray dynamic micro-CT
    Qiu Z.
    Li K.
    Xie H.
    Du G.
    Deng B.
    Xiao T.
    He Jishu/Nuclear Techniques, 2023, 46 (07):
  • [5] High resolution three-dimensional imaging and measurement of lung, heart, liver, and diaphragmatic development in the fetal rat based on micro-computed tomography (micro-CT)
    Markel, Moritz
    Ginzel, Marco
    Peukert, Nicole
    Schneider, Hartmut
    Haak, Rainer
    Mayer, Steffi
    Suttkus, Anne
    Lacher, Martin
    Kluth, Dietrich
    Gosemann, Jan-Hendrik
    JOURNAL OF ANATOMY, 2021, 238 (04) : 1042 - 1054
  • [6] High-Spatial-Resolution Three-dimensional Imaging of Human Spinal Cord and Column Anatomy with Postmortem X-ray Phase-Contrast Micro-CT
    Barbone, Giacomo E.
    Bravin, Alberto
    Mittone, Alberto
    Grosu, Sergio
    Ricke, Jens
    Cavaletti, Guido
    Djonov, Valentin
    Coan, Paola
    RADIOLOGY, 2021, 298 (01) : 135 - 146