Output Impedance Modeling of Single-Phase Grid-Tied Inverters With Capturing the Frequency-Coupling Effect of PLL

被引:43
|
作者
Qian, Qiang [1 ]
Xie, Shaojun [1 ]
Xu, Jinming [1 ]
Xu, Kunshan [1 ]
Bian, Shenyiyang [1 ]
Zhong, Nini [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Nanjing 211106, Peoples R China
基金
中国国家自然科学基金;
关键词
Frequency-coupling effect; grid-tied inverters; harmonic; output impedance; phase-locked loop (PLL); STABILITY ANALYSIS; CONVERTERS; SYSTEMS;
D O I
10.1109/TPEL.2019.2946984
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The output impedance model for the precise stability analysis on the single-phase grid-tied inverters considering the frequency-coupling effect of the phase-locked loop (PLL) is studied. A multifrequency admittance matrix (MAM) is developed to predict the inverter-grid system stability by applying the generalized Nyquist criterion. Based on the MAM, a novel output impedance model characterized by clear physical meaning is proposed, which reveals that the inverter output impedance varies along with the grid impedance and the current reference . The resonance and the stability problems can be identified by applying the impedance-based stability criterion to the impedance ratio. The proposed impedance model is further extended to the <italic>n</italic>-parallel inverter system. It is found that the output impedances of two <italic>n</italic>-parallel homogeneous-inverter systems are identical if the number <italic>n</italic> and the total injected current <italic>i</italic>tot are the same, and the system stability is indicated by the impedance ratio , where is the output impedance of one special inverter with the average current <italic>i</italic>tot& x002F;<italic>n</italic> injected to the grid with. Further on, the design procedure of the PLL bandwidth is elaborated, which guides the selection of with the anticipated phase margin. Compared to the conventional impedance model, the developed output impedance is more qualified to precisely identify the harmonic stability problem in the weak grid. The selection of and the correctness of the proposed impedance model are experimentally verified by the measured output impedance and the waveforms of the elaborated cases.
引用
收藏
页码:5479 / 5495
页数:17
相关论文
共 50 条
  • [1] Impact of the Grid Impedance on the Single-Phase Grid-Tied Inverter Output Impedance Concerning the Frequency-Coupling Effect of the PLL
    Qian, Qiang
    Zhong, Nini
    Xie, Shaojun
    Xu, Jinming
    Zhang, Binfeng
    [J]. 45TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2019), 2019, : 2383 - 2388
  • [2] Frequency Coupling Suppression Control Strategy for Single-Phase Grid-Tied Inverters in Weak Grid
    Lin, Jianheng
    Su, Mei
    Sun, Yao
    Yang, Dongsheng
    Xie, Shiming
    Xiong, Wenjing
    Zhang, Guanguan
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2022, 69 (09) : 8926 - 8938
  • [3] A Synchronization Method for Single-Phase Grid-Tied Inverters
    Hadjidemetriou, Lenos
    Kyriakides, Elias
    Yang, Yongheng
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) : 2139 - 2149
  • [4] Modeling the Output Impedance Negative Incremental Resistance Behavior of Grid-Tied Inverters
    Wen, Bo
    Boroyevich, Dushan
    Mattavelli, Paolo
    Burgos, Rolando
    Shen, Zhiyu
    [J]. 2014 TWENTY-NINTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2014, : 1799 - +
  • [5] Input Impedance Modeling of Single-Phase Voltage Source Rectifier With Consideration of Frequency-Coupling Effect
    Lin, Jianheng
    Su, Mei
    Xie, Shiming
    Sun, Yao
    Liu, Yonglu
    [J]. PROCEEDINGS OF THE 15TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2020), 2020, : 1949 - 1954
  • [6] A Simplified Reactive Power Control for Single-Phase Grid-Tied Photovoltaic Inverters
    Chang, Chia-Hsi
    Lin, Yu-Hui
    Chen, Yao-Ting
    Chen, Yaow-Ming
    Chang, Yung-Ruei
    [J]. 2013 TWENTY-EIGHTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2013), 2013, : 2793 - 2798
  • [7] A Synchronization Scheme for Single-Phase Grid-Tied Inverters under Harmonic Distortion and Grid Disturbances
    Hadjidemetriou, Lenos
    Kyriakides, Elias
    Yang, Yongheng
    Blaabjerg, Frede
    [J]. APEC 2016 31ST ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, 2016, : 3500 - 3507
  • [8] A Synchronization Scheme for Single-Phase Grid-Tied Inverters Under Harmonic Distortion and Grid Disturbances
    Hadjidemetriou, Lenos
    Yang, Yongheng
    Kyriakides, Elias
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (04) : 2784 - 2793
  • [9] Design and Implementation of Digital Phase Locked Loop for Single-Phase Grid-Tied PV Inverters
    Zhou, Zhongfu
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2018, 46 (14-15) : 1662 - 1671
  • [10] Single-Phase Grid-Tied Inverters: Guidelines for Smoother Connection and Suitable Control Structure
    Liston, Roner A., Jr.
    Carati, Emerson G.
    Cardoso, Rafael
    da Costa, Jean Patric
    Stein, Carlos M. O.
    [J]. 2016 12TH IEEE/IAS INTERNATIONAL CONFERENCE ON INDUSTRY APPLICATIONS (INDUSCON), 2016,