Low-cost air quality monitoring system design and comparative analysis with a conventional method

被引:5
|
作者
Jacob, Mbarndouka Taamte [1 ,2 ]
Michaux, Kountchou Noube [1 ]
Bertrand, Bodo [2 ]
Flore, Tchuente Siaka Yvette [1 ]
Nasser, Nducol [1 ]
Ruben, Folifack Signing Vitrice [1 ]
Line, Tagne Mogue Ruth [1 ]
Saidou [1 ,3 ]
机构
[1] Res Ctr Nucl Sci & Technol, Inst Geol & Min Res, POB 4110, Yaounde, Cameroon
[2] Univ Yaounde I, Fac Sci, Dept Phys, Lab Elect & Elect Syst, Yaounde, Cameroon
[3] Univ Yaounde I, Fac Sci, Nucl Phys Lab, POB 812, Yaounde, Cameroon
关键词
Air quality; Arduino; Low-cost sensors; Gent sampler; Comparative analysis; LABORATORY EVALUATION;
D O I
10.1007/s40095-021-00415-y
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper deals with the development of a portable electronic device that simultaneously measures toxic gases and suspended particles in real time. It is based on a microcontroller board and low-cost sensors including dust sensor, smoke sensor, liquefied petroleum gas sensor, carbon dioxide (CO2) sensor, carbon monoxide (CO) sensor, temperature, and humidity sensors. The proposed electronic device presents several advantages, namely low energy consumption, low-cost equipment, easily deployable in the field, real-time, and large number measurements of parameters (in situ). It can also send automatically alert information and transmit emergency calls to the supervisor if the concentration of measured pollutant (particulate matter PM2.5) is beyond the threshold WHO limit of 25 mu g/m(3). The proposed electronic device can also be used as an outdoor or indoor air quality monitoring system. Compared to WHO limits, all the values of the parameters measured are generally acceptable, except CO value which slightly exceeds the average threshold value allowed in workplaces. A comparative analysis of particulate matter concentrations obtained from the proposed prototype and a conventional method based on the GENT Stacked Filter Unit Sampler (reference method) is carried out by placing both devices on the same fixed sampling site and collecting data at the same time over a period of two months. A statistical analysis based on linear regression highlighted a good agreement between these two methods with R-2 = 0.8897. Furthermore, a reliability coefficient of 1.008 +/- 0.01 confirms the effectiveness of the proposed device.
引用
收藏
页码:873 / 884
页数:12
相关论文
共 50 条
  • [1] Low-cost air quality monitoring system design and comparative analysis with a conventional method
    Mbarndouka Taamté Jacob
    Kountchou Noubé Michaux
    Bodo Bertrand
    Tchuente Siaka Yvette Flore
    Nducol Nasser
    Folifack Signing Vitrice Ruben
    Tagne Mogue Ruth Line
    [J]. International Journal of Energy and Environmental Engineering, 2021, 12 : 873 - 884
  • [2] Design of a Low-Cost Air Quality Monitoring System Using Arduino and ThingSpeak
    Kelechi, Anabi Hilary
    Alsharif, Mohammed H.
    Agbaetuo, Chidumebi
    Ubadike, Osichinaka
    Aligbe, Alex
    Uthansakul, Peerapong
    Kannadasan, Raju
    Aly, Ayman A.
    [J]. CMC-COMPUTERS MATERIALS & CONTINUA, 2022, 70 (01): : 151 - 169
  • [3] Design of a Low-Cost Potato Quality Monitoring System
    Agrahari, Ayush
    Pande, Revant
    Sharma, Paawan
    Kaundal, Vivek
    [J]. INTELLIGENT COMMUNICATION, CONTROL AND DEVICES, ICICCD 2017, 2018, 624 : 1171 - 1176
  • [4] Low-cost Air Quality System for Urban Area Monitoring
    Firculescu, Adrian-Cosmin
    Tudose, Dan Stefan
    [J]. 2015 20TH INTERNATIONAL CONFERENCE ON CONTROL SYSTEMS AND COMPUTER SCIENCE, 2015, : 240 - 247
  • [5] Design of Low-Cost Autonomous Water Quality Monitoring System
    Rao, Aravinda S.
    Marshall, Stephen
    Gubbi, Jayavardhana
    Palaniswami, Marimuthu
    Sinnott, Richard
    Pettigrove, Vincent
    [J]. 2013 INTERNATIONAL CONFERENCE ON ADVANCES IN COMPUTING, COMMUNICATIONS AND INFORMATICS (ICACCI), 2013, : 14 - 19
  • [6] An Online Low-Cost System for Air Quality Monitoring, Prediction, and Warning
    Sharma, Rishi
    Saini, Tushar
    Kumar, Praveen
    Pathania, Ankush
    Chitineni, Khyathi
    Chaturvedi, Pratik
    Dutt, Varun
    [J]. DISTRIBUTED COMPUTING AND INTERNET TECHNOLOGY (ICDCIT 2020), 2020, 11969 : 311 - 324
  • [7] Design of a Low-Cost System for the Measurement of Variables Associated With Air Quality
    Martinez, Alain
    Hernandez-Rodriguez, Erik
    Hernandez, Luis
    Schalm, Olivier
    Gonzalez-Rivero, Rosa Amalia
    Alejo-Sanchez, Daniellys
    [J]. IEEE EMBEDDED SYSTEMS LETTERS, 2023, 15 (02) : 105 - 108
  • [8] Design and Implementation of a Low-Cost Portable Water Quality Monitoring System
    Kelechi, Anabi Hilary
    Alsharif, Mohammed H.
    Anya, Anya Chukwudi-eke
    Bonet, Mathias U.
    Uyi, Samson Aiyudubie
    Uthansakul, Peerapong
    Nebhen, Jamel
    Aly, Ayman A.
    [J]. CMC-COMPUTERS MATERIALS & CONTINUA, 2021, 69 (02): : 2405 - 2424
  • [9] Design of a Low-cost Air Quality Remote Monitoring System based on IOT and Sensor Sensitivity Validation
    Luis Vazquez-Vera, Jorge
    Espinosa-Calderon, Alejandro
    Diaz-Carmona, Javier
    Lopez-Farias, Rodrigo
    Yassmany Hernandez-Paniagua, Ivan
    [J]. PROCEEDINGS OF THE XXII 2020 IEEE INTERNATIONAL AUTUMN MEETING ON POWER, ELECTRONICS AND COMPUTING (ROPEC 2020), VOL 4, 2020,
  • [10] Low-Cost Urban Air Quality Monitoring with Mosaic
    Guan, Gaoyang
    Chen, Yuan
    Guo, Kai
    Gao, Yi
    Dong, Wei
    [J]. 2016 IEEE Conference on Computer Communications Workshops (INFOCOM WKSHPS), 2016,