High Accuracy Amperometric Sense and Control Circuit for Three-electrode Biosensors

被引:0
|
作者
Enache, Andrei [1 ]
Rusu, Ion [1 ]
Draghici, Florin [1 ]
Pristavu, Gheorghe [1 ]
Brezeanu, Gheorghe [1 ]
Enache, Florin [2 ]
机构
[1] Univ Politehn Bucuresti, Bucharest, Romania
[2] Mil Tech Acad, Bucharest, Romania
关键词
biosensor; potentiostat; amperometry; stability; frequency compensation;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
A system used for measuring the concentration of chemical compounds in fluids/solutions is designed, implemented and tested. The system comprises a Sense and Control Circuit formed with a potentiostat for three-electrode electrochemical cell (biosensor) biasing and a transimpedance amplifier for cell current processing. The stability of the potentiostat and the linearity of the transimpedance amplifier are theoretically and experimentally investigated. The high accuracy of the system is demonstrated by simulations and measurements. A comparison with a commercially available system is carried out.
引用
收藏
页码:295 / 308
页数:14
相关论文
共 50 条
  • [1] Experimental Characterization of a High Accuracy Amperometric Sense and Control Circuit for Three-Electrode Biosensors
    Enache, Andrei
    Rusu, Ion
    Bucur, Bogdan
    Draghici, Florin
    Pristavu, Gheorghe
    Bucur, Madalina-Petruta
    Enache, Florin
    Brezeanu, Gheorghe
    [J]. 2017 INTERNATIONAL SEMICONDUCTOR CONFERENCE (CAS), 40TH EDITION, 2017, : 179 - 182
  • [2] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    TENG YuanJie
    Research Center of Analysis Test
    [J]. Science China Chemistry, 2010, (12) : 2581 - 2586
  • [3] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    YuanJie Teng
    Chen Chen
    ChangXiang Zhou
    HongLi Zhao
    MinBo Lan
    [J]. Science China Chemistry, 2010, 53 : 2581 - 2586
  • [4] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    Teng YuanJie
    Chen Chen
    Zhou ChangXiang
    Zhao HongLi
    Lan MinBo
    [J]. SCIENCE CHINA-CHEMISTRY, 2010, 53 (12) : 2581 - 2586
  • [5] Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system
    TENG YuanJieCHEN ChenZHOU ChangXiangZHAO HongLi LAN MinBo Shanghai key Laboratory of Functional Materials Chemistry
    Research Center of Analysis TestEast China University of Science and TechnologyShanghai China
    [J]. Science China(Chemistry)., 2010, 53 (12) - 2586
  • [6] Current-Mirror-Based Potentiostats for Three-Electrode Amperometric Electrochemical Sensors
    Ahmadi, Mohammad Mahdi
    Jullien, Graham A.
    [J]. IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, 2009, 56 (07) : 1339 - 1348
  • [7] Composite electrochemical biosensors:: a comparison of three different electrode matrices for the construction of amperometric tyrosinase biosensors
    Serra, B
    Jiménez, S
    Mena, ML
    Reviejo, AJ
    Pingarrón, JM
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (03): : 217 - 226
  • [8] Three-electrode CO2-laser with a middle control electrode
    Borovkov, VV
    Voronov, SL
    Lazhintsev, BV
    Nor-Arevyan, VA
    Feodorov, GI
    [J]. GAS AND CHEMICAL LASERS AND INTENSE BEAM APPLICATIONS, 1998, 3268 : 314 - 318
  • [9] Reliability and accuracy of measured overpotential in a three-electrode fuel cell system
    S.H. Chan
    X.J. Chen
    K.A. Khor
    [J]. Journal of Applied Electrochemistry, 2001, 31 : 1163 - 1170
  • [10] Reliability and accuracy of measured overpotential in a three-electrode fuel cell system
    Chan, SH
    Chen, XJ
    Khor, KA
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2001, 31 (10) : 1163 - 1170