Applicability of multisyringe chromatography coupled to on-line solid-phase extraction to the simultaneous determination of dicamba, 2,4-D, and atrazine

被引:14
|
作者
Chavez-Moreno, C. A. [1 ]
Guzman-Mar, J. L. [1 ]
Hinojosa-Reyes, L. [1 ]
Hernandez-Ramirez, A. [1 ]
Ferrer, L. [2 ]
Cerda, V. [2 ]
机构
[1] UANL, Fac Ciencias Quim, San Nicolas De Los Garza 66451, Nuevo Leon, Mexico
[2] Univ Balearic Isl, Dept Chem, Palma De Mallorca 07122, Spain
关键词
Herbicides; Multisyringe chromatography; On-line solid-phase extraction; Monolithic column; Environmental analysis; FLOW-INJECTION; MONOLITHIC COLUMN; PESTICIDES; HERBICIDES; TRIAZINES;
D O I
10.1007/s00216-012-6055-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Simultaneous determination of three herbicides (dicamba, 2,4-D, and atrazine) has been achieved by on-line solid-phase extraction (SPE) coupled to multisyringe chromatography (MSC) with UV detection. The preconcentration conditions were optimized; a preconcentration flow rate of 0.5 mL min(-1) and elution at 0.8 mL min(-1) were the optimum conditions. A C-18 (8 mm i.d.) membrane extraction disk conditioned with 0.3 mol L-1 HCl in 0.5 % MeOH was used. A 3-mL sample was preconcentrated, then eluted with 0.43 mL 40:60 water-MeOH. A C-18 monolithic column (25 mm x 4.6 mm) was used for chromatographic separation. Separation of the three compounds was achieved in 10 min by use of 0.01 % aqueous acetic acid-MeOH (60:40) as mobile phase at a flow rate of 0.8 mL min(-1). The limits of detection (LOD) were 13, 57, and 22 mu g L-1 for dicamba, 2,4-D, and atrazine, respectively. The sampling frequency was three analyses per hour, and each analysis consumed only 7.3 mL solvent. The method was applied to spiked water samples, and recovery between 85 and 112 % was obtained. Recovery was significantly better than in the conventional HPLC-UV method. These results indicated the reliability and accuracy of this flow-based method. This is the first time this family of herbicides has been simultaneously analyzed by on-line SPE-MSC using a monolithic column.
引用
收藏
页码:2705 / 2714
页数:10
相关论文
共 50 条
  • [1] Applicability of multisyringe chromatography coupled to on-line solid-phase extraction to the simultaneous determination of dicamba, 2,4-D, and atrazine
    C. A. Chávez-Moreno
    J. L. Guzmán-Mar
    L. Hinojosa-Reyes
    A. Hernández-Ramírez
    L. Ferrer
    V. Cerdà
    Analytical and Bioanalytical Chemistry, 2012, 403 : 2705 - 2714
  • [2] On-line monitoring of the photocatalytic degradation of 2,4-D and dicamba using a solid-phase extraction-multisyringe flow injection system
    Chavez-Moreno, Carmin
    Ferrer, Laura
    Hinojosa-Reyes, Laura
    Hernandez-Ramirez, Aracely
    Cerda, Victor
    Guzman-Mar, Jorge
    JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2013, 129 : 377 - 383
  • [3] Atrazine and 2, 4-D Determination in Corn Samples Using Microwave Assisted Extraction and On-line Solid-phase Extraction Coupled to Liquid Chromatography
    Susana Santos-Hernandez, Ana
    Hinojosa-Reyes, Laura
    del Carmen Saenz-Tavera, Isabel
    Hernandez-Ramirez, Aracely
    Luis Guzman-Mar, Jorge
    JOURNAL OF THE MEXICAN CHEMICAL SOCIETY, 2018, 62 (02) : 282 - 294
  • [4] Automated solid-phase extraction on-line coupled to gas chromatography
    Enoch, P
    Putzler, A
    Rinne, D
    Schlüter, J
    JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (01) : 75 - 82
  • [5] Simultaneous determination of caffeine, theophylline and theobromine in human plasma by on-line solid-phase extraction coupled to reversed-phase chromatography
    Emara, S
    BIOMEDICAL CHROMATOGRAPHY, 2004, 18 (08) : 479 - 485
  • [6] ANALYSIS OF RIVER WATER FOR THE HERBICIDES 2,4-D AND DICAMBA BY SOLID-PHASE EXTRACTION, DERIVATIZATION, AND GAS-CHROMATOGRAPHY - MASS-SPECTROMETRY
    ZIMMERMAN, LR
    THURMAN, EM
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 13 - ENVR
  • [7] Determination of sulfonamides in serum by on-line solid-phase extraction coupled to liquid chromatography with photoinduced fluorescence detection
    Arroyo-Manzanares, Natalia
    Lara, Francisco J.
    Airado-Rodriguez, Diego
    Gamiz-Gracia, Laura
    Garcia-Campana, Ana M.
    TALANTA, 2015, 138 : 258 - 262
  • [8] On-line solid-phase extraction and high performance liquid chromatography for the determination of bromide
    Jain, A
    Mishra, S
    Sahasrabuddhey, B
    Verma, KK
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 1997, 36 (10): : 908 - 912
  • [9] Solid-phase extraction or liquid chromatography coupled on-line with gas chromatography in the analysis of biological samples
    Hyötyläinen, T
    Riekkola, ML
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (01): : 13 - 21
  • [10] Simultaneous determination of 2,4-D, dicamba, and mecoprop in soil leachates by gas chromatography with electron capture detection
    Hong, MK
    Kim, MC
    Smith, AE
    JOURNAL OF AOAC INTERNATIONAL, 1996, 79 (04) : 998 - 1004