Performance Evaluation of Copper and Stainless-steel Electrodes in Electrical Tomographic Imaging

被引:7
|
作者
Akingboye, Adedibu Sunny [1 ,2 ]
Bery, Andy Anderson [1 ]
机构
[1] Univ Sains Malaysia, Sch Phys, George Town 11800, Malaysia
[2] Adekunle Ajasin Univ, Dept Earth Sci, Akungba Akoko 001, Ondo State, Nigeria
关键词
electrical resistivity tomography; induced polarisation; percentage relative differences; electrodes performance evaluation; land uses; INDUCED POLARIZATION; RESISTIVITY;
D O I
10.21315/jps2021.32.3.2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Geophysicists use electrical methods to investigate and characterise the earth's subsurface geology. This study aims to evaluate the performance of copper and conventional stainless-steel electrodes in subsurface tomographic investigations using electrical resistivity tomography (ERT) and induced polarisation (IP) at two sites in Penang, Malaysia. Site 1 and Site 2 employed profile lengths of 200 m and 100 m, with electrodes spacing of 5.0 m and 2.5 m, respectively. In the results of the final data inversion, it was observed that the ERT and IP tomographic models of Site 1 have the best convergence limits with percentage relative differences (copper as reference model) ranging from -70% to 70%, while Site 2 recorded -8% to 8%. The electrodes performance evaluation showed that population root mean square (RMS) error and population mean absolute percentage error (MAPE) of data points between copper and stainless-steel electrodes yielded large values for Site 1 with values above 28% and that of Site 2 was less than 4%. Hence, copper (good electrical conductivity and non-polarisable) electrodes have improved the quality and quantity of infield data which give low values of population RMS error and population MAPE compared to conventional stainless-steel electrodes, especially for large unit electrode spacing surveys. Most notably, this work has contributed to the understanding of the capability of copper electrodes in providing precise and reliable inversion models for subsurface tomographic investigations in pre- and post-land uses (engineering work), hydrogeologv/groundwater, environmental studies, etc.
引用
收藏
页码:13 / 29
页数:17
相关论文
共 50 条
  • [1] ELECTRICAL BREAKDOWN BETWEEN STAINLESS-STEEL ELECTRODES IN VACUUM
    VANOOSTROM, A
    AUGUSTUS, L
    VACUUM, 1982, 32 (03) : 127 - 135
  • [2] PERFORMANCE OF COPPER ELECTROPLATING OF STAINLESS-STEEL SHEETS
    RIZK, M
    TALAT, DA
    METALL, 1989, 43 (08): : 727 - 731
  • [3] IMPEDANCE OF STAINLESS-STEEL ELECTRODES
    GEDDES, LA
    DACOSTA, CP
    WISE, G
    MEDICAL & BIOLOGICAL ENGINEERING, 1971, 9 (05): : 511 - &
  • [4] AREA EFFECT ON ELECTRIC BREAKDOWN OF COPPER AND STAINLESS-STEEL ELECTRODES IN VACUUM
    OKAWA, M
    SHIOIRI, T
    OKUBO, H
    YANABU, S
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1988, 23 (01): : 77 - 81
  • [5] SURFACING WITH STAINLESS-STEEL STRIP ELECTRODES
    BERNSTEIN, A
    BACKMAN, A
    ARESKOUG, M
    FORSBERG, S
    WELDING JOURNAL, 1975, 54 (09) : 647 - 655
  • [6] ELECTRICAL BREAKDOWN BETWEEN STAINLESS-STEEL AND MOLYBDENUM ELECTRODES IN HIGH-VACUUM
    SINHA, MK
    KU, YG
    JOHNSON, RP
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (03): : 450 - 451
  • [7] ELECTRICAL BREAKDOWN PROPERTIES OF STAINLESS-STEEL AND TITANIUM ELECTRODES IN ULTRAHIGH-VACUUM
    BEUKEMA, GP
    PHYSICA B & C, 1981, 103 (2-3): : 397 - 411
  • [8] INVIVO MEASUREMENT OF ELECTRICAL PARAMETERS WITH ALUMINA-COVERED STAINLESS-STEEL ELECTRODES
    ESCUDERO, ML
    RUIZ, J
    GONZALEZ, JA
    RUIZ, J
    BIOMATERIALS, 1986, 7 (03) : 197 - 200
  • [9] EVALUATION OF DIRECT BLADDER STIMULATION WITH STAINLESS-STEEL WOVEN EYE ELECTRODES
    WALTER, JS
    WHEELER, JS
    COGAN, SF
    PLISHKA, M
    RIEDY, LW
    WURSTER, RD
    JOURNAL OF UROLOGY, 1993, 150 (06): : 1990 - 1996
  • [10] NOISE CHARACTERISTICS OF STAINLESS-STEEL SURFACE ELECTRODES
    GODIN, DT
    PARKER, PA
    SCOTT, RN
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (06) : 585 - 590